{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:20:57Z","timestamp":1787761257558,"version":"build-2784847793"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the accuracy of isolated manual marking and smartphone-assisted manual marking with the Verion image-guided system for toric intraocular lens (IOL) implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective observational study, 42 eyes of 36 patients planned for phacoemulsification with toric IOL implantation with corneal astigmatism &gt;1D as measured on Lenstar LS 900 optical biometer were included. Patients were preoperatively registered and photographed on the Verion image-guided system. In the operating room, the patient's eye was manually marked at the 6 o\u2032 clock limbus (Manual axis-90\u00b0) on slit-lamp in sitting position. Next, using the smartphone android app\u2014iToric Patwardhan, the exact mark axis was confirmed (Smartphone axis). Following this, the patient was taken on the operation table where the mark axis was confirmed with Verion digital overlay on an external screen (Verion axis). The absolute angular deviation of manual axis from Verion was compared with the absolute angular deviation of the smartphone axis from Verion as the primary outcome measure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean absolute angular deviation between the smartphone axis and the Verion axis was 2.62\u00b0, which was significantly lower (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05) than that between the manual axis and Verion axis (4.60\u00b0). Moreover, the intraclass correlation coefficient between the smartphone axis and Verion axis was 0.88 indicating a strong agreement between the two.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Smartphone-assisted manual marking significantly improves the accuracy of manual marking alone when comparing with the Verion Digital Marker system for toric IOL implantation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_987_19","type":"journal-article","created":{"date-parts":[[2020,2,20]],"date-time":"2020-02-20T00:59:49Z","timestamp":1582160389000},"page":"455-458","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":14,"title":["Verion digital marking versus smartphone-assisted manual marking and isolated manual marking in toric intraocular lens implantation"],"prefix":"10.4103","volume":"68","author":[{"given":"Zain Irfan","family":"Khatib","sequence":"first","affiliation":[{"name":"Laxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suhas S","family":"Haldipurkar","sequence":"additional","affiliation":[{"name":"Laxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijay","family":"Shetty","sequence":"additional","affiliation":[{"name":"Laxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,2,14]]},"reference":[{"key":"R1-20251013","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/j.jcjo.2014.02.001","article-title":"Changes in corneal astigmatism among patients with visually significant cataract","volume":"49","author":"Lyall","year":"2014","journal-title":"Can J Ophthalmol"},{"key":"R2-20251013","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/536412","article-title":"Prevalence of corneal astigmatism in patients before cataract surgery in Northern China","volume":"2014","author":"Yuan","year":"2014","journal-title":"J Ophthalmol"},{"key":"R3-20251013","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1111\/j.1755-3768.1994.tb02729.x","article-title":"Cataract patients in a defined Swedish population 1986\u20131990 II Preoperative observations","volume":"72","author":"Ninn-Pedersen","year":"1994","journal-title":"Acta Ophthalmol (Copenh)"},{"key":"R4-20251013","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/S0002-9394(14)74917-7","article-title":"Biometry of 7500 cataractous eyes","volume":"90","author":"Hoffer","year":"1980","journal-title":"Am J Ophthalmol"},{"key":"R5-20251013","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1016\/j.jcrs.2011.02.024","article-title":"Accuracy of toric intraocular lens implantation in cataract and refractive surgery","volume":"37","author":"Visser","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R6-20251013","first-page":"57","article-title":"Evaluation of a new electronic pre-operative reference marker for toric IOL implantation by two different methods of analysis: Adobe photoshop versus iTrace","volume":"2","author":"Farooqui","year":"2015","journal-title":"Adv Ophthalmol Vis Syst"},{"key":"R7-20251013","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.jcrs.2008.04.041","article-title":"Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation","volume":"34","author":"Ma","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R8-20251013","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.jcrs.2009.08.033","article-title":"Assessment of toric intraocular lens alignment by a refractive power\/corneal analyzer system and slitlamp observation","volume":"36","author":"Carey","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R9-20251013","doi-asserted-by":"crossref","first-page":"375","DOI":"10.3928\/1081597X-20101005-01","article-title":"New axis-marking method for a toric intraocular lens: Mapping method","volume":"27","author":"Cha","year":"2011","journal-title":"J Refract Surg"},{"key":"R10-20251013","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.jcrs.2017.03.041","article-title":"Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery","volume":"43","author":"Webers","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R11-20251013","first-page":"150","article-title":"Evaluation of the accuracy of two marking methods and the novel toriCAM application for toric intraocular lens alignment","volume":"34","author":"Pallas","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R12-20251013","doi-asserted-by":"crossref","first-page":"1949","DOI":"10.1016\/j.jcrs.2014.09.029","article-title":"Simple technique to measure toric intraocular lens alignment and stability using a smartphone","volume":"40","author":"Teichman","year":"2014","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_987_19","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:30:21Z","timestamp":1787758221000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_987_19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,14]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_987_19","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,14]]},"assertion":[{"value":"2019-05-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-09-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}