{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:50:09Z","timestamp":1787071809072,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T00:00:00Z","timestamp":1765497600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>This study aimed to evaluate the effect of fluorescein on intraocular pressure (IOP) measurements using Goldmann applanation tonometry (GAT). The study compared IOP readings with and without fluorescein to determine its influence on measurement accuracy in clinical practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This cross-sectional study included 39 patients (78 eyes). IOP was measured three times under each condition: fluorescein-free with green light and fluorescein-aided with cobalt blue light. The prespecified primary comparison was between the first fluorescein-free reading and the first fluorescein-aided reading, separated by approximately 1 minute (the time needed to apply fluorescein). Statistical analysis (repeated-measures ANOVA for within-series change; Wilcoxon signed-rank tests for paired comparisons) was used to compare measurements, while corneal astigmatism, keratometry, and central corneal thickness were assessed for their potential influence on discrepancies. A sensitivity analysis excluding patients with &gt;3.0 D corneal astigmatism was conducted.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      No significant difference was found between the first fluorescein-free and first fluorescein-aided IOP measurements (Wilcoxon\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.75; mean difference +0.04 mmHg). Consecutive measurements showed significant IOP reductions within each group, attributed to mechanical effects of the tonometer (repeated-measures ANOVA\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01). Corneal parameters, including central corneal thickness and keratometry, did not significantly affect the differences. Results were unchanged after excluding patients with &gt;3.0 D astigmatism.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Fluorescein does not significantly affect IOP measurements using GAT, supporting fluorescein-free measurement as a viable alternative in routine practice. Further research is needed to evaluate its application in cases of high astigmatism or altered corneal geometry.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_676_25","type":"journal-article","created":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T17:00:10Z","timestamp":1765558810000},"page":"93-97","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of intraocular pressure measurements with and without fluorescein using Goldmann applanation tonometry"],"prefix":"10.4103","volume":"74","author":[{"given":"Ante","family":"Kre\u0161o","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, University Hospital of Split, Spinciceva 1, Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nora","family":"Peri\u0161i\u0107","sequence":"additional","affiliation":[{"name":"Physical Medicine and Rehabilitation with Rheumatology, University Hospital of Split, Spinciceva 1, Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karla","family":"Kati\u0107","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital of Split, Spinciceva 1, Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anita","family":"Ran\u010di\u0107","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital of Split, Spinciceva 1, Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ljubo","family":"Znaor","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital of Split, Spinciceva 1, Split, Croatia"},{"name":"Science Department, University Hospital of Split, Spinciceva 1, Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,12]]},"reference":[{"key":"R1-20260420","doi-asserted-by":"crossref","first-page":"495","DOI":"10.4103\/ijo.IJO_1130_17","article-title":"Simplifying \u201ctarget\u201d intraocular pressure for different stages of primary open-angle glaucoma and primary angle-closure glaucoma","volume":"66","author":"Sihota","year":"2018","journal-title":"Indian J Ophthalmol"},{"key":"R2-20260420","first-page":"e11686","article-title":"Epidemiology of glaucoma: The past, present, and predictions for the future","volume":"12","author":"Allison","year":"2020","journal-title":"Cureus"},{"key":"R3-20260420","doi-asserted-by":"crossref","first-page":"101232","DOI":"10.1016\/j.preteyeres.2023.101232","article-title":"IOP and glaucoma damage: The essential role of optic nerve head and retinal mechanosensors","volume":"99","author":"Pitha","year":"2024","journal-title":"Prog Retin Eye Res"},{"key":"R4-20260420","first-page":"241","article-title":"[Differences in the measurement results of Goldmann applanation tonometry with and without fluorescein]","volume":"111","author":"Arend","year":"2014","journal-title":"Ophthalmol Z Dtsch Ophthalmol Ges"},{"key":"R5-20260420","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1097\/APO.0000000000000118","article-title":"Fundamentals and advances in tonometry","volume":"4","author":"Nuyen","year":"2015","journal-title":"Asia-Pac J Ophthalmol"},{"key":"R6-20260420","doi-asserted-by":"crossref","first-page":"e897","DOI":"10.1097\/IJG.0000000000000403","article-title":"Prospective comparative analysis of 4 different intraocular pressure measurement techniques and their effects on pressure readings","volume":"25","author":"Berk","year":"2016","journal-title":"J Glaucoma"},{"key":"R7-20260420","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1007\/s11596-011-0163-3","article-title":"Comparison of intraocular pressures at different points in human\u2019s cornea before and after laser in situ keratomileusis with tono-pen tonometer","volume":"31","author":"Li","year":"2011","journal-title":"J Huazhong Univ Sci Technolog Med Sci"},{"key":"R8-20260420","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.oftal.2010.09.003","article-title":"[Comparison of Goldmann tonometry, pneumotonometry and the effect of the central corneal thickness]","volume":"85","author":"Molina","year":"2010","journal-title":"Arch Soc Espanola Oftalmol"},{"key":"R9-20260420","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1097\/00006324-198112000-00008","article-title":"Goldmann applanation tonometry without fluorescein","volume":"58","author":"Bright","year":"1981","journal-title":"Am J Optom Physiol Opt"},{"key":"R10-20260420","doi-asserted-by":"crossref","first-page":"e1390","DOI":"10.1002\/hsr2.1390","article-title":"Analysis of goldman applanation tonometry with and without fluorescein among glaucomatous and nonglaucomatous patients attending Mzuzu Central Hospital in Malawi: A cross-sectional study","volume":"6","author":"Munyapa","year":"2023","journal-title":"Health Sci Rep"},{"key":"R11-20260420","doi-asserted-by":"crossref","first-page":"84","DOI":"10.5301\/ejo.5000325","article-title":"Red-free light for measurement of intraocular pressure using Goldmann applanation tonometer without fluorescein","volume":"24","author":"Ghoneim","year":"2014","journal-title":"Eur J Ophthalmol"},{"key":"R12-20260420","doi-asserted-by":"crossref","first-page":"2183","DOI":"10.2147\/OPTH.S177870","article-title":"A comparison of NCT, Goldman application tonometry values with and without fluorescein","volume":"12","author":"Erdogan","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R13-20260420","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/S0002-9394(14)75134-7","article-title":"Applanation tonometry with and without fluorescein","volume":"90","author":"Roper","year":"1980","journal-title":"Am J Ophthalmol"},{"key":"R14-20260420","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/0002-9394(58)90643-3","article-title":"On changes in intraocular pressure after application of the tonometer; in the same eye and in the other eye","volume":"45","author":"Stocker","year":"1958","journal-title":"Am J Ophthalmol"},{"key":"R15-20260420","first-page":"604","article-title":"[On spontaneous decrease of pressure in applanation tonometry]","volume":"151","author":"Bechrakis","year":"1966","journal-title":"Ophthalmol J Int Ophtalmol Int J Ophthalmol Z Augenheilkd"},{"key":"R16-20260420","doi-asserted-by":"crossref","first-page":"17864","DOI":"10.1038\/s41598-023-45165-5","article-title":"The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug","volume":"13","author":"Macedo","year":"2023","journal-title":"Sci Rep"},{"key":"R17-20260420","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/1752-1947-4-27","article-title":"Anaphylactic response to topical fluorescein 2% eye drops: A case report","volume":"4","author":"Shahid","year":"2010","journal-title":"J Med Case Rep"},{"key":"R18-20260420","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1093\/milmed\/167.11.956","article-title":"Systemic adverse reaction to topical fluorescein dye: A previously unreported event","volume":"167","author":"Anderson","year":"2002","journal-title":"Mil Med"},{"key":"R19-20260420","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1111\/j.1600-0536.1990.tb01504.x","article-title":"Photoallergic reaction to fluorescein","volume":"22","author":"Hochsattel","year":"1990","journal-title":"Contact Dermatitis"},{"key":"R20-20260420","doi-asserted-by":"crossref","first-page":"27762","DOI":"10.1038\/s41598-024-79394-z","article-title":"Safety reporting in trials on glaucoma interventions registered in ClinicalTrials.gov and corresponding publications","volume":"14","author":"Kre\u0161o","year":"2024","journal-title":"Sci Rep"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_676_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:56:33Z","timestamp":1787068593000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_676_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,12]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_676_25","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,12]]},"assertion":[{"value":"2025-03-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}