{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T18:36:53Z","timestamp":1791916613314,"version":"4.3.4"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:p>Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple. Several devices and technologies allow to explore and manage patients better. Optical coherence tomography (OCT) technology has evolved over the years, and hence a detailed evaluation of anterior segment (AS) structures such as cornea, conjunctiva, tear meniscus, anterior chamber, iris, and crystalline lens has been possible in a noncontact and safe procedure. The purpose of this special issue is to present and update in the evaluation of cornea and ocular surface, and this paper reviews a description of the AS-OCT, presenting the technology and common clinical uses of OCT in the management of diseases involving cornea and ocular surface to provide an updated information of the clinical recommendations of this technique in eye care practice.<\/jats:p>","DOI":"10.4103\/ijo.ijo_823_17","type":"journal-article","created":{"date-parts":[[2022,2,14]],"date-time":"2022-02-14T12:10:32Z","timestamp":1644840632000},"page":"367-372","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":28,"title":["Anterior segment optical coherence tomography for evaluation of cornea and ocular surface"],"prefix":"10.4103","volume":"66","author":[{"given":"Mittanamalli S","family":"Sridhar","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Krishna Institute of Medical Sciences, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raul","family":"Martin","sequence":"additional","affiliation":[{"name":"Departamento de F\u00edsica Te\u00f3rica, At\u00f3mica y \u00d3ptica, Universidad de Valladolid, Valladolid, Spain"},{"name":"Instituto Universitario de Oftalmobiolog\u00eda Aplicada, Universidad de Valladolid, Valladolid, Spain"},{"name":"School of Optometry, IOBA Eye Institute, University of Valladolid, Valladolid, Spain"},{"name":"Faculty of Health and Human Sciences, Plymouth University, PL6 8BH Plymouth, England"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20251013","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.jcrs.2010.05.002","article-title":"Value of optical coherence tomography for anterior segment surgery","volume":"36","author":"Doors","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R2-20251013","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1001\/archopht.1994.01090240090031","article-title":"Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography","volume":"112","author":"Izatt","year":"1994","journal-title":"Arch Ophthalmol"},{"key":"R3-20251013","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1111\/j.1442-9071.2008.01823.x","article-title":"Clinical and research applications of anterior segment optical coherence tomography \u2013 A review","volume":"37","author":"Ramos","year":"2009","journal-title":"Clin Exp Ophthalmol"},{"key":"R4-20251013","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/IIO.0000000000000164","article-title":"Anterior segment optical coherence tomography (AS-OCT) in the management of dry eye","volume":"57","author":"Gumus","year":"2017","journal-title":"Int Ophthalmol Clin"},{"key":"R5-20251013","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.jtos.2013.11.001","article-title":"Ultra high-resolution anterior segment optical coherence tomography in the diagnosis and management of ocular surface squamous neoplasia","volume":"12","author":"Thomas","year":"2014","journal-title":"Ocul Surf"},{"key":"R6-20251013","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1097\/ICO.0000000000000520","article-title":"Determination of surgical strategies for burn-induced conjunctivalized corneas using optical coherence tomography","volume":"34","author":"Wang","year":"2015","journal-title":"Cornea"},{"key":"R7-20251013","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1136\/bjophthalmol-2015-307348","article-title":"Autologous simple limbal epithelial transplantation for unilateral limbal stem cell deficiency: Multicentre results","volume":"100","author":"Vazirani","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R8-20251013","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1097\/APO.0000000000000163","article-title":"Optical coherence tomography in cultivated limbal epithelial stem cell transplantation surgery","volume":"4","author":"Zakaria","year":"2015","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R9-20251013","doi-asserted-by":"crossref","first-page":"2450","DOI":"10.1016\/j.ophtha.2012.06.050","article-title":"Anterior segment optical coherence tomography in congenital corneal opacities","volume":"119","author":"Majander","year":"2012","journal-title":"Ophthalmology"},{"key":"R10-20251013","doi-asserted-by":"crossref","first-page":"OCT69","DOI":"10.1167\/iovs.15-18825","article-title":"Pediatric optical coherence tomography in clinical practice-recent progress","volume":"57","author":"Lee","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R11-20251013","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/j.ajo.2008.08.023","article-title":"Anterior segment optical coherence tomography and ultrasound biomicroscopy in the imaging of anterior segment tumors","volume":"147","author":"Pavlin","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"R12-20251013","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1111\/j.1444-0938.2008.00318.x","article-title":"Imaging of primary cyst of the iris pigment epithelium using anterior segment OCT and ultrasonic biomicroscopy","volume":"92","author":"Pong","year":"2009","journal-title":"Clin Exp Optom"},{"key":"R13-20251013","doi-asserted-by":"crossref","first-page":"647","DOI":"10.4321\/S0365-66912006001100006","article-title":"Exploration of the anterior segment by optical coherence tomography-3","volume":"81","author":"Lara-Medina","year":"2006","journal-title":"Arch Soc Esp Oftalmol"},{"key":"R14-20251013","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.ophtha.2016.10.003","article-title":"Optical coherence tomography angiography characteristics of iris melanocytic tumors","volume":"124","author":"Skalet","year":"2017","journal-title":"Ophthalmology"},{"key":"R15-20251013","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1016\/j.jcrs.2013.10.029","article-title":"Corneal stroma demarcation line after standard and high-intensity collagen crosslinking determined with anterior segment optical coherence tomography","volume":"40","author":"Kymionis","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R16-20251013","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.1097\/ICO.0000000000000275","article-title":"OCT-derived comparison of corneal thickness distribution and asymmetry differences between normal and keratoconic eyes","volume":"33","author":"Kanellopoulos","year":"2014","journal-title":"Cornea"},{"key":"R17-20251013","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1097\/ICO.0000000000000568","article-title":"Screening for subclinical keratoconus using swept-source fourier domain anterior segment optical coherence tomography","volume":"34","author":"Steinberg","year":"2015","journal-title":"Cornea"},{"key":"R18-20251013","first-page":"1","article-title":"Intracorneal ring segment depth in keratoconus patients: A long-term follow-up study","volume":"12","author":"Shahhoseini","year":"2017","journal-title":"Int Ophthalmol"},{"key":"R19-20251013","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1159\/000337483","article-title":"Imaging of a severe case of acute hydrops in a patient with keratoconus using anterior segment optical coherence tomography","volume":"3","author":"Ueno","year":"2012","journal-title":"Case Rep Ophthalmol"},{"key":"R20-20251013","doi-asserted-by":"crossref","first-page":"352","DOI":"10.3928\/1081597X-20170216-01","article-title":"AS-OCT as a rescue tool during difficult lenticule extraction in SMILE","volume":"33","author":"Titiyal","year":"2017","journal-title":"J Refract Surg"},{"key":"R21-20251013","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.jcrs.2011.11.025","article-title":"Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by fourier-domain optical coherence tomography","volume":"38","author":"Tang","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R22-20251013","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.2147\/OPTH.S111620","article-title":"Meta-analysis and review: Effectiveness, safety, and central port design of the intraocular collamer lens","volume":"10","author":"Packer","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R23-20251013","first-page":"831","article-title":"Posterior chamber phakic intraocular lens implantation for high myopia","volume":"6","author":"Ju","year":"2013","journal-title":"Int J Ophthalmol"},{"key":"R24-20251013","first-page":"1006","article-title":"Comparison of corneal flaps created by wavelight FS200 and intralase FS60 femtosecond lasers","volume":"9","author":"Liu","year":"2016","journal-title":"Int J Ophthalmol"},{"key":"R25-20251013","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.ajo.2008.05.030","article-title":"Assessment of the use of anterior segment optical coherence tomography in microbial keratitis","volume":"146","author":"Konstantopoulos","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"R26-20251013","doi-asserted-by":"crossref","first-page":"320","DOI":"10.5301\/ejo.5000424","article-title":"Anterior segment optical coherence tomography in evaluation of severe fungal keratitis infections treated by corneal crosslinking","volume":"24","author":"Abbouda","year":"2014","journal-title":"Eur J Ophthalmol"},{"key":"R27-20251013","doi-asserted-by":"crossref","first-page":"1332","DOI":"10.1097\/ICO.0000000000000269","article-title":"In vivo imaging of coin-shaped lesions in cytomegalovirus corneal endotheliitis by anterior segment optical coherence tomography","volume":"33","author":"Yokogawa","year":"2014","journal-title":"Cornea"},{"key":"R28-20251013","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1097\/ICO.0000000000001126","article-title":"Advantages of anterior segment optical coherence tomography evaluation of the kayser-fleischer ring in wilson disease","volume":"36","author":"Sridhar","year":"2017","journal-title":"Cornea"},{"key":"R29-20251013","doi-asserted-by":"crossref","first-page":"605729","DOI":"10.1155\/2015\/605729","article-title":"Clinical applications of anterior segment optical coherence tomography","volume":"2015","author":"Lim","year":"2015","journal-title":"J Ophthalmol"},{"key":"R30-20251013","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1159\/000334946","article-title":"Anterior segment OCT-based diagnosis and management of descemet's membrane detachment","volume":"227","author":"Zhou","year":"2012","journal-title":"Ophthalmologica"},{"key":"R31-20251013","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.sjopt.2016.01.001","article-title":"Continuous intraoperative OCT guided management of post-deep anterior lamellar keratoplasty descemet's membrane detachment","volume":"30","author":"Sharma","year":"2016","journal-title":"Saudi J Ophthalmol"},{"key":"R32-20251013","doi-asserted-by":"crossref","first-page":"562062","DOI":"10.1155\/2014\/562062","article-title":"Efficacy of intraoperative anterior segment optical coherence tomography during descemet's stripping automated endothelial keratoplasty","volume":"2014","author":"Miyakoshi","year":"2014","journal-title":"ISRN Ophthalmol"},{"key":"R33-20251013","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1097\/ICO.0000000000001192","article-title":"Intraoperative optical coherence tomography-assisted descemet stripping automated endothelial keratoplasty for anterior chamber fibrous ingrowth","volume":"36","author":"Shazly","year":"2017","journal-title":"Cornea"},{"key":"R34-20251013","doi-asserted-by":"crossref","first-page":"26","DOI":"10.4103\/2008-322X.156092","article-title":"Ultra high resolution optical coherence tomography in boston type I keratoprosthesis","volume":"10","author":"Zarei-Ghanavati","year":"2015","journal-title":"J Ophthalmic Vis Res"},{"key":"R35-20251013","doi-asserted-by":"crossref","first-page":"e70673","DOI":"10.1371\/journal.pone.0070673","article-title":"Anterior segment optical coherence tomography for the quantitative evaluation of the anterior segment following boston keratoprosthesis","volume":"8","author":"Kang","year":"2013","journal-title":"PLoS One"},{"key":"R36-20251013","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1097\/ICO.0b013e318285c8f4","article-title":"High-resolution spectral domain anterior segment optical coherence tomography in type 1 boston keratoprosthesis","volume":"32","author":"Shapiro","year":"2013","journal-title":"Cornea"},{"key":"R37-20251013","first-page":"S0039","article-title":"Anterior segment optical coherence tomography for the diagnosis of corneal dystrophies according to the IC3D classification","volume":"9","author":"Siebelmann","year":"2017","journal-title":"Surv Ophthalmol"},{"key":"R38-20251013","first-page":"1","article-title":"Anterior lens capsule and iris thicknesses in pseudoexfoliation syndrome","volume":"14","author":"Batur","year":"2017","journal-title":"Curr Eye Res"},{"key":"R39-20251013","doi-asserted-by":"crossref","first-page":"5679","DOI":"10.1167\/iovs.11-7274","article-title":"Anterior segment optical coherence tomography analysis of clinically unilateral pseudoexfoliation syndrome: Evidence of bilateral involvement and morphologic factors related to asymmetry","volume":"52","author":"Zheng","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R40-20251013","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.jcrs.2017.01.026","article-title":"Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography","volume":"43","author":"Hirnschall","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R41-20251013","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.1016\/j.jcrs.2014.01.036","article-title":"Fourier-domain optical coherence tomography evaluation of clear corneal incision structure according to blade material","volume":"40","author":"Lee","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R42-20251013","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.jcrs.2008.11.047","article-title":"Corneal incision quality: Microincision cataract surgery versus microcoaxial phacoemulsification","volume":"35","author":"Elkady","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R43-20251013","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1016\/j.ophtha.2012.10.015","article-title":"Visualization of blebs using anterior-segment optical coherence tomography after glaucoma drainage implant surgery","volume":"120","author":"Jung","year":"2013","journal-title":"Ophthalmology"},{"key":"R44-20251013","doi-asserted-by":"crossref","first-page":"3043","DOI":"10.1167\/iovs.06-1372","article-title":"Measurement of corneal swelling variations without removal of the contact lens during extended wear","volume":"48","author":"Martin","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R45-20251013","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.clae.2017.04.006","article-title":"Scleral topography analysed by optical coherence tomography","volume":"40","author":"Bandlitz","year":"2017","journal-title":"Cont Lens Anterior Eye"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/02223307-201866030-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:30:04Z","timestamp":1787758204000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02223307-201866030-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":45,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_823_17","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3]]},"assertion":[{"value":"2017-09-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-10-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}