{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:50:29Z","timestamp":1791359429317,"version":"4.3.1"},"reference-count":68,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:p>Glaucoma is a leading cause of irreversible blindness worldwide, with global prevalence projected to rise substantially in the coming decades. Advances in digital health technology have enabled the development of home-based monitoring devices that support patient-centered care. This review provides a comprehensive overview of current and emerging technologies for home glaucoma monitoring, focusing on intraocular pressure (IOP) assessment, optic disc imaging, and visual field testing. Home tonometry includes rebound devices such as the iCare HOME rebound tonometer and Tap Eye tonometer. Continuous IOP monitoring approaches include contact lens sensors (CLSs) such as Triggerfish CLS, miLens microfludic CLS, and implantable telemetric systems including Eyemate-IO and Eyemate-SC, offering insights into diurnal IOP fluctuations. IOP Connect (Injectsense) is a miniature implant that records and wirelessly uploads IOP data, though long-term validation is pending. Q Smart (Qura) is a remotely powered suprachoroidal sensor with frequent measurements, currently supported only by animal data. Smartphone-based optic disc imaging and devices with smartphone adapters provide accessible structural assessment, though image quality and user dependence remain limitations. Home-based perimetry platforms such as Melbourne rapid fields, Peristat, Eyeonic online circular-contrast perimetry, VisuALL, C3 Field Analyzer, Mobile virtual perimetry\u2013Frequency\u2013doubling technology, and Eyecatcher 3.0 show good agreement with standard automated perimetry while enhancing accessibility and testing frequency. Although these technologies show considerable potential to enhance disease surveillance and patient engagement, barriers including cost, regulatory approval, long-term validation, and integration into clinical work flows persist. Large-scale studies and unified digital platforms integrating structural and functional data are required to establish their role in routine glaucoma care.<\/jats:p>","DOI":"10.4103\/ijo.ijo_84_26","type":"journal-article","created":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T14:03:56Z","timestamp":1790690636000},"page":"1435-1443","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Home monitoring devices for glaucoma"],"prefix":"10.4103","volume":"74","author":[{"given":"Tarannum","family":"Mansoori","sequence":"first","affiliation":[{"name":"Department of Glaucoma, Prime Retina Eye Care Centre, Himayatnagar, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amrita Kapoor","family":"Chaturvedi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Amrita School of Medicine, Amrita Vishwa Vidyapeetham, Faridabad, Haryana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George YX","family":"Kong","sequence":"additional","affiliation":[{"name":"Department of Glaucoma, Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnav","family":"Panigrahi","sequence":"additional","affiliation":[{"name":"Department of Glaucoma, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manzoor A","family":"Malik","sequence":"additional","affiliation":[{"name":"Department of Glaucoma, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaweh","family":"Mansouri","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Colorado School of Medicine, Colorado, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viney","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Amrita School of Medicine, Amrita Vishwa Vidyapeetham, Faridabad, Haryana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,29]]},"reference":[{"key":"R1-20261007","doi-asserted-by":"crossref","first-page":"2081","DOI":"10.1016\/j.ophtha.2014.05.013","article-title":"Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta-analysis","volume":"121","author":"Tham","year":"2014","journal-title":"Ophthalmology"},{"key":"R2-20261007","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1080\/08820538.2021.1896759","article-title":"Home monitoring for glaucoma: Current applications and future directions","volume":"36","author":"Aboobakar","year":"2021","journal-title":"Semin Ophthalmol"},{"key":"R3-20261007","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1038\/s41433-019-0669-7","article-title":"Home monitoring for glaucoma","volume":"34","author":"Che","year":"2020","journal-title":"Eye (Lond)"},{"key":"R4-20261007","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.ogla.2022.05.001","article-title":"Home monitoring of glaucoma using a home tonometer and a novel virtual reality visual field device: Acceptability and feasibility","volume":"6","author":"Hu","year":"2023","journal-title":"Ophthalmol Glaucoma"},{"key":"R5-20261007","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1136\/bjophthalmol-2015-307674","article-title":"Evaluation of a new rebound tonometer for self-measurement of intraocular pressure","volume":"100","author":"Dabasia","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R6-20261007","doi-asserted-by":"crossref","first-page":"4031","DOI":"10.2147\/OPTH.S284844","article-title":"Icare home tonometer: A review of characteristics and clinical utility","volume":"14","author":"Liu","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"R7-20261007","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1016\/j.ophtha.2016.04.044","article-title":"The Icare HOME (TA022) study: Performance of an intraocular pressure measuring device for self-tonometry by glaucoma patients","volume":"123","author":"Mudie","year":"2016","journal-title":"Ophthalmology"},{"key":"R8-20261007","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1177\/11206721221099252","article-title":"iCare(R) Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre","volume":"33","author":"Querat","year":"2023","journal-title":"Eur J Ophthalmol"},{"key":"R9-20261007","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1111\/aos.12108","article-title":"Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure","volume":"92","author":"Sakamoto","year":"2014","journal-title":"Acta Ophthalmol"},{"key":"R10-20261007","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1097\/IJG.0000000000000424","article-title":"Self-monitoring of intraocular pressure outside of normal office hours using rebound tonometry: Initial clinical experience in patients with normal tension glaucoma","volume":"25","author":"Sood","year":"2016","journal-title":"J Glaucoma"},{"key":"R11-20261007","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1097\/IJG.0000000000000674","article-title":"Evaluation of a new rebound self-tonometer, Icare HOME: Comparison with Goldmann applanation tonometer","volume":"26","author":"Takagi","year":"2017","journal-title":"J Glaucoma"},{"key":"R12-20261007","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/IJG.0000000000000390","article-title":"Accuracy of measurements with the iCare HOME rebound tonometer","volume":"25","author":"Termuhlen","year":"2016","journal-title":"J Glaucoma"},{"key":"R13-20261007","doi-asserted-by":"crossref","first-page":"e0302568","DOI":"10.1371\/journal.pone.0302568","article-title":"Evaluation of a new transpalpebral tonometer for self-measuring intraocular pressure","volume":"19","author":"Kobashi","year":"2024","journal-title":"PLoS One"},{"key":"R14-20261007","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1001\/jamaophthalmol.2018.1746","article-title":"Association between 24-hour intraocular pressure monitored with contact lens sensor and visual field progression in older adults with glaucoma","volume":"136","author":"De Moraes","year":"2018","journal-title":"JAMA Ophthalmol"},{"key":"R15-20261007","doi-asserted-by":"crossref","first-page":"875","DOI":"10.2147\/OPTH.S109708","article-title":"The Sensimed Triggerfish contact lens sensor: Efficacy, safety, and patient perspectives","volume":"11","author":"Dunbar","year":"2017","journal-title":"Clin Ophthalmol"},{"key":"R16-20261007","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1097\/IJG.0b013e31829e5635","article-title":"Evaluation of continuous 24-hour intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma","volume":"23","author":"Hollo","year":"2014","journal-title":"J Glaucoma"},{"key":"R17-20261007","first-page":"260","article-title":"The road ahead to continuous 24-hour intraocular pressure monitoring in glaucoma","volume":"9","author":"Mansouri","year":"2014","journal-title":"J Ophthalmic Vis Res"},{"key":"R18-20261007","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1001\/archophthalmol.2012.2280","article-title":"Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma","volume":"130","author":"Mansouri","year":"2012","journal-title":"Arch Ophthalmol"},{"key":"R19-20261007","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1136\/bjo.2010.192922","article-title":"Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma","volume":"95","author":"Mansouri","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"R20-20261007","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1001\/jamaophthalmol.2013.5297","article-title":"24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor","volume":"131","author":"Mottet","year":"2013","journal-title":"JAMA Ophthalmol"},{"key":"R21-20261007","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.ajo.2019.09.011","article-title":"Telemetric Measurement of Intraocular Pressure via an Implantable Pressure Sensor-12-Month Results from the ARGOS-02 Trial","volume":"209","author":"Choritz","year":"2020","journal-title":"Am J Ophthalmol"},{"key":"R22-20261007","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1167\/iovs.14-14925","article-title":"Implantation of a novel telemetric intraocular pressure sensor in patients with glaucoma (ARGOS study): 1-year results","volume":"56","author":"Koutsonas","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R23-20261007","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1111\/ceo.13100","article-title":"Long-term follow-up after implantation of a telemetric intraocular pressure sensor in patients with glaucoma: A safety report","volume":"46","author":"Koutsonas","year":"2018","journal-title":"Clin Exp Ophthalmol"},{"key":"R24-20261007","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1136\/bjophthalmol-2021-319786","article-title":"Telemetric non-contact intraocular pressure monitoring with an implanted sensor in patients with glaucoma: Long-term safety report and monitoring data","volume":"107","author":"Schmidt","year":"2023","journal-title":"Br J Ophthalmol"},{"key":"R25-20261007","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.exer.2016.07.016","article-title":"Investigation of a novel implantable suprachoroidal pressure transducer for telemetric intraocular pressure monitoring","volume":"151","author":"Mariacher","year":"2016","journal-title":"Exp Eye Res"},{"key":"R26-20261007","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.ophtha.2022.09.021","article-title":"EYEMATE-SC Trial: Twelve-month safety, performance, and accuracy of a suprachoroidal sensor for telemetric measurement of intraocular pressure","volume":"130","author":"Szurman","year":"2023","journal-title":"Ophthalmology"},{"key":"R27-20261007","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1136\/bjophthalmol-2021-320023","article-title":"Safety and performance of a suprachoroidal sensor for telemetric measurement of intraocular pressure in the EYEMATE-SC trial","volume":"107","author":"Szurman","year":"2023","journal-title":"Br J Ophthalmol"},{"key":"R28-20261007","first-page":"35","article-title":"IOP monitoring via a smartphone","volume":"23","author":"Zhang","year":"2025","journal-title":"Glaucoma Today"},{"key":"R29-20261007","article-title":"Injectsense completes first human implantation of its ultraminiaturized intraocular pressure sensor","journal-title":"PR Newswire"},{"key":"R30-20261007","article-title":"Implantable pressure sensor that could improve glaucoma treatment advances through Purdue agreement","year":"2018"},{"key":"R31-20261007","doi-asserted-by":"crossref","first-page":"e109","DOI":"10.1097\/IJG.0000000000001251","article-title":"Smartphone disc photography versus standard stereoscopic disc photography as a teaching tool","volume":"28","author":"Pujari","year":"2019","journal-title":"J Glaucoma"},{"key":"R32-20261007","doi-asserted-by":"crossref","first-page":"10228","DOI":"10.1038\/s41598-018-28585-6","article-title":"Undilated versus dilated monoscopic smartphone-based fundus photography for optic nerve head evaluation","volume":"8","author":"Wintergerst","year":"2018","journal-title":"Sci Rep"},{"key":"R33-20261007","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/j.survophthal.2020.04.004","article-title":"Functional assessment of glaucoma: Uncovering progression","volume":"65","author":"Hu","year":"2020","journal-title":"Surv Ophthalmol"},{"key":"R34-20261007","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1136\/bjo.2007.135012","article-title":"Practical recommendations for measuring rates of visual field change in glaucoma","volume":"92","author":"Chauhan","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"R35-20261007","doi-asserted-by":"crossref","first-page":"2770","DOI":"10.1167\/iovs.12-9476","article-title":"Intervals between visual field tests when monitoring the glaucomatous patient: Wait-and-see approach","volume":"53","author":"Crabb","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R36-20261007","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1016\/j.ophtha.2017.06.028","article-title":"Can home monitoring allow earlier detection of rapid visual field progression in glaucoma?","volume":"124","author":"Anderson","year":"2017","journal-title":"Ophthalmology"},{"key":"R37-20261007","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1136\/bjophthalmol-2012-302903","article-title":"Are practical recommendations practiced? A national multi-centre cross-sectional study on frequency of visual field testing in glaucoma","volume":"97","author":"Fung","year":"2013","journal-title":"Br J Ophthalmol"},{"key":"R38-20261007","doi-asserted-by":"crossref","first-page":"102","DOI":"10.17925\/EOR.2018.12.2.102","article-title":"Home monitoring in glaucoma","volume":"12","author":"Boote","year":"2018","journal-title":"Eur Ophthal Rev"},{"key":"R39-20261007","doi-asserted-by":"crossref","first-page":"1485950","DOI":"10.3389\/fopht.2025.1485950","article-title":"Multi-centre comparison between device-independent web-browser perimetry (Melbourne Rapid Fields-web) and SITA-Faster for glaucoma","volume":"5","author":"Tiang","year":"2025","journal-title":"Front Ophthalmol (Lausanne)"},{"key":"R40-20261007","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1111\/ceo.13082","article-title":"Performance of iPad-based threshold perimetry in glaucoma and controls","volume":"46","author":"Schulz","year":"2018","journal-title":"Clin Exp Ophthalmol"},{"key":"R41-20261007","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1167\/tvst.5.4.3","article-title":"Validation of a tablet as a tangent perimeter","volume":"5","author":"Vingrys","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"R42-20261007","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1167\/tvst.13.5.10","article-title":"Measuring visual fields in children with glaucoma using a portable tablet","volume":"13","author":"Gupta","year":"2024","journal-title":"Transl Vis Sci Technol"},{"key":"R43-20261007","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1167\/tvst.5.6.2","article-title":"A comparison of perimetric results from a tablet perimeter and humphrey field analyzer in glaucoma patients","volume":"5","author":"Kong","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"R44-20261007","first-page":"8384509","article-title":"Comparison of perimetric outcomes from melbourne rapid fields tablet perimeter software and Humphrey Field analyzer in glaucoma patients","volume":"2020","author":"Kumar","year":"2020","journal-title":"J Ophthalmol"},{"key":"R45-20261007","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.ajo.2020.10.023","article-title":"Uptake, persistence, and performance of weekly home monitoring of visual field in a large cohort of patients with glaucoma","volume":"223","author":"Prea","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"R46-20261007","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.ajo.2018.03.009","article-title":"Six-month longitudinal comparison of a portable tablet perimeter with the Humphrey Field analyzer","volume":"190","author":"Prea","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R47-20261007","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/02713680490522399","article-title":"Peristat: A computer-based perimetry self-test for cost-effective population screening of glaucoma","volume":"30","author":"Ianchulev","year":"2005","journal-title":"Curr Eye Res"},{"key":"R48-20261007","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1167\/tvst.5.4.4","article-title":"Comparison of peristat online perimetry with the humphrey perimetry in a clinic-based setting","volume":"5","author":"Lowry","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"R49-20261007","doi-asserted-by":"crossref","first-page":"201","DOI":"10.2147\/OPTH.S440964","article-title":"Online circular contrast perimetry via a web-application: Establishing a normative database for central 10-degree perimetry","volume":"18","author":"Chen","year":"2024","journal-title":"Clin Ophthalmol"},{"key":"R50-20261007","doi-asserted-by":"crossref","first-page":"15","DOI":"10.5005\/jp-journals-10078-1468","article-title":"Evaluating the consistency of online circular contrast perimetry across different computer monitors: A cross-sectional study","volume":"19","author":"Gong","year":"2025","journal-title":"J Curr Glaucoma Pract"},{"key":"R51-20261007","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.2147\/OPTH.S519093","article-title":"Glaucoma home monitoring using online circular contrast perimetry over 6 months: Performance and patient attitudes in the developing world setting","volume":"19","author":"Hoang","year":"2025","journal-title":"Clin Ophthalmol"},{"key":"R52-20261007","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1097\/IJG.0000000000002384","article-title":"Repeatability of online circular contrast perimetry compared to standard automated perimetry","volume":"33","author":"Meyerov","year":"2024","journal-title":"J Glaucoma"},{"key":"R53-20261007","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1097\/APO.0000000000000589","article-title":"Online circular contrast perimetry: A comparison to standard automated perimetry","volume":"12","author":"Meyerov","year":"2023","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R54-20261007","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1038\/s41433-022-02085-4","article-title":"Online circular contrast perimetry via a web-application: Optimising parameters and establishing a normative database","volume":"37","author":"Skalicky","year":"2023","journal-title":"Eye (Lond)"},{"key":"R55-20261007","doi-asserted-by":"crossref","first-page":"4","DOI":"10.5005\/jp-journals-10078-1434","article-title":"Prospective comparison of VisuALL virtual reality perimetry and humphrey automated perimetry in glaucoma","volume":"18","author":"Griffin","year":"2024","journal-title":"J Curr Glaucoma Pract"},{"key":"R56-20261007","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1167\/tvst.12.1.6","article-title":"Evaluation of virtual reality perimetry and standard automated perimetry in normal children","volume":"12","author":"Groth","year":"2023","journal-title":"Transl Vis Sci Technol"},{"key":"R57-20261007","doi-asserted-by":"crossref","first-page":"e0318074","DOI":"10.1371\/journal.pone.0318074","article-title":"Virtual reality perimetry compared to standard automated perimetry in adults with glaucoma: A systematic review","volume":"20","author":"Hekmatjah","year":"2025","journal-title":"PLoS One"},{"key":"R58-20261007","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1167\/tvst.10.3.20","article-title":"A Virtual reality-based automated perimeter, device, and pilot study","volume":"10","author":"Montelongo","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"R59-20261007","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/IJG.0000000000001670","article-title":"Preliminary report on a novel virtual reality perimeter compared with standard automated perimetry","volume":"30","author":"Razeghinejad","year":"2021","journal-title":"J Glaucoma"},{"key":"R60-20261007","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1167\/tvst.13.8.7","article-title":"Glaucoma home self-testing using VR visual fields and rebound tonometry versus in-clinic perimetry and Goldmann applanation tonometry: A pilot study","volume":"13","author":"Berneshawi","year":"2024","journal-title":"Transl Vis Sci Technol"},{"key":"R61-20261007","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/IJG.0000000000001415","article-title":"Validation of a head-mounted virtual reality visual field screening device","volume":"29","author":"Mees","year":"2020","journal-title":"J Glaucoma"},{"key":"R62-20261007","first-page":"413","article-title":"Screening for glaucomatous visual field loss with frequency-doubling perimetry","volume":"38","author":"Johnson","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R63-20261007","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1136\/bjophthalmol-2019-314031","article-title":"Low-cost, smartphone-based frequency doubling technology visual field testing using a head-mounted display","volume":"105","author":"Alawa","year":"2021","journal-title":"Br J Ophthalmol"},{"key":"R64-20261007","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1167\/tvst.9.8.18","article-title":"An open-source static threshold perimetry test using remote eye-tracking (eyecatcher): Description, validation, and preliminary normative data","volume":"9","author":"Jones","year":"2020","journal-title":"Transl Vis Sci Technol"},{"key":"R65-20261007","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1167\/tvst.8.1.17","article-title":"Portable perimetry using eye-tracking on a tablet computer-A feasibility assessment","volume":"8","author":"Jones","year":"2019","journal-title":"Transl Vis Sci Technol"},{"key":"R66-20261007","doi-asserted-by":"crossref","first-page":"e043130","DOI":"10.1136\/bmjopen-2020-043130","article-title":"Acceptability of a home-based visual field test (Eyecatcher) for glaucoma home monitoring: A qualitative study of patients\u2019 views and experiences","volume":"11","author":"Jones","year":"2021","journal-title":"BMJ Open"},{"key":"R67-20261007","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.ajo.2020.08.039","article-title":"Glaucoma home monitoring using a tablet-based visual field test (Eyecatcher): An assessment of accuracy and adherence over 6 months","volume":"223","author":"Jones","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"R68-20261007","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1167\/tvst.14.8.7","article-title":"Eyecatcher 3.0 - validating the use of \u201csmart glasses\u201d as a low-cost, portable method of assessing visual fields","volume":"14","author":"Rathore","year":"2025","journal-title":"Transl Vis Sci Technol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_84_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:00:34Z","timestamp":1791356434000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_84_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,29]]},"references-count":68,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_84_26","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,29]]},"assertion":[{"value":"2026-01-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}