{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:42:49Z","timestamp":1786736569344,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indian J Ophthalmol"],"published-print":{"date-parts":[[2020]]},"DOI":"10.4103\/ijo.ijo_936_19","type":"journal-article","created":{"date-parts":[[2020,5,26]],"date-time":"2020-05-26T03:13:07Z","timestamp":1590462787000},"page":"1057","source":"Crossref","is-referenced-by-count":5,"title":["A new technique for fitting of tricurve rigid gas-permeable contact lens in penetrating keratoplasty eyes using Scheimpflug imaging"],"prefix":"10.4103","volume":"68","author":[{"given":"Pratik","family":"Gogri","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FaizaA","family":"Bhombal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"key-10.4103\/0301-4738.284852-1","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1016\/S0140-6736(12)60437-1","article-title":"Corneal transplantation","author":"Tan,","year":"2012","journal-title":"Lancet"},{"key":"key-10.4103\/0301-4738.284852-2","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1016\/0039-6257(90)90123-D","article-title":"Zadnik K.Refracting the corneal graft","author":"Mannis","year":"1990","journal-title":"Surv Ophthalmol"},{"key":"key-10.4103\/0301-4738.284852-3","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1111\/cxo.12047","article-title":"Recent advances in corneal transplantation for keratoconus","author":"Cassidy","year":"2013","journal-title":"Clin Exp Optom"},{"key":"key-10.4103\/0301-4738.284852-4","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1136\/bjo.60.4.263","article-title":"Fitting contact lenses after keratoplasty","author":"Daniel","year":"1976","journal-title":"Br J Ophthalmol"},{"key":"key-10.4103\/0301-4738.284852-5","first-page":"90","article-title":"Visual correction following penetrating keratoplasty","author":"Smiddy","year":"1992","journal-title":"Ophthalmic Surg"},{"key":"key-10.4103\/0301-4738.284852-6","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/01.ICL.0000101488.84455.E6","article-title":"Fitting contact lenses for visual rehabilitation after penetrating keratoplasty","author":"Wietharn","year":"2004","journal-title":"Eye Contact Lens"},{"key":"key-10.4103\/0301-4738.284852-7","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1097\/00006324-197503000-00005","article-title":"Visual acuity improvement in eyes with corneal scars fitted with contact lenses","author":"Dada","year":"1975","journal-title":"Am J Optom Physiol Opt"},{"key":"key-10.4103\/0301-4738.284852-8","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/ICL.0b013e3181e52dd1","article-title":"O'Donnell C.Visual acuity and ocular aberrations with different rigid gas permeable lens fittings in keratoconus","author":"Jinabhai","year":"2010","journal-title":"Eye Contact Lens"},{"key":"key-10.4103\/0301-4738.284852-9","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/S0892-8967(01)00041-4","article-title":"Complexity of contact lens fitting following penetrating keratoplasty","author":"Ho","year":"1999","journal-title":"Int Contact Lens Clin"},{"key":"key-10.4103\/0301-4738.284852-10","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1097\/01.ICL.0000072828.14773.3F","article-title":"Nomogram for spherical RGP contact lens fitting in patients with pellucid marginal corneal degeneration (PMCD)","author":"Raizada","year":"2003","journal-title":"Eye Contact Lens"},{"key":"key-10.4103\/0301-4738.284852-11","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.clae.2013.01.006","article-title":"Comparison of conventional method of contact lens fitting and software based contact lens fitting with Medmont corneal topographer in eyes with corneal scar","author":"Siddireddy","year":"2013","journal-title":"Cont Lens Anterior Eye"},{"key":"key-10.4103\/0301-4738.284852-12","unstructured":"Donshik PC, Reisner DS, Luistro AE. The use of computerized videokeratography as an aid in fitting rigid gas permeable contact lenses. Trans Am Ophthalmol Soc 1996;94:135-43. discussion 143-5."},{"key":"key-10.4103\/0301-4738.284852-13","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1034\/j.1600-0420.2001.790307.x","article-title":"A new technique for rigid gas permeable contact lens fitting following penetrating keratoplasty","author":"Eggink","year":"2001","journal-title":"Acta Ophthalmol Scand"},{"key":"key-10.4103\/0301-4738.284852-14","first-page":"22","article-title":"Comparison of axial and instantaneous videokeratographic data in keratoconus and utility in contact lens curvature prediction","author":"Szczotka","year":"1998","journal-title":"Clao J"},{"key":"key-10.4103\/0301-4738.284852-15","doi-asserted-by":"crossref","first-page":"121","DOI":"10.4103\/0301-4738.30706","article-title":"Rose-K contact lens for keratoconus","author":"Jain","year":"2007","journal-title":"Indian J Ophthalmol","ISSN":"https:\/\/id.crossref.org\/issn\/0301-4738","issn-type":"print"},{"key":"key-10.4103\/0301-4738.284852-16","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1016\/j.jcrs.2012.09.002","article-title":"Management of post-keratoplasty astigmatism","author":"Fares","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"key-10.4103\/0301-4738.284852-17","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/S0161-6420(82)34751-X","article-title":"Controlled reduction of postkeratoplasty astigmatism","author":"Stainer","year":"1982","journal-title":"Ophthalmology"},{"key":"key-10.4103\/0301-4738.284852-18","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1111\/j.1444-0938.2003.tb03113.x","article-title":"Contact lens fitting following corneal graft surgery","author":"Szczotka","year":"2003","journal-title":"Clin Exp Optom"},{"key":"key-10.4103\/0301-4738.284852-19","first-page":"14","article-title":"Management of irregular astigmatism with rigid gas permeable contact lenses","author":"Jupiter","year":"2000","journal-title":"CLAO J"},{"key":"key-10.4103\/0301-4738.284852-20","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/S0002-9394(14)77947-4","article-title":"Fitting gas-permeable contact lenses after penetrating keratoplasty","author":"Genvert","year":"1985","journal-title":"Am J Ophthalmol"},{"key":"key-10.4103\/0301-4738.284852-21","doi-asserted-by":"crossref","first-page":"e0150118","DOI":"10.1371\/journal.pone.0150118","article-title":"Corneal transplantation in disease affecting only one eye: Does it make a difference to habitual binocular viewing?","author":"Bandela","year":"2016","journal-title":"PLoS One"},{"key":"key-10.4103\/0301-4738.284852-22","first-page":"265","article-title":"Effects of long-term rigid contact lens wear on the endothelium of corneal transplants for keratoconus 10 years after penetrating keratoplasty","author":"Bourne","year":"1995","journal-title":"Clao J"},{"key":"key-10.4103\/0301-4738.284852-23","unstructured":"Van der Worp E. A guide to scleral lens fitting. 2010."},{"key":"key-10.4103\/0301-4738.284852-24","first-page":"20","article-title":"Modern scleral contact lens fitting","author":"Denaeyer","year":"2010","journal-title":"Contact Lens Spectrum"},{"key":"key-10.4103\/0301-4738.284852-25","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.clae.2013.11.001","article-title":"Scleral contact lenses for visual rehabilitation after penetrating keratoplasty: Long term outcomes","author":"Severinsky","year":"2014","journal-title":"Cont Lens Anterior Eye"},{"key":"key-10.4103\/0301-4738.284852-26","first-page":"129","article-title":"Rigid gas permeable contact lenses","author":"Lembach","year":"1990","journal-title":"Eye Contact Lens"},{"key":"key-10.4103\/0301-4738.284852-27","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/01.icl.0000191953.84449.d6","article-title":"Incidence of rigid gas-permeable contact lens wear after keratoplasty for keratoconus","author":"Geerards","year":"2006","journal-title":"Eye Contact Lens"},{"key":"key-10.4103\/0301-4738.284852-28","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1111\/j.1444-0938.1995.tb00829.x","article-title":"Post-keratoplasty contact lens management","author":"Lindsay","year":"1995","journal-title":"Clin Exp Optom"},{"key":"key-10.4103\/0301-4738.284852-29","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1136\/bjo.70.1.55","article-title":"Photokeratoscopy in fitting contact lens after penetrating keratoplasty","author":"Manabe","year":"1986","journal-title":"Br J Ophthalmol"},{"key":"key-10.4103\/0301-4738.284852-30","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1016\/S0161-6420(02)01121-1","article-title":"Role of orbscan II in screening keratoconus suspects before refractive corneal surgery","author":"Rao","year":"2002","journal-title":"Ophthalmology"},{"key":"key-10.4103\/0301-4738.284852-31","first-page":"45","article-title":"Corneal topography and tomography","author":"Dharwadkar","year":"2015","journal-title":"J Clin Ophthalmol Res","ISSN":"https:\/\/id.crossref.org\/issn\/2320-3897","issn-type":"print"},{"key":"key-10.4103\/0301-4738.284852-32","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.jcrs.2007.12.036","article-title":"Comparison of and correlation between anterior and posterior corneal elevation maps in normal eyes and keratoconus-suspect eyes","author":"Schlegel","year":"2008","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T18:43:29Z","timestamp":1786733009000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_936_19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020]]}},"alternative-id":["284852"],"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_936_19","relation":{},"ISSN":["0301-4738"],"issn-type":[{"value":"0301-4738","type":"print"}],"subject":[],"published":{"date-parts":[[2020]]}}}