{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T15:33:28Z","timestamp":1747755208547},"reference-count":23,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>A 60-year-old Caucasian male with a long history of cigarette smoking was diagnosed with epidermal growth factor receptor-mutation negative lung adenocarcinoma. The single cerebral metastasis in the right frontal lobe was treated with stereotactic radiosurgery and systemic chemotherapies. Normalized subtraction (NS) method was used to evaluate the serial brain magnetic resonance (MR) and fludeoxyglucose-positron emission tomography (FDG-PET) findings retrospectively, and the potential benefit of concurrent NS of serial MR images (MRIs) and PET images was demonstrated. MIM 4.1 (MIM Software Inc., Cleveland, OH) was used to co-register MRI with PET data and to perform NS on the serial MRI and PET data. MIM 4.1 provides fully automated alignment of imaging data by maximization of mutual information. Cortical regions distant from the brain lesion were used to adjust for the intensity differences between scans, so the voxel differences in normal brain regions were near zero in the NS images. A difference of 15% or greater in voxel densities was used for both MRI and PET, above or below which a change in MR signal intensity and FDG avidity was considered significant. The use of NS, in this case, allowed for an enhanced correlation of morphologic and functional information, which may have added value in the early treatment monitoring of brain tumors and help distinguish recurrent tumor from postradiation changes.<\/jats:p>","DOI":"10.4103\/jcis.jcis_14_18","type":"journal-article","created":{"date-parts":[[2018,6,28]],"date-time":"2018-06-28T09:32:27Z","timestamp":1530178347000},"page":"25","update-policy":"http:\/\/dx.doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Normalized Subtraction of Serial Brain Magnetic Resonance Images and Fludeoxyglucose-Positron Emission Tomography Images for Tumor Treatment Monitoring: Case Report and Method Description"],"prefix":"10.25259","volume":"8","author":[{"given":"Nghi C","family":"Nguyen","sequence":"first","affiliation":[{"name":"Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Medhat M","family":"Osman","sequence":"additional","affiliation":[{"name":"Department of Radiology, Saint Louis University, Saint Louis, Missouri, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2018,6,28]]},"reference":[{"key":"10.4103\/jcis.JCIS_14_18\/ref-1","first-page":"45","article-title":"Radiation injury of the brain","volume":"12","author":"Valk","year":"1991","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-2","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1002\/ijc.1016","article-title":"The sensitivity and specificity of FDG PET in distinguishing recurrent brain tumor from radionecrosis in patients treated with stereotactic radiosurgery","volume":"96","author":"Chao","year":"2001","journal-title":"Int J Cancer"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-3","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1109\/TMI.2007.892508","article-title":"Brain functional localization: A survey of image registration techniques","volume":"26","author":"Gholipour","year":"2007","journal-title":"IEEE Trans Med Imaging"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-4","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1001\/archneur.1993.00540060011007","article-title":"The effect of repositioning error on serial magnetic resonance imaging scans","volume":"50","author":"Goodkin","year":"1993","journal-title":"Arch Neurol"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-5","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1097\/00130404-200407000-00004","article-title":"PET and brain tumor image fusion","volume":"10","author":"Wong","year":"2004","journal-title":"Cancer J"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-6","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1212\/WNL.45.9.1684","article-title":"Correlating MRI and clinical disease activity in multiple sclerosis: Relevance of hypointense lesions on short-TR\/short-TE (T1-weighted) spin-echo images","volume":"45","author":"van Walderveen","year":"1995","journal-title":"Neurology"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-7","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1007\/s002340050860","article-title":"Visual analysis of serial T2-weighted MRI in multiple sclerosis: Intra- and interobserver reproducibility","volume":"41","author":"Molyneux","year":"1999","journal-title":"Neuroradiology"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-8","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1007\/s002340050335","article-title":"Use of subvoxel registration and subtraction to improve demonstration of contrast enhancement in MRI of the brain","volume":"38","author":"Curati","year":"1996","journal-title":"Neuroradiology"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-9","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1053\/crad.2002.1103","article-title":"Subvoxel image registration of multislice (2D) magnetic resonance images in patients with high-grade gliomas of the brain","volume":"57","author":"Oatridge","year":"2002","journal-title":"Clin Radiol"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-10","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1097\/00004728-199307000-00004","article-title":"MRI-PET registration with automated algorithm","volume":"17","author":"Woods","year":"1993","journal-title":"J Comput Assist Tomogr"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-11","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1148\/radiol.2016161172","article-title":"FDG PET\/MR imaging coregistration helps predict survival in patients with glioblastoma and radiologic progression after standard of care treatment","volume":"283","author":"Leiva-Salinas","year":"2017","journal-title":"Radiology"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-12","doi-asserted-by":"crossref","first-page":"29","DOI":"10.2967\/jnumed.111.092387","article-title":"3\u2019-deoxy-3\u2019-18F-fluorothymidine PET and MRI for early survival predictions in patients with recurrent malignant glioma treated with bevacizumab","volume":"53","author":"Schwarzenberg","year":"2012","journal-title":"J Nucl Med"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-13","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1148\/radiology.174.1.2294579","article-title":"Meninges: Benign postoperative enhancement on MR images","volume":"174","author":"Burke","year":"1990","journal-title":"Radiology"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-14","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1148\/radiology.174.1.2294578","article-title":"Cranial postoperative site: Assessment with contrast-enhanced MR imaging","volume":"174","author":"Elster","year":"1990","journal-title":"Radiology"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-15","doi-asserted-by":"crossref","first-page":"2061","DOI":"10.1007\/s00330-004-2391-4","article-title":"Magnetic resonance image registration and subtraction in the assessment of minor changes in low grade glioma volume","volume":"14","author":"Connor","year":"2004","journal-title":"Eur Radiol"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-16","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1007\/s00415-002-0712-6","article-title":"Image registration and subtraction to detect active T (2) lesions in MS: An interobserver study","volume":"249","author":"Tan","year":"2002","journal-title":"J Neurol"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-17","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1148\/radiol.2501080480","article-title":"Subtraction MR images in a multiple sclerosis multicenter clinical trial setting","volume":"250","author":"Moraal","year":"2009","journal-title":"Radiology"},{"issue":"Pt 10","key":"10.4103\/jcis.JCIS_14_18\/ref-18","doi-asserted-by":"crossref","first-page":"2150","DOI":"10.1093\/brain\/123.10.2150","article-title":"Opposite ictal perfusion patterns of subtracted SPECT. Hyperperfusion and hypoperfusion","volume":"123","author":"Lee","year":"2000","journal-title":"Brain"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-19","doi-asserted-by":"crossref","first-page":"1802","DOI":"10.1093\/brain\/awh534","article-title":"Postoperative alteration of cerebral glucose metabolism in mesial temporal lobe epilepsy","volume":"128","author":"Joo","year":"2005","journal-title":"Brain"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-20","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1002\/jmri.22801","article-title":"Comparison of 3 tesla proton MR spectroscopy, MR perfusion and MR diffusion for distinguishing glioma recurrence from posttreatment effects","volume":"35","author":"Fink","year":"2012","journal-title":"J Magn Reson Imaging"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-21","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1093\/neuonc\/nor075","article-title":"Differentiating treatment-induced necrosis from recurrent\/progressive brain tumor using nonmodel-based semiquantitative indices derived from dynamic contrast-enhanced T1-weighted MR perfusion","volume":"13","author":"Narang","year":"2011","journal-title":"Neuro Oncol"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-22","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1006\/nimg.2000.0651","article-title":"Statistical parametric mapping: Assessment of application in children","volume":"12","author":"Muzik","year":"2000","journal-title":"Neuroimage"},{"key":"10.4103\/jcis.JCIS_14_18\/ref-23","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1089\/neu.2006.0203","article-title":"Statistical image analysis of cerebral glucose metabolism in patients with cognitive impairment following diffuse traumatic brain injury","volume":"24","author":"Kato","year":"2007","journal-title":"J Neurotrauma"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/normalized-subtraction-of-serial-brain-magnetic-resonance-images-and-fludeoxyglucose-positron-emission-tomography-images-for-tumor-treatment-monitoring-case-report-and-method-description\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/normalized-subtraction-of-serial-brain-magnetic-resonance-images-and-fludeoxyglucose-positron-emission-tomography-images-for-tumor-treatment-monitoring-case-report-and-method-description\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,16]],"date-time":"2019-08-16T11:58:04Z","timestamp":1565956684000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/normalized-subtraction-of-serial-brain-magnetic-resonance-images-and-fludeoxyglucose-positron-emission-tomography-images-for-tumor-treatment-monitoring-case-report-and-method-description\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,28]]},"references-count":23,"alternative-id":["10.4103\/jcis.JCIS_14_18"],"URL":"https:\/\/doi.org\/10.4103\/jcis.jcis_14_18","relation":{},"ISSN":["2156-7514"],"issn-type":[{"value":"2156-7514","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,28]]},"article-number":"25"}}