{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T20:25:05Z","timestamp":1788207905356,"version":"build-2803163510"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Linear accelerator (LINAC) embedded with kV source\u2013imager system is capable to do image-guided radiotherapy. The only disadvantage of cone-beam computed tomography image acquisition during treatment is the extra radiation dose to the patient. The aim of this study is to optimize the CBCT imaging doses likely to be received by the patient undergoing radiotherapy without affecting image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>The imaging dose to the patient was estimated on CTDI phantoms. The effect of additional filters of different materials (copper, brass, aluminum of thickness 0.1 mm each) was evaluated to find the optimized dose imaging technique. For the pelvis, a single imaging protocol available on the machine was used, whereas for the head and neck region, two protocols, high-quality head and standard-dose head were used. The image quality was assessed on CATPHAN-504 phantom using Owl CATPHAN\u00ae QA online tool. A new term \u201cImage Assessment score\u201d (IAS) was introduced to evaluate the image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Result:<\/jats:title>\n                    <jats:p>In the pelvis protocol, CBCT imaging doses with an additional 0.1-mm brass, copper, and aluminum filter were measured to be reduced by 7.1%, 4.7%, and 2.5%, respectively, whereas for high-quality head protocol, the dose reduction was 25.4% (with brass filter), 22% (with copper filter), and 3.1% (with aluminum filter). For the standard-dose head protocol, doses were reduced by 7.5%, 2.8%, and 2.1% with additional 0.1-mm brass copper and aluminum filters, respectively. Acceptable image quality was observed with all the filters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Although the reconstructed images were found somewhat noisier, they did not affect the purpose of imaging, that is, treatment position verification. It was observed that these extra filters further reduce the imaging dose without much affecting the image quality.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_1130_22","type":"journal-article","created":{"date-parts":[[2024,3,30]],"date-time":"2024-03-30T15:01:15Z","timestamp":1711810875000},"page":"71-78","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Cone-beam computed tomography (CBCT) dose optimization technique and image quality assessment scoring"],"prefix":"10.4103","volume":"20","author":[{"given":"Gaurav","family":"Trivedi","sequence":"first","affiliation":[{"name":"Department of Radiotherapy, PGIMER, Chandigarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pushpendra P.","family":"Singh","sequence":"additional","affiliation":[{"name":"Department of Physics, Indian Institute of Technology\u2014Ropar, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arun S.","family":"Oinam","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy, PGIMER, Chandigarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranjit","family":"Singh","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy, PGIMER, Chandigarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4,8]]},"reference":[{"key":"R1-20260507","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.ijrobp.2004.10.011","article-title":"Low-dose megavoltage cone-beam CT for radiation therapy","volume":"61","author":"Pouliot","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R2-20260507","doi-asserted-by":"crossref","first-page":"S66","DOI":"10.1259\/bjr\/68255935","article-title":"Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy","volume":"79","author":"Moore","year":"2006","journal-title":"Br J Radiol"},{"key":"R3-20260507","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.ijrobp.2009.09.041","article-title":"American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guidelines for image-guided radiation therapy (IGRT)","volume":"76","author":"Potters","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R4-20260507","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.prro.2013.01.004","article-title":"Safety considerations for IGRT:Executive summary","volume":"3","author":"Jaffray","year":"2013","journal-title":"Pract Radiat Oncol"},{"key":"R5-20260507","doi-asserted-by":"crossref","first-page":"4563","DOI":"10.1118\/1.2799489","article-title":"Kilovoltage imaging is more suitable than megavoltage imaging for guiding radiation therapy","volume":"34","author":"Xing","year":"2007","journal-title":"Med Phys"},{"key":"R6-20260507","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.radonc.2005.03.026","article-title":"Cone-beam-CT guided radiation therapy:A model for on-line application","volume":"75","author":"Oldham","year":"2005","journal-title":"Radiother Oncol"},{"key":"R7-20260507","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1016\/j.ijrobp.2004.07.709","article-title":"Online image-guided intensity-modulated radiotherapy for prostate cancer:How much improvement can we expect?A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery","volume":"60","author":"Ghilezan","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R8-20260507","doi-asserted-by":"crossref","first-page":"4041","DOI":"10.1118\/1.2775667","article-title":"The management of imaging dose during image-guided radiotherapy:Report of the AAPM Task Group 75","volume":"34","author":"Murphy","year":"2007","journal-title":"Med Phys"},{"key":"R9-20260507","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1259\/bjr\/37579222","article-title":"Simple methods to reduce patient dose in a Varian cone-beam CT system for delivery verification in pelvic radiotherapy","volume":"82","author":"Roxby","year":"2009","journal-title":"Br J Radiol"},{"key":"R10-20260507","doi-asserted-by":"crossref","first-page":"1511","DOI":"10.1016\/j.ijrobp.2008.03.070","article-title":"Estimation of setup uncertainty using planar and MVCT imaging for gynecologic malignancies","volume":"71","author":"Santanam","year":"2008","journal-title":"International Journal of Radiation Oncology*Biology*Physics"},{"key":"R11-20260507","doi-asserted-by":"crossref","first-page":"2191","DOI":"10.1088\/0031-9155\/51\/9\/005","article-title":"Cone-beam CT with zonal filters for simultaneous dose reduction, improved target contrast, and automated set-up in radiotherapy","volume":"51","author":"Moore","year":"2006","journal-title":"Phys Med Biol"},{"key":"R12-20260507","first-page":"133","article-title":"Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations","volume":"39","author":"Annkah","year":"2014","journal-title":"Journal of medical physics\/Association of Medical Physicists of India"},{"key":"R13-20260507","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.radonc.2007.10.035","article-title":"A quantitative image quality comparison study of four different image-guided radiotherapy devices","volume":"86","author":"St\u00fctzel","year":"2008","journal-title":"Radiother Oncol"},{"key":"R15-20260507","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1259\/bjr\/80446730","article-title":"Imaging doses from the Elekta Synergy X-ray cone-beam CT system","volume":"80","author":"Amer","year":"2007","journal-title":"Br J Radiol"},{"key":"R16-20260507","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.radonc.2007.10.014","article-title":"Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT):MV portal images vs. kV portal images vs. cone-beam CT","volume":"85","author":"Walter","year":"2007","journal-title":"Radiother Oncol"},{"key":"R17-20260507","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1259\/dmfr\/60375385","article-title":"Calculating effective dose on a cone-beam computed tomography device:3D Accuitomo and 3D Accuitomo FPD","volume":"37","author":"Lofthag-Hansen","year":"2008","journal-title":"Dentomaxillofac Radiol"},{"key":"R18-20260507","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1259\/dmfr\/16770531","article-title":"Image quality vs radiation dose of four cone-beam computed tomography scanners","volume":"37","author":"Loubele","year":"2008","journal-title":"Dentomaxillofac Radiol"},{"key":"R19-20260507","article-title":"Protection of patients in general radiography. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine, and radiotherapy Proceedings of an International Conference, International Atomic Energy Agency, Vienna (Austria)","author":"Rehani","year":"2001"},{"key":"R20-20260507","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1259\/bjr\/66519303","article-title":"Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner","volume":"79","author":"Mori","year":"2006","journal-title":"Br J Radiol"},{"key":"R21-20260507","doi-asserted-by":"crossref","first-page":"3989","DOI":"10.1088\/0031-9155\/50\/17\/005","article-title":"A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT):Cylindrical and anthropomorphic phantoms","volume":"50","author":"De Marco","year":"2005","journal-title":"Phys Med Biol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1130_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:39:23Z","timestamp":1787067563000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1130_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,8]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_1130_22","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,8]]},"assertion":[{"value":"2022-05-30","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-09-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}