{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T23:30:30Z","timestamp":1788564630943,"version":"build-2803163510"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>This study aimed to evaluate the influence of autoclave sterilization on the cyclic fatigue resistance of nickel\u2013titanium (NiTi) endodontic files with different NiTi alloy treatments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methodology:<\/jats:title>\n                    <jats:p>The research examined Hyflex CM, Bassi Logic, TruNatomy, and ProTaper Gold files, which were divided into control, conventional sterilization, and flash sterilization groups. Poststerilization, the instruments were tested using a custom-made Dynamic Cyclic Fatigue Testing Device replicating root canal procedures. Group 1 used HyFlex CM (size 25, taper 0.04), Group 2 used Bassi Logic (size 25, taper 0.04), Group 3 used TruNatomy (size 25, taper 0.04), and Group 4 used ProTaper Gold (size F1). After rotating each instrument until it fractured, the number of cycles to failure was determined and the time to fracture was noted.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis:<\/jats:title>\n                    <jats:p>\n                      Statistical analysis was conducted using SPSS 26.0 (Statistical software developed by IBM) with one-way ANOVA and Tukey honestly significant difference\n                      <jats:italic toggle=\"yes\">post hoc<\/jats:italic>\n                      tests.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>HyFlex CM had the highest fracture resistance, whereas ProTaper Gold had the lowest. Sterilization increased the cyclic fatigue resistance of HyFlex CM, Bassi Logic, and ProTaper Gold but decreased that of TruNatomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The study concluded that sterilization enhances cyclic fatigue resistance, except for TruNatomy files, and emphasized understanding NiTi alloy properties to mitigate instrument failure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcde.jcde_767_24","type":"journal-article","created":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T17:53:33Z","timestamp":1743702813000},"page":"314-318","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Analysis of dynamic cyclic fatigue resistance of different endodontic nickel\u2013titanium instruments with different sterilization methods: An in vitro study"],"prefix":"10.4103","volume":"28","author":[{"given":"Neeta","family":"Patel","sequence":"first","affiliation":[{"name":"Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akshayraj Kantilal","family":"Langaliya","sequence":"additional","affiliation":[{"name":"Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shwetika","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anjali Kairav","family":"Kothari","sequence":"additional","affiliation":[{"name":"Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gunja","family":"Malaviya","sequence":"additional","affiliation":[{"name":"Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siddharth","family":"Yadav","sequence":"additional","affiliation":[{"name":"Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,3]]},"reference":[{"key":"R1-20250403","doi-asserted-by":"crossref","first-page":"199","DOI":"10.4103\/0972-0707.181925","article-title":"Advances in endodontics:Potential applications in clinical practice","volume":"19","author":"Kishen","year":"2016","journal-title":"J Conserv Dent"},{"key":"R2-20250403","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1007\/s00784-018-2566-z","article-title":"Changes in periapical status, quality of root fillings and estimated endodontic treatment need in a similar urban German population 20 years later","volume":"23","author":"Connert","year":"2019","journal-title":"Clin Oral Investig"},{"key":"R3-20250403","doi-asserted-by":"crossref","first-page":"126","DOI":"10.4103\/JCDE.JCDE_248_23","article-title":"Revolutionizing endodontics:Advancements in nickel-titanium instrument surfaces","volume":"27","author":"Agrawal","year":"2024","journal-title":"J Conserv Dent Endod"},{"key":"R4-20250403","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.5005\/jp-journals-10024-2181","article-title":"Evolution of nickel-titanium alloys in endodontics","volume":"18","author":"Ounsi","year":"2017","journal-title":"J Contemp Dent Pract"},{"key":"R5-20250403","first-page":"111","article-title":"Nickel-titanium rotary file systems:What's new?","volume":"4","author":"Tabassum","year":"2019","journal-title":"Eur Endod J"},{"key":"R6-20250403","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.joen.2012.11.005","article-title":"Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments","volume":"39","author":"Shen","year":"2013","journal-title":"J Endod"},{"key":"R7-20250403","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00004770-200003000-00008","article-title":"Defects in rotary nickel-titanium files after clinical use","volume":"26","author":"Sattapan","year":"2000","journal-title":"J Endod"},{"key":"R8-20250403","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1111\/iej.12353","article-title":"Deformation of HyFlex CM instruments and their shape recovery following heat sterilization","volume":"48","author":"Alfoqom Alazemi","year":"2015","journal-title":"Int Endod J"},{"key":"R9-20250403","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1097\/00004770-200206000-00007","article-title":"Cyclic fatigue of endodontic nickel titanium rotary instruments:Static and dynamic tests","volume":"28","author":"Li","year":"2002","journal-title":"J Endod"},{"key":"R10-20250403","doi-asserted-by":"crossref","first-page":"e811","DOI":"10.1002\/cre2.811","article-title":"Impact of pecking amplitude on cyclic fatigue of new nickel-titanium files","volume":"10","author":"Pedull\u00e0","year":"2024","journal-title":"Clin Exp Dent Res"},{"key":"R11-20250403","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1111\/iej.12790","article-title":"Effect of interrupted motion on the cyclic fatigue resistance of reciprocating nickel-titanium instruments","volume":"51","author":"Keskin","year":"2018","journal-title":"Int Endod J"},{"key":"R12-20250403","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1111\/iej.12758","article-title":"Resistance to cyclic fatigue of PathFile, ScoutRaCe and ProGlider glide path files in an S-shaped canal","volume":"51","author":"Top\u00e7uo\u011flu","year":"2018","journal-title":"Int Endod J"},{"key":"R13-20250403","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1016\/j.joen.2011.08.011","article-title":"Influence of different manufacturing methods on the cyclic fatigue of rotary nickel-titanium endodontic instruments","volume":"37","author":"Rodrigues","year":"2011","journal-title":"J Endod"},{"key":"R14-20250403","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.joen.2016.10.044","article-title":"A comparison of the cyclic fatigue resistance of used and new glide path files","volume":"43","author":"\u00d6zy\u00fcrek","year":"2017","journal-title":"J Endod"},{"key":"R15-20250403","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/0030-4220(86)90186-6","article-title":"The effects of cyclical axial motion on rotary endodontic instrument fatigue","volume":"61","author":"Dederich","year":"1986","journal-title":"Oral Surg Oral Med Oral Pathol"},{"key":"R16-20250403","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/S0099-2399(97)80344-5","article-title":"Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files","volume":"23","author":"Silvaggio","year":"1997","journal-title":"J Endod"},{"key":"R17-20250403","doi-asserted-by":"crossref","first-page":"440","DOI":"10.4103\/jcd.jcd_182_21","article-title":"Effect of autoclaving on the cyclic fatigue resistance of nickel-titanium rotary instruments:An in vitro study","volume":"24","author":"Gayatri","year":"2021","journal-title":"J Conserv Dent"},{"key":"R18-20250403","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1016\/j.joen.2022.08.004","article-title":"Fracture resistance of heat-treated nickel-titanium rotary files after usage and autoclave sterilization:An in vitro study","volume":"48","author":"El Abed","year":"2022","journal-title":"J Endod"},{"key":"R19-20250403","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1111\/iej.12550","article-title":"Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated nickel-titanium instruments","volume":"49","author":"Zhao","year":"2016","journal-title":"Int Endod J"},{"key":"R20-20250403","first-page":"468","article-title":"Cyclic fatigue resistance of WaveOne gold, ProDesign R and ProDesign logic files in curved canals in vitro","volume":"12","author":"de Menezes","year":"2017","journal-title":"Iran Endod J"},{"key":"R21-20250403","doi-asserted-by":"crossref","first-page":"95","DOI":"10.4103\/JCDE.JCDE_204_23","article-title":"Analysis of cyclic fatigue resistance of different endodontic nickel-titanium rotary instruments:An in vitro study","volume":"27","author":"Langaliya","year":"2024","journal-title":"J Conserv Dent Endod"},{"key":"R22-20250403","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.joen.2014.02.005","article-title":"Cyclic fatigue resistance of nickel-titanium instruments after immersion in irrigant solutions with or without surfactants","volume":"40","author":"Pedull\u00e0","year":"2014","journal-title":"J Endod"},{"key":"R23-20250403","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1016\/j.joen.2013.07.020","article-title":"Cyclic fatigue resistance of K3, K3XF, and twisted file nickel-titanium files under continuous rotation or reciprocating motion","volume":"39","author":"P\u00e9rez-Higueras","year":"2013","journal-title":"J Endod"},{"key":"R24-20250403","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1111\/j.1365-2591.2006.01143.x","article-title":"Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems","volume":"39","author":"Grande","year":"2006","journal-title":"Int Endod J"}],"container-title":["Journal of Conservative Dentistry and Endodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/JCDE.JCDE_767_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:00:31Z","timestamp":1786647631000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/JCDE.JCDE_767_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcde.jcde_767_24","relation":{},"ISSN":["2950-4716","2950-4708"],"issn-type":[{"value":"2950-4716","type":"print"},{"value":"2950-4708","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-10-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}