{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T12:21:36Z","timestamp":1788351696466,"version":"build-2803163510"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To evaluate the adaptation of a small diameter glass fiber post in minimally prepared root canals and to compare two taper configurations (4% and 7%) within the framework of minimally invasive endodontics (MIE).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Twenty standardized resin canal models with identical internal anatomy were assigned to two groups (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 10): Group 1 (4% taper; R-Motion, FKG Dentaire) and Group 2 (7% taper; WaveOne Gold Primary, Dentsply Sirona). Following a formal power analysis to establish sample size validity, root canals were prepared according to manufacturers\u2019 parameters and obturated using standard warm vertical compaction with an epoxy-resin based sealer (ADSEAL, Meta Biomed). Postspace patterns were fabricated using an autopolymerizing acrylic resin. A prefabricated glass fiber post (0.95 mm; Itena Clinical) served as the reference control. All experimental patterns and the reference post were scanned using a high-precision TRIOS intraoral scanner (3Shape). Digital superimposition was conducted using best-fit alignment algorithms in 3D analysis software, and root mean square (RMS) values were calculated to verify alignment accuracy. Cross-sectional post diameters were measured at five standardized levels (\u22125 mm\u2013\u22129 mm from the working length). Data normality was verified via the Shapiro\u2013Wilk test, and differences between groups and the reference post were evaluated using Student\u2019s\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test and Wilcoxon signed-rank test (\u03b1 = 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Low mean RMS values confirmed excellent digital alignment accuracy across both groups (7% group: 0.0615 \u00b1 0.029 mm and 4% group: 0.1496 \u00b1 0.088 mm). At all five evaluated cross-sectional levels (\u22125, \u22126, \u22127, \u22128, and \u22129 mm), the canal-derived diameters were significantly smaller than the 0.95 mm reference post (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01). While the 7% taper configuration yielded significantly larger internal dimensions than the 4% configuration at all levels, neither taper configuration allowed passive adaptation of the fiber post. Consequently, none of the specimens could accommodate the reference post without secondary mechanical enlargement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Minimally invasive canal preparations utilizing 4% and 7% tapers effectively preserve radicular dentin structural integrity but do not provide sufficient physical space to accommodate standard small diameter (0.95 mm) glass fiber posts. To successfully bridge this gap without sacrificing the biological benefits of conservative endodontics, a balanced approach combining apical preservation with highly controlled coronal modification is required. Alternatively, the dental industry must develop reduced-taper, smaller-diameter fiber posts that match contemporary minimal-preparation file dimensions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcde.jcde_531_26","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T14:00:22Z","timestamp":1788184822000},"page":"1012-1017","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Impact of minimal taper canal preparation on the adaptation of glass fiber posts"],"prefix":"10.4103","volume":"29","author":[{"given":"Rosine Hajj","family":"Chehad\u00e9","sequence":"first","affiliation":[{"name":"Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Afram","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascale","family":"Habre","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roula","family":"El Hachem","sequence":"additional","affiliation":[{"name":"Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Zogheib","sequence":"additional","affiliation":[{"name":"Department of Endodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samar Abou","family":"Jaoud\u00e9","sequence":"additional","affiliation":[{"name":"Department of Oral Medicine and Radiology, Saint Joseph University of Beirut, Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,31]]},"reference":[{"key":"R1-20260902","doi-asserted-by":"crossref","first-page":"282","DOI":"10.4103\/0972-0707.114342","article-title":"Minimally invasive dentistry (endodontics)","volume":"16","author":"Gutmann","year":"2013","journal-title":"J Conserv Dent"},{"key":"R2-20260902","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1038\/sj.bdj.2017.672","article-title":"Contemporary operative caries management: Consensus recommendations on minimally invasive caries removal","volume":"223","author":"Banerjee","year":"2017","journal-title":"Br Dent J"},{"key":"R3-20260902","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.joen.2020.10.010","article-title":"Combination of nonsurgical endodontic and vital pulp therapy for management of mature permanent mandibular molar teeth with symptomatic irreversible pulpitis and apical periodontitis","volume":"47","author":"Koli","year":"2021","journal-title":"J Endod"},{"key":"R4-20260902","first-page":"259","article-title":"Preventive restorative dentistry","volume":"40","author":"Christensen","year":"1990","journal-title":"Int Dent J"},{"key":"R5-20260902","first-page":"1117","article-title":"Fracture resistance of endodontically treated teeth restored with post and core: A systematic review","volume":"46","author":"Taha","year":"2020","journal-title":"J Endod"},{"key":"R6-20260902","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/jbm.b.30508","article-title":"The effect of fiber insertion on fracture resistance of endodontically treated molars with MOD cavity and reattached fractured lingual cusps","volume":"79","author":"Belli","year":"2006","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R7-20260902","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1111\/j.1365-2591.2006.01078.x","article-title":"How does canal taper affect root stresses?","volume":"39","author":"Rundquist","year":"2006","journal-title":"Int Endod J"},{"key":"R8-20260902","first-page":"128","article-title":"Influence of bioceramic sealer on the fracture resistance of endodontically treated teeth: A comparative in vitro study","volume":"44","author":"Kim","year":"2018","journal-title":"J Endod"},{"key":"R9-20260902","first-page":"460","article-title":"Theory and practice of minimally invasive endodontics","volume":"51","author":"Jiang","year":"2016","journal-title":"Zhonghua Kou Qiang Yi Xue Za Zhi"},{"key":"R10-20260902","first-page":"540","article-title":"Impact of WaveOne gold and reciproc blue on environmental dentin preservation","volume":"21","author":"Zogheib","year":"2018","journal-title":"J Conserv Dent"},{"key":"R11-20260902","doi-asserted-by":"crossref","first-page":"179","DOI":"10.4103\/jispcd.JISPCD_88_18","article-title":"Impact of minimal root canal taper on the fracture resistance of endodontically treated bicuspids","volume":"8","author":"Zogheib","year":"2018","journal-title":"J Int Soc Prev Community Dent"},{"key":"R12-20260902","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1016\/j.joen.2017.01.022","article-title":"Fracture resistance of endodontically treated teeth with different access cavity designs","volume":"43","author":"Plotino","year":"2017","journal-title":"J Endod"},{"key":"R13-20260902","doi-asserted-by":"crossref","first-page":"207","DOI":"10.2334\/josnusd.24-0098","article-title":"Clinical behavior and survival of endodontically treated teeth with or without post placement: A systematic review and meta-analysis","volume":"66","author":"Alenezi","year":"2024","journal-title":"J Oral Sci"},{"key":"R14-20260902","first-page":"15B","article-title":"Clinical evaluation of fiber-reinforced epoxy resin posts and cast post and cores","volume":"13","author":"Ferrari","year":"2000","journal-title":"Am J Dent"},{"key":"R15-20260902","doi-asserted-by":"crossref","first-page":"58","DOI":"10.4103\/0970-9290.131126","article-title":"Randomized clinical study comparing metallic and glass fiber post in restoration of endodontically treated teeth","volume":"25","author":"Gbadebo","year":"2014","journal-title":"Indian J Dent Res"},{"key":"R16-20260902","first-page":"129","article-title":"Evaluation of the adhesion of fiber posts to intraradicular dentin","volume":"7","author":"Goracci","year":"2005","journal-title":"J Adhes Dent"},{"key":"R17-20260902","doi-asserted-by":"crossref","first-page":"29","DOI":"10.4103\/JCD.JCD_599_20","article-title":"Effects of ultrasonic refinement on endodontic access cavity walls: A microcomputed tomography analysis","volume":"24","author":"Zogheib","year":"2021","journal-title":"J Conserv Dent"},{"key":"R18-20260902","first-page":"733","article-title":"Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature-Part 1. Composition and micro- and macrostructure alterations","volume":"38","author":"DIETSCHI","year":"2007","journal-title":"In: Quintessence international"},{"key":"R19-20260902","first-page":"309","article-title":"Comparison between two different methods for testing the bonded interface of fiber posts into root canals","volume":"36","author":"Vichi","year":"2008","journal-title":"J Dent"},{"key":"R20-20260902","first-page":"141","article-title":"Resin cement thickness in oval-shaped canals: Hourglass versus 0.04 taper preparations","volume":"13","author":"Coniglio","year":"2011","journal-title":"J Adhes Dent"},{"key":"R21-20260902","doi-asserted-by":"crossref","first-page":"808","DOI":"10.5005\/jp-journals-10024-2340","article-title":"Impact of the root canal taper on the apical adaptability of sealers used in a single-cone technique: A micro-computed tomography study","volume":"19","author":"Germain","year":"2018","journal-title":"J Contemp Dent Pract"},{"key":"R22-20260902","first-page":"75","article-title":"Fatigue resistance and structural characteristics of fiber posts: Three-body wear test and SEM images","volume":"113","author":"Grandini","year":"2005","journal-title":"Eur J Oral Sci"},{"key":"R23-20260902","first-page":"101","article-title":"Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors","volume":"26","author":"Abduo","year":"2018","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"R24-20260902","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1111\/j.1365-2591.2012.02113.x","article-title":"Should pulp chamber pulpotomy be seen as a permanent treatment? Some preliminary thoughts","volume":"46","author":"Simon","year":"2013","journal-title":"Int Endod J"},{"key":"R25-20260902","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.3390\/bioengineering10111331","article-title":"Evaluation of the impact of calcium silicate-based sealer insertion technique on root canal obturation quality: A micro-computed tomography study","volume":"10","author":"Sfeir","year":"2023","journal-title":"Bioengineering (Basel)"},{"key":"R26-20260902","first-page":"1534","article-title":"Comparison of cyclic fatigue resistance and geometric variables of different nickel-titanium instruments","volume":"53","author":"Pedull\u00e0","year":"2020","journal-title":"Int Endod"},{"key":"R27-20260902","first-page":"11","article-title":"Full arch scans: Conventional versus digital impressions-an in-vitro study","volume":"14","author":"Ender","year":"2011","journal-title":"Int J Comput Dent"},{"key":"R28-20260902","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.ajodo.2013.04.017","article-title":"Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner","volume":"144","author":"Fl\u00fcgge","year":"2013","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R29-20260902","first-page":"462","article-title":"An in vitro evaluation of the anatomical adaptation of prefabricated fiber posts to root canal walls","volume":"17","author":"Teixeira","year":"2008","journal-title":"J Prosthodont"},{"key":"R30-20260902","first-page":"331","article-title":"The effect of different post space preparation techniques on the bond strength of fiber posts to root dentin","volume":"9","author":"Schmage","year":"2006","journal-title":"J Conserv Dent"},{"key":"R31-20260902","first-page":"577","article-title":"Effect of three post space preparation techniques on the retention of a prefabricated fiber post","volume":"88","author":"Hagge","year":"2002","journal-title":"J Prosthet Dent"},{"key":"R32-20260902","first-page":"379","article-title":"Influence of preparation taper and cement thickness on the push-out bond strength of customized fiber posts","volume":"14","author":"D'Arcangelo","year":"2012","journal-title":"J Adhes Dent"},{"key":"R33-20260902","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.dental.2005.04.018","article-title":"Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review","volume":"21","author":"Braga","year":"2005","journal-title":"Dent Mater"},{"key":"R34-20260902","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/S0109-5641(02)00030-1","article-title":"Microtensile bond strength between adhesive cements and root canal dentin","volume":"19","author":"Bouillaguet","year":"2003","journal-title":"Dent Mater"},{"key":"R35-20260902","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1111\/iej.12636","article-title":"Dissolution, dislocation and dimensional changes of endodontic sealers after a solubility challenge: a micro-CT approach","volume":"50","author":"Silva","year":"2017","journal-title":"Int Endod J"},{"key":"R36-20260902","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1111\/j.1365-2591.2010.01840.x","article-title":"Quality of thermoplasticized and single point root fillings assessed by micro-computed tomography","volume":"44","author":"Somma","year":"2011","journal-title":"Int Endod J"},{"key":"R37-20260902","first-page":"312","article-title":"Reconstruction of endodontically treated posterior teeth\u2014with or without post? Guidelines for the dental practitioner","volume":"4","author":"Zarow","year":"2009","journal-title":"Eur J Esthet Dent"}],"container-title":["Journal of Conservative Dentistry and Endodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/JCDE.JCDE_531_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T12:00:35Z","timestamp":1788350435000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/JCDE.JCDE_531_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,31]]},"references-count":37,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jcde.jcde_531_26","relation":{},"ISSN":["2950-4716","2950-4708"],"issn-type":[{"value":"2950-4716","type":"print"},{"value":"2950-4708","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,31]]},"assertion":[{"value":"2026-05-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}