{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:21:38Z","timestamp":1787757698044,"version":"build-2784847793"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>The Castroviejo caliper is routinely used for measuring the corneal diameter in patients with primary congenital glaucoma, but needs an examination under anesthesia (EUA) or sedation. A simple U-shaped tool was devised to aid in the estimation of the corneal diameters of patients in settings where an ophthalmic caliper is not available or EUA is not feasible.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Infants presenting to the congenital glaucoma clinic posted for EUA were recruited. The demographic details of the patients such as age, sex, and diagnosis were noted. A simple U-shaped tool was devised using three Schirmer strips or a printable ruler. Before the patient underwent a EUA, the corneal diameters were measured using the U-tool. During EUA, corneal diameters were measured using the Castroviejo caliper.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean age of infants was 6.7 \u00b1 3.39 months (R = 1\u201312). The mean corneal diameter measured using the U-tool was 13.29 \u00b1 1.33 mm and with Castroviejo caliper was 13.18 \u00b1 1.39 mm. The difference between the corneal diameters measured using the two techniques was \u22120.114 mm with the Bland\u2013Altman plot 95% Limits of agreement (LoA) from \u22120.965 to 0.737 mm. Corneal diameters measured with both instruments had a good correlation (Pearson\u2019s correlation coefficient = 0.95,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>U-tool can be used for screening congenital glaucoma by first-contact physicians or optometrists. It can also be used by ophthalmologists when EUA is delayed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_930_21","type":"journal-article","created":{"date-parts":[[2021,12,27]],"date-time":"2021-12-27T06:00:43Z","timestamp":1640584843000},"page":"143-146","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Validating the use of U-tool as a novel method for measuring the corneal diameter in infants screened for congenital glaucoma"],"prefix":"10.4103","volume":"70","author":[{"given":"Rahul Kumar","family":"Bafna","sequence":"first","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karthikeyan","family":"Mahalingam","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vaishali","family":"Rakheja","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Namrata","family":"Sharma","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shikha","family":"Gupta","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roy Arokiam","family":"Daniel","sequence":"additional","affiliation":[{"name":"Centre for Community Medicine, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viney","family":"Gupta","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,12,23]]},"reference":[{"key":"B1-20240828","doi-asserted-by":"crossref","first-page":"495","DOI":"10.4103\/0301-4738.43368","article-title":"Causes of childhood blindness in the northeastern states of India","volume":"56","author":"Bhattacharjee","year":"2008","journal-title":"Indian J Ophthalmol"},{"key":"B2-20240828","first-page":"76","article-title":"Epidemiology and genetics of primary congenital glaucoma in Slovakia. Description of a form of primary congenital glaucoma in gypsies with autosomal-recessive inheritance and complete penetrance","volume":"16","author":"Gen\u0109\u00edk","year":"1989","journal-title":"Dev Ophthalmol"},{"key":"B3-20240828","doi-asserted-by":"crossref","first-page":"4100","DOI":"10.1167\/iovs.06-1350","article-title":"The British infantile and childhood glaucoma (BIG) eye study","volume":"48","author":"Papadopoulos","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"B4-20240828","doi-asserted-by":"crossref","first-page":"358","DOI":"10.4103\/ijo.IJO_786_18","article-title":"Profile of childhood glaucoma at a tertiary center in South India","volume":"67","author":"Senthil","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"B5-20240828","first-page":"93","article-title":"Corneal diameter and axial length in congenital glaucoma","volume":"20","author":"Kiskis","year":"1985","journal-title":"Can J Ophthalmol J Can Ophtalmol"},{"key":"B6-20240828","first-page":"545","article-title":"Population-based assessment of childhood blindness in southern India","volume":"116","author":"Dandona","year":"1998","journal-title":"Arch Ophthalmol Chic Ill 1960"},{"key":"B7-20240828","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1136\/bjo.73.7.570","article-title":"Validation of a photographic method of measuring corneal diameter","volume":"73","author":"Robinson","year":"1989","journal-title":"Br J Ophthalmol"},{"key":"B8-20240828","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1111\/j.1444-0938.2009.00407.x","article-title":"Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems","volume":"92","author":"Salouti","year":"2009","journal-title":"Clin Exp Optom"},{"key":"B9-20240828","first-page":"1057","article-title":"Device interchangeability on anterior chamber depth and white-to-white measurements:A thorough literature review","volume":"9","author":"Dom\u00ednguez-Vicent","year":"2016","journal-title":"Int J Ophthalmol"},{"key":"B10-20240828","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1097\/ICO.0b013e3182a40786","article-title":"Comparison of horizontal corneal diameter measurements using the orbscan IIz and pentacam HR systems","volume":"32","author":"Salouti","year":"2013","journal-title":"Cornea"},{"key":"B11-20240828","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.jcjo.2013.07.007","article-title":"The precision of ophthalmic biometry using calipers","volume":"48","author":"Mohamed","year":"2013","journal-title":"Can J Ophthalmol J Can Ophtalmol"},{"key":"B12-20240828","doi-asserted-by":"crossref","first-page":"2199","DOI":"10.4103\/ijo.IJO_1560_20","article-title":"Use of 'U-shaped tool for follow up of corneal ulcer cases in the COVID-19 pandemic","volume":"68","author":"Bafna","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"B13-20240828","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet Lond Engl"},{"key":"B14-20240828","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","article-title":"Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology","volume":"31","author":"McAlinden","year":"2011","journal-title":"Ophthalmic Physiol Opt J Br Coll Ophthalmic Opt Optom"},{"key":"B15-20240828","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.ajo.2007.03.021","article-title":"A method for noncontact measurement of corneal diameter in children","volume":"144","author":"Lagr\u00e8ze","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"B16-20240828","first-page":"1069","article-title":"[Photographic estimation of corneal diameter]","volume":"22","author":"Aizawa","year":"1971","journal-title":"Nihon Ganka Kiyo"},{"key":"B17-20240828","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1136\/bjo.2004.047761","article-title":"Correlation between surgical success rate and severity of congenital glaucoma","volume":"89","author":"Al-Hazmi","year":"2005","journal-title":"Br J Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_930_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:50:47Z","timestamp":1787755847000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_930_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,23]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_930_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,23]]},"assertion":[{"value":"2021-04-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}