{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T16:50:08Z","timestamp":1789145408400,"version":"build-2803163510"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>In this study, the dose distributions obtained by the algorithms used in Monaco treatment planning system (TPS) and Monte Carlo (MC) simulation were compared for small fields in the anthropomorphic RANDO phantom, and then, the results were analyzed using the gamma analysis method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>In the study, dose distributions obtained from the collapse cone algorithm, MC algorithm, and MC simulation were examined. The EGSnrc was utilized for MC simulation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In radiation fields smaller than 3 cm \u00d7 3 cm, the doses calculated by the CC algorithm are particularly high in the region of lung\/soft-tissue interfaces. In the region of soft-tissue\/vertebral interfaces, the doses calculated by the CC algorithm and the MC algorithm are compatible with the MC simulation. For each algorithm, the main reason for the non-overlapping dose curves in small fields compared to MC simulation is that the lateral electronic equilibrium loss is not taken into account by the algorithms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The doses calculated by the algorithms used in TPS may differ, especially in environments where density changes are sharp. Even if the radiation dose from different angles is calculated similarly in the target area by the algorithms, the calculated doses in the tissues in each radiation field path may be different. Therefore, to increase the quality of radiotherapy and to protect critical organs more accurately, the accuracy of the algorithms in TPS should be checked before treatment, especially in multi-field treatments such as stereotactic body radiation therapy and intensity-modulated radiotherapy for tumors in the abdominal region.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_1143_20","type":"journal-article","created":{"date-parts":[[2021,5,6]],"date-time":"2021-05-06T09:06:28Z","timestamp":1620291988000},"page":"1370-1375","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Monaco treatment planning system algorithms and Monte Carlo simulation for small fields in anthropomorphic RANDO phantom"],"prefix":"10.4103","volume":"17","author":[{"given":"Taylan","family":"Tugrul","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-13-20241021","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.meddos.2018.02.009","article-title":"Effects of heterogeneities in dose distributions under non-reference conditions: Monte Carlo simulation vs dose calculation algorithms","volume":"44","author":"Reis","year":"2019","journal-title":"Med Dosim"},{"key":"R2-13-20241021","first-page":"263","article-title":"A pencil beam model for photon dose calculation. Med","volume":"19","author":"Ahnesj\u00f6","year":"1992","journal-title":"Phys"},{"key":"R3-13-20241021","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.meddos.2013.02.005","article-title":"Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance","volume":"38","author":"Ali","year":"2013","journal-title":"Med Dosim"},{"key":"R5-13-20241021","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1088\/0031-9155\/39\/10\/007","article-title":"The dosimetric verification of a pencil beam-based treatment planning system","volume":"39","author":"Koons","year":"1994","journal-title":"Phys Med Biol"},{"key":"R6-13-20241021","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1088\/0031-9155\/50\/5\/010","article-title":"Monte Carlo-versus pencil-beam-\/collapsed-cone-dose calculation in a heterogeneous multi-layer phantom","volume":"50","author":"Krieger","year":"2005","journal-title":"Phys Med Biol"},{"key":"R7-13-20241021","doi-asserted-by":"crossref","first-page":"153","DOI":"10.3938\/jkps.67.153","article-title":"Comparison of pencil-beam, collapsed-cone, and monte-Carlo algorithms in radiotherapy treatment planning for 6-MV photons","volume":"67","author":"Kim","year":"2015","journal-title":"J Korean Phys Soc"},{"key":"R8-13-20241021","doi-asserted-by":"crossref","first-page":"1767","DOI":"10.1088\/0031-9155\/50\/8\/010","article-title":"A 3D photon superposition\/convolution algorithm and its foundation on results of Monte Carlo calculations","volume":"50","author":"Ulmer","year":"2005","journal-title":"Phys Med Biol"},{"key":"R9-13-20241021","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.radonc.2006.10.020","article-title":"Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning","volume":"81","author":"Bragg","year":"2006","journal-title":"Radiother Oncol"},{"key":"R10-13-20241021","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1088\/0031-9155\/52\/5\/011","article-title":"On the dosimetric behavior of photon dose calculation algorithms in the presence of simple geometric heterogeneities: Comparison with Monte Carlo calculations","volume":"52","author":"Fogliata","year":"2007","journal-title":"Phys Med Biol"},{"key":"R12-13-20241021","doi-asserted-by":"crossref","first-page":"3619","DOI":"10.1118\/1.3168966","article-title":"Variations of lung density and geometry on inhomogeneity correction algorithms: A Monte Carlo dosimetric evaluation","volume":"36","author":"Chow","year":"2009","journal-title":"Med Phys"},{"key":"R13-13-20241021","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1118\/1.596497","article-title":"The validity of the density scaling method in primary electron transport for photon and electron beams","volume":"17","author":"Woo","year":"1990","journal-title":"Med Phys"},{"key":"R14-13-20241021","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1118\/1.1861154","article-title":"Comparison of inhomogeneity correction algorithms in small photon fields","volume":"32","author":"Jones","year":"2005","journal-title":"Med Phys"},{"key":"R15-13-20241021","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1118\/1.596360","article-title":"Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media","volume":"16","author":"Agnes","year":"1989","journal-title":"Med Phys"},{"key":"R16-13-20241021","doi-asserted-by":"crossref","first-page":"2483","DOI":"10.1088\/0031-9155\/45\/9\/303","article-title":"Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system","volume":"45","author":"Ma","year":"2000","journal-title":"Phys Med Biol"},{"key":"R17-13-20241021","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1016\/j.ijrobp.2005.09.049","article-title":"Monte Carlo-based dosimetry of head-and-neck patients treated with SIB-IMRT","volume":"64","author":"Sakthi","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R18-13-20241021","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.rpor.2019.05.002","article-title":"Determination of initial electron parameters using Monte Carlo simulations for the siemens artiste linac 6 MV photon beam","volume":"24","author":"Tu\u011frul","year":"2019","journal-title":"Rep Pract Oncol Radiother"},{"key":"R19-13-20241021","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.radphyschem.2013.02.017","article-title":"Determining optimization of the initial parameters in Monte Carlo simulation for linear accelerator radiotherapy","volume":"95","author":"Chang","year":"2014","journal-title":"Radiat Phys Chem"},{"key":"R20-13-20241021","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.jksus.2016.03.003","article-title":"Validation of Monte Carlo Geant4 code for a 6 MV Varian linac","volume":"29","author":"Bakkali","year":"2017","journal-title":"J King Saud Univ Sci"},{"key":"R21-13-20241021","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1118\/1.3668315","article-title":"Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parameters","volume":"39","author":"Almberg","year":"2012","journal-title":"Med Phys"},{"key":"R22-13-20241021","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.ejmp.2016.11.104","article-title":"Dose calculation algorithm accuracy for small fields in non-homogeneous media: The lung SBRT case","volume":"44","author":"Fogliata","year":"2017","journal-title":"Phys Med"},{"key":"R23-13-20241021","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1118\/1.2815356","article-title":"Small fields: Nonequilibrium radiation dosimetry","volume":"35","author":"Das","year":"2008","journal-title":"Med Phys"},{"key":"R25-13-20241021","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1118\/1.596552","article-title":"Anthropomorphic radiation therapy phantoms: A quantitative assessment of tissue substitutes","volume":"17","author":"Kleck","year":"1990","journal-title":"Med Phys"},{"key":"R26-13-20241021","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.rpor.2018.11.004","article-title":"Dosimetric and Monte Carlo verification of jaws-only IMRT plans calculated by the collapsed cone convolution algorithm for head and neck cancers","volume":"24","author":"Tai","year":"2019","journal-title":"Rep Pract Oncol Radiother"},{"key":"R27-13-20241021","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1118\/1.597552","article-title":"BEAM: A Monte Carlo code to simulate radiotherapy treatment units","volume":"22","author":"Rogers","year":"1995","journal-title":"Med Phys"},{"key":"R29-13-20241021","doi-asserted-by":"crossref","first-page":"3666","DOI":"10.1118\/1.2336509","article-title":"Direct aperture optimization for IMRT using Monte Carlo generated beamlets","volume":"33","author":"Bergman","year":"2006","journal-title":"Med Phys"},{"key":"R31-13-20241021","first-page":"1","article-title":"Dosimetric evaluation of lung treatment plans produced by the Prowess Panther system using Monte Carlo simulation","volume":"5","author":"Oanh","year":"2019","journal-title":"Biomed. Phys. Eng. Express"},{"key":"R32-13-20241021","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/1742-6596\/102\/1\/012003","article-title":"A graphical user interface for calculation of 3D dose distribution using Monte Carlo simulations","volume":"102","author":"Chow","year":"2008","journal-title":"J Phys Conf Ser"},{"key":"R33-13-20241021","doi-asserted-by":"crossref","first-page":"255","DOI":"10.4329\/wjr.v8.i3.255","article-title":"Some computer graphical user interfaces inradiation therapy","volume":"8","author":"Chow","year":"2016","journal-title":"World J Radiol"},{"key":"R34-13-20241021","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.ejmp.2018.12.006","article-title":"Calculation of kQ factors for Farmer-type ionization chambers following the recent recommendations on new key dosimetry data","volume":"57","author":"Pimpinella","year":"2019","journal-title":"Phys Med"},{"key":"R36-13-20241021","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.radonc.2004.06.007","article-title":"Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations","volume":"73","author":"Nisbet","year":"2004","journal-title":"Radiother Oncol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.JCRT_1143_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:37:44Z","timestamp":1787067464000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.JCRT_1143_20"}},"subtitle":["The esophagus case"],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_1143_20","relation":{},"ISSN":["0973-1482"],"issn-type":[{"value":"0973-1482","type":"print"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}