{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:46:39Z","timestamp":1789015599154,"version":"build-2803163510"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T00:00:00Z","timestamp":1740528000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess repeatability and agreement of Eyestar 900 (Haag-Streit, K\u00f6niz, Switzerland) with Pentacam AXL Wave system (Oculus, Wetzlar, Germany), Anterion (Heidelberg Engineering GmBH, Heidelberg, Germany), and MS-39 (CSO, Florence, Italy) in measuring anterior segment parameters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Two hundred normal eyes, 50 keratoconus (KC) eyes, and 50 post-refractive surgery eyes underwent three sequential scans on each instrument. The order of scans was randomized. Repeatability was assessed using within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC). Bland\u2013Altman analysis was used to assess the 95% limits of agreement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Eyestar 900 had comparable repeatability to Anterion and MS-39 across groups. ICC was overall &gt;0.8. Pentacam AXL Wave had lower Sw (better repeatability) across all groups. In normal eyes, Eyestar 900 can be used interchangeably with MS-39 and Anterion (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.23). Eyestar 900 and Pentacam AXL Wave did not show agreement on any parameter, except anterior chamber depth (ACD) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.92). Eyestar 900 in KC eyes can be used interchangeably with MS-39, except for posterior keratometry (pK) and thinnest corneal thickness (TCT) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and with Anterion, except for TCT and ACD (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). In post-refractive eyes, Eyestar 900 can be used interchangeably with MS-39, except for pK (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and with Anterion, except for ACD (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Pentacam AXL Wave and Eyestar 900 cannot be used interchangeably in KC and post-refractive eyes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Newer devices such as Eyestar 900 can be used interchangeably with Anterion and MS-39 in normal eyes and partly in KC and post-refractive eyes. Pentacam AXL Wave and Eyestar 900 cannot be used interchangeably across the various groups. However, these multifunctional hybrid tools of combined topography, AS-OCT, can be helpful in refractive clinics.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_805_24","type":"journal-article","created":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T03:05:02Z","timestamp":1740539102000},"page":"325-334","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Repeatability and agreement of a new anterior segment optical coherence tomography with standard devices in normal, keratoconus, and post-refractive eyes"],"prefix":"10.4103","volume":"73","author":[{"given":"Gairik","family":"Kundu","sequence":"first","affiliation":[{"name":"Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naren","family":"Shetty","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Durgalaxmi","family":"Modak","sequence":"additional","affiliation":[{"name":"Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luci","family":"Kaweri","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Surgery, ASG Eye Hospital, Mysore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pooja","family":"Khamar","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Arora","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Surgery, Aro Health, Gurugram, Haryana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rudy M M A","family":"Nuijts","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Maastricht University Medical Center, Maastricht, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit","family":"Shetty","sequence":"additional","affiliation":[{"name":"Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,26]]},"reference":[{"key":"R1-20260422","doi-asserted-by":"crossref","first-page":"5499","DOI":"10.1167\/iovs.07-0591","article-title":"Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography","volume":"48","author":"Mohamed","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R2-20260422","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.preteyeres.2018.04.002","article-title":"Anterior segment optical coherence tomography","volume":"66","author":"Ang","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"R3-20260422","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1111\/cxo.12937","article-title":"Customised aberration-controlling corrections for keratoconic patients using contact lenses","volume":"103","author":"Jinabhai","year":"2020","journal-title":"Clin Exp Optom"},{"key":"R4-20260422","doi-asserted-by":"crossref","first-page":"201","DOI":"10.3928\/1081597X-20220110-01","article-title":"Repeatability and agreement of a new Scheimpflug device and a Hartmann-Shack aberrometer with a ray-tracing aberrometer in normal, keratoconus, and CXL groups","volume":"38","author":"Kundu","year":"2022","journal-title":"J Refract Surg"},{"key":"R5-20260422","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.jcrs.2018.02.015","article-title":"Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras","volume":"44","author":"Savini","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R6-20260422","doi-asserted-by":"crossref","first-page":"19478","DOI":"10.1038\/s41598-022-24017-8","article-title":"Evaluation of three biometric devices: Ocular parameters and calculated intraocular lens power","volume":"12","author":"Lender","year":"2022","journal-title":"Sci Rep"},{"key":"R7-20260422","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1038\/s41598-020-79674-4","article-title":"Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices","volume":"11","author":"Schiano-Lomoriello","year":"2021","journal-title":"Sci Rep"},{"key":"R8-20260422","doi-asserted-by":"crossref","first-page":"2598","DOI":"10.1016\/j.jcrs.2015.06.029","article-title":"Precision (repeatability and reproducibility) studies and sample-size calculation","volume":"41","author":"McAlinden","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260422","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/j.jcrs.0000000000001023","article-title":"Repeatability of new optical biometer and agreement with 2 validated optical biometers, all based on SS-OCT","volume":"49","author":"Galzignato","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"R10-20260422","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1097\/j.jcrs.0000000000000775","article-title":"Repeatability and agreement of wavefront aberrations of a new hybrid topographer and aberrometer in healthy eyes","volume":"48","author":"Shetty","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R12-20260422","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.ophtha.2007.05.035","article-title":"Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes","volume":"115","author":"Budenz","year":"2008","journal-title":"Ophthalmology"},{"key":"R13-20260422","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"R14-20260422","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"R15-20260422","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015","article-title":"Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography","volume":"187","author":"Nakamura","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R16-20260422","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1186\/s12886-021-02213-w","article-title":"Prediction of effective Lens position using anterior segment optical coherence tomography in Chinese subjects with angle closure","volume":"21","author":"Wu","year":"2021","journal-title":"BMC Ophthalmol"},{"key":"R17-20260422","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.1007\/s00417-022-05571-3","article-title":"Five-year follow-up of corneal morphology and corneal refractive power changes after uneventful DMEK","volume":"260","author":"Lazaridis","year":"2022","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R18-20260422","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1186\/s12886-019-1236-5","article-title":"Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group","volume":"19","author":"Chen","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"R19-20260422","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.1136\/bjophthalmol-2013-303477","article-title":"Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis","volume":"97","author":"Fukuda","year":"2013","journal-title":"Br J Ophthalmol"},{"key":"R20-20260422","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1167\/iovs.12-10105","article-title":"Relationship between changes in crystalline lens shape and axial elongation in young children","volume":"54","author":"Ishii","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R21-20260422","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s00417-017-3832-5","article-title":"Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT","volume":"256","author":"Mart\u00ednez-Albert","year":"2018","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R22-20260422","doi-asserted-by":"crossref","first-page":"288","DOI":"10.4103\/ijo.IJO_729_16","article-title":"Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes","volume":"65","author":"Kumar","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R23-20260422","doi-asserted-by":"crossref","first-page":"5263","DOI":"10.1167\/iovs.14-15055","article-title":"Repeatability and agreement of three Scheimpflug-based imaging systems for measuring anterior segment parameters in keratoconus","volume":"55","author":"Shetty","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R24-20260422","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1186\/s12886-019-1144-8","article-title":"Anterior chamber depth - A predictor of refractive outcomes after age-related cataract surgery","volume":"19","author":"Ning","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"R25-20260422","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1097\/j.jcrs.0000000000000633","article-title":"Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer","volume":"47","author":"Fi\u015fu\u015f","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R26-20260422","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s10792-020-01552-9","article-title":"Agreement of white-to-white measurements with swept-source OCT, Scheimpflug and color LED devices","volume":"41","author":"Ta\u00f1\u00e1-Rivero","year":"2021","journal-title":"Int Ophthalmol"},{"key":"R27-20260422","doi-asserted-by":"crossref","first-page":"347","DOI":"10.3928\/1081597X-20230202-02","article-title":"Keratometry agreement between two swept-source OCT devices in healthy and post-refractive surgery eyes","volume":"39","author":"Mart\u00ednez-Albert","year":"2023","journal-title":"J Refract Surg"},{"key":"R28-20260422","doi-asserted-by":"crossref","first-page":"6921","DOI":"10.3390\/jcm11236921","article-title":"Measurements of anterior and posterior corneal curvatures with OCT and Scheimpflug biometers in patients with low total corneal astigmatism","volume":"11","author":"Muzyka-Wo\u017aniak","year":"2022","journal-title":"J Clin Med"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_805_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:27:50Z","timestamp":1787837270000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_805_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,26]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_805_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,26]]},"assertion":[{"value":"2024-04-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}