{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:34:05Z","timestamp":1786649645603,"version":"build-2736575974"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the visual outcomes and monocular defocus curve of a new monofocal Tecnis Eyhance IOL (Tecnis ICB00) with Tecnis 1 single piece (ZCB00).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Eighty patients diagnosed with cataract were divided into two groups: Tecnis ICB00 (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 40) and ZCB00 (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 40). The visual outcome was evaluated using the following parameters: uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity (DCIVA), corrected near visual acuity (CNVA), uncorrected visual acuity contrast sensitivity (UVACS), best-corrected visual acuity contrast sensitivity (BCVACS), manifest refraction, and defocus curve and was compared at the 6\n                      <jats:sup>th<\/jats:sup>\n                      week and 3 months after surgery.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The UIVA and UNVA were significantly (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05) better in ICB00 as compared with ZCB00 at 6 weeks and 3 months postoperative. The DCIVA was significantly better in ICB00 as compared with ZCB00 at 3 months postoperative (\u22120.015 \u00b1 0.04 vs. 0.01 \u00b1 0.020;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.01). Regarding contrast sensitivity, UVACS and BCVACS were significantly better in ICB00 as compared with ZCB00 at 6 weeks and 3 months postoperative (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). The defocus curves showed that the mean visual acuity of the ICB00 group was significantly better than that of the ZCB00 group at between \u2013 0.5 D and \u2013 2.50 D of defocus.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In patients undergoing cataract surgery, Eyhance ICB00 provided better intermediate vision as compared with ZCB00.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_681_23","type":"journal-article","created":{"date-parts":[[2024,1,26]],"date-time":"2024-01-26T03:00:19Z","timestamp":1706238019000},"page":"181-184","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":17,"title":["Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses"],"prefix":"10.4103","volume":"72","author":[{"given":"Gagandeep","family":"Singh","sequence":"first","affiliation":[{"name":"DNB Resident, Sankara Eye Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K S","family":"Sidhharthan","sequence":"additional","affiliation":[{"name":"Consultant, EyeMed Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jagadeesh K","family":"Reddy","sequence":"additional","affiliation":[{"name":"Cornea Department, Sankara Eye Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vandana","family":"Sundaram","sequence":"additional","affiliation":[{"name":"Cornea Department, Sankara Eye Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mithun","family":"Thulasidas","sequence":"additional","affiliation":[{"name":"Glaucoma Department, Sankara Eye Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,25]]},"reference":[{"key":"R1-20260428","doi-asserted-by":"crossref","first-page":"6762","DOI":"10.1167\/iovs.15-17201","article-title":"Number of people blind or visually impaired by cataract worldwide and in world regions, 1990 to 2010","volume":"56","author":"Khairallah","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R2-20260428","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1136\/bjophthalmol-2011-300539","article-title":"Global estimates of visual impairment: 2010","volume":"96","author":"Pascolini","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"R3-20260428","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.ophtha.2016.09.039","article-title":"Special report: American Academy of Ophthalmology Task Force consensus statement for extended depth of focus intraocular lenses","volume":"124","author":"MacRae","year":"2017","journal-title":"Ophthalmol"},{"key":"R4-20260428","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1136\/bjophthalmol-2015-308328","article-title":"Blindness, cataract surgery and mortality in Ethiopia","volume":"100","author":"Thomas","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R5-20260428","doi-asserted-by":"crossref","first-page":"228","DOI":"10.3928\/1081597X-20180125-01","article-title":"Visual performance of a new extended depth-of-focus intraocular lens compared to a distance-dominant diffractive multifocal intraocular lens","volume":"34","author":"Savini","year":"2018","journal-title":"J Refract Surg"},{"key":"R6-20260428","doi-asserted-by":"crossref","first-page":"e164","DOI":"10.1016\/j.ophtha.2020.09.026","article-title":"Multifocal and EDOF intraocular lenses in 2020","volume":"128","author":"Rampat","year":"2020","journal-title":"Ophthalmol"},{"key":"R7-20260428","article-title":"Delivering intermediate vision: The new TECNIS Eyhance Monofocal IOL","year":"2019","journal-title":"Ophthalmologist"},{"key":"R8-20260428","article-title":"Highlights from the Frankfurt January 2019 Advisory Board Meeting (2018) Material: \u2018\u201cDelivering intermediate vision: The new TECNIS eyhance monofocal IOL.\u201d\u2019"},{"key":"R9-20260428","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/j.jcrs.2008.04.031","article-title":"Optimising measurement of subjective amplitude of accommodation with defocus curves","volume":"34","author":"Gupta","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R10-20260428","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/j.jcrs.2013.01.031","article-title":"Exploring the optimum step size for defocus curves","volume":"39","author":"Wolffsohn","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260428","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1016\/S0886-3350(02)01317-2","article-title":"Comparison of visual acuities at different distances and defocus curves","volume":"28","author":"Pieh","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R12-20260428","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.clae.2007.02.005","article-title":"Is randomisation necessary for measuring defocus curves in pre-presbyopes?","volume":"30","author":"Gupta","year":"2007","journal-title":"Cont Lens Anterior Eye"},{"key":"R13-20260428","article-title":"Data on File","year":"2018"},{"key":"R14-20260428","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","article-title":"Dissatisfaction after implantation of multifocal intraocular lenses","volume":"37","author":"de Vries","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R15-20260428","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1097\/j.jcrs.0000000000000215","article-title":"Surface profiles of new-generation IOLs with improved intermediate vision","volume":"46","author":"Tognetto","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R16-20260428","doi-asserted-by":"crossref","first-page":"112","DOI":"10.3341\/kjo.2020.1115","article-title":"Visual performance and optical quality after implantation of a new generation monofocal intraocular lens","volume":"35","author":"Kang","year":"2021","journal-title":"Korean J Ophthalmol"},{"key":"R17-20260428","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/j.jcrs.0000000000000061","article-title":"Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: Preliminary results","volume":"46","author":"Mencucci","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R18-20260428","doi-asserted-by":"crossref","first-page":"3025","DOI":"10.4103\/ijo.IJO_985_20","article-title":"Comparison of an aspheric monofocal intraocular lens with the new generation monofocal lens using defocus curve","volume":"68","author":"Yangzes","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"R19-20260428","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/s10792-020-01599-8","article-title":"Vision outcomes with a new monofocal IOL","volume":"41","author":"Cinar","year":"2021","journal-title":"Int Ophthalmol"},{"key":"R20-20260428","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1186\/s12886-021-02124-w","article-title":"A comparison of clinical outcomes and optical performance between monofocal and new monofocal with enhanced intermediate function intraocular lenses: A case-control study","volume":"21","author":"Huh","year":"2021","journal-title":"BMC Ophthalmol"},{"key":"R21-20260428","doi-asserted-by":"crossref","first-page":"2285","DOI":"10.1007\/s42399-021-00988-z","article-title":"The evaluation of a new IOL with extended depth of focus to increase visual acuity for intermediate distance","volume":"3","author":"Ucar","year":"2021","journal-title":"SN Compr Clin Med"},{"key":"R22-20260428","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1186\/s12886-023-02920-6","article-title":"Comparison of visual performances of enhanced monofocal versus standard monofocal IOLs in a mini-monovision approach","volume":"23","author":"Beltraminelli","year":"2023","journal-title":"BMC Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_681_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:56:27Z","timestamp":1786647387000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_681_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,25]]},"references-count":22,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_681_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,25]]},"assertion":[{"value":"2023-03-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-08-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}