{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:36:43Z","timestamp":1787773003719,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2024,8,16]],"date-time":"2024-08-16T00:00:00Z","timestamp":1723766400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>In recent years, advances in radiotherapy technology have led to the use of high-precision radiotherapy such as volumetric modulated arc therapy (VMAT). Total body irradiation using VMAT technique (VMAT-TBI) was performed for the first time in our hospital. A 56-year-old male patient diagnosed with B-cell acute lymphoblastic leukemia was performed TBI as pretreatment for haploidentical-related peripheral blood stem-cell transplantation. The prescribed dose was 4 Gy for planning target volume in two fractions. The treatment plan was divided into two plans: upper body and lower body with three and two isocenters, respectively. The overall treatment time with VMAT-TBI was approximately 55 min, and it was not significantly longer than that of moving couch techniques. VMAT-TBI is a less burdensome and more accurate treatment for patients, and it may be a useful treatment for TBI.<\/jats:p>","DOI":"10.4103\/jcrt.jcrt_1067_23","type":"journal-article","created":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T12:10:46Z","timestamp":1724933446000},"page":"237-239","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["First clinical experience of total body irradiation using volumetric modulated arc therapy technique in Japan"],"prefix":"10.4103","volume":"21","author":[{"given":"Yuki","family":"Nozawa","sequence":"first","affiliation":[{"name":"Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideomi","family":"Yamashita","sequence":"additional","affiliation":[{"name":"Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Subaru","family":"Sawayanagi","sequence":"additional","affiliation":[{"name":"Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsuto","family":"Katano","sequence":"additional","affiliation":[{"name":"Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,8,16]]},"reference":[{"key":"R1-20250403","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.critrevonc.2018.01.011","article-title":"Total body irradiation in allogeneic bone marrow transplantation conditioning regimens: A review","volume":"123","author":"Paix","year":"2018","journal-title":"Crit Rev Oncol Hematol"},{"key":"R2-20250403","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.ijrobp.2018.04.071","article-title":"Total body irradiation: Guidelines from the international lymphoma radiation oncology group (ILROG)","volume":"101","author":"Wong","year":"2018","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R3-20250403","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1088\/0031-9155\/39\/1\/002","article-title":"A translating-bed technique for total-body irradiation","volume":"39","author":"Gerig","year":"1994","journal-title":"Phys Med Biol"},{"key":"R4-20250403","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.radonc.2018.08.005","article-title":"Total-body irradiation using linac-based volumetric modulated arc therapy: Its clinical accuracy, feasibility and reliability","volume":"129","author":"Tas","year":"2018","journal-title":"Radiother Oncol"},{"key":"R5-20250403","doi-asserted-by":"crossref","first-page":"785917","DOI":"10.3389\/fonc.2022.785917","article-title":"Optimized conformal total body irradiation methods with helical tomotherapy and elekta VMAT: Implementation, imaging, planning and dose delivery for pediatric patients","volume":"12","author":"Loginova","year":"2022","journal-title":"Front Oncol"},{"key":"R6-20250403","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13014-016-0625-7","article-title":"Total body irradiation with volumetric modulated arc therapy: Dosimetric data and first clinical experience","volume":"11","author":"Springer","year":"2016","journal-title":"Radiat Oncol"},{"key":"R7-20250403","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1186\/s13014-019-1445-3","article-title":"Novel rotatable tabletop for total-body irradiation using a linac-based VMAT technique","volume":"14","author":"Losert","year":"2019","journal-title":"Radiat Oncol"},{"key":"R8-20250403","first-page":"113","article-title":"Volumetric modulated arc therapy enabled total body irradiation (VMAT-TBI): Six-year clinical experience and treatment outcomes","volume":"28","author":"Zhang-Velten","year":"2022","journal-title":"Transplant Cell Ther"},{"key":"R9-20250403","first-page":"518","article-title":"Evaluation of volumetric modulated arc therapy (VMAT)-based total body irradiation (TBI) in pediatric patients","volume":"26","author":"Yaray","year":"2021","journal-title":"Rep Pract Oncol Radiother"},{"key":"R10-20250403","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1186\/s13014-021-01959-3","article-title":"Feasibility study of volumetric modulated arc therapy with Halcyon\u2122 linac for total body irradiation","volume":"16","author":"Uehara","year":"2021","journal-title":"Radiat Oncol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1067_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:15:02Z","timestamp":1787771702000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1067_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,16]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_1067_23","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,16]]},"assertion":[{"value":"2023-05-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-09-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}