{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:28:45Z","timestamp":1786649325427,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the effectiveness of the inverse planning simulated annealing (IPSA) and hybrid inverse planning optimization (HIPO) algorithms in interstitial HDR brachytherapy for treatment of cervical cancer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and Materials:<\/jats:title>\n                    <jats:p>A dosimetric study was conducted on 46 cervical cancer patients who underwent multi catheter interstitial cervical HDR brachytherapy using the Martinez Universal Perineal Interstitial Template (MUPIT). Dosimetric parameters, plan evaluation indices, and mean treatment time were assessed for each algorithm. All the parameters were compared using statistical analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      With HIPO, significant improvements were observed in D\n                      <jats:sub>90<\/jats:sub>\n                      , D\n                      <jats:sub>100<\/jats:sub>\n                      , V\n                      <jats:sub>100<\/jats:sub>\n                      , and V\n                      <jats:sub>200<\/jats:sub>\n                      (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). Additionally, HIPO plans demonstrated lower doses to the bladder (B\n                      <jats:sub>2cc<\/jats:sub>\n                      ) as compared to IPSA plans, whereas IPSA plans exhibited lower rectum (R\n                      <jats:sub>2cc<\/jats:sub>\n                      ) and sigmoid (S\n                      <jats:sub>2cc<\/jats:sub>\n                      ) doses, with statistical significance observed only for sigmoid doses. HIPO plans had better results in the plan evaluation indices such as CI, COIN, DHI, DNR, ODI, EI, NV\n                      <jats:sub>100<\/jats:sub>\n                      , GF\n                      <jats:sub>B<\/jats:sub>\n                      , GF\n                      <jats:sub>R<\/jats:sub>\n                      , GF, PQI\n                      <jats:sub>1<\/jats:sub>\n                      , PQI\n                      <jats:sub>2,<\/jats:sub>\n                      and PQS with statistical significance (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05) except for GF\n                      <jats:sub>S<\/jats:sub>\n                      . Moreover, HIPO plans had shorter mean treatment time compared to IPSA plans by 5.52 seconds, although this difference did not reach statistical significance. It was found that HIPO plans demonstrated superior dose-volumetric parameters for the high-risk clinical target volume (HR-CTV).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>In conclusion, HIPO emerged as the preferred algorithm for interstitial cervical HDR brachytherapy due to improved dose distribution in HR-CTV and plan quality as well.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_1335_24","type":"journal-article","created":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T11:00:12Z","timestamp":1751713212000},"page":"576-582","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A dosimetric study to evaluate the inverse planning simulated annealing (IPSA) and hybrid inverse planning optimization (HIPO) algorithms in HDR brachytherapy of cervical cancer"],"prefix":"10.4103","volume":"21","author":[{"given":"V Gogul","family":"Priean","sequence":"first","affiliation":[{"name":"Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lalit Mohan","family":"Aggarwal","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ankur","family":"Mourya","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy, State Cancer Institute, N.S.C.B Medical College, Jabalpur, Madhya Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunil","family":"Choudhary","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Syed M.","family":"Shajid","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Garud Cancer Hospital, Ahmednagar, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhijit","family":"Mandal","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ankita","family":"Singh","sequence":"additional","affiliation":[{"name":"Department Radiation Oncology, Kalyan Singh Super Speciality Cancer Institute, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,5]]},"reference":[{"key":"R1-20250707","doi-asserted-by":"crossref","first-page":"229","DOI":"10.3322\/caac.21834","article-title":"Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"74","author":"Bray","year":"2024","journal-title":"CA Cancer J Clin"},{"key":"R3-20250707","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1120\/jacmp.v11i3.3227","article-title":"Dosimetric comparison of various optimization techniques for high dose rate brachytherapy of interstitial cervix implants","volume":"11","author":"Shwetha","year":"2010","journal-title":"J Appl Clin Med Phys"},{"key":"R4-20250707","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1118\/1.1368127","article-title":"Inverse planning anatomy-based dose optimisation for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function","volume":"28","author":"Lessard","year":"2001","journal-title":"Med Phys"},{"key":"R5-20250707","doi-asserted-by":"crossref","first-page":"564580","DOI":"10.3389\/fonc.2020.564580","article-title":"An inverse dose optimisation algorithm for three-dimensional brachytherapy","volume":"10","author":"Wang","year":"2020","journal-title":"Front Oncol"},{"key":"R6-20250707","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1120\/jacmp.v14i4.4198","article-title":"Evaluation of hybrid inverse planning and optimisation (HIPO) algorithm for optimisation in real-time, high-dose-rate (HDR) brachytherapy for prostate","volume":"14","author":"Pokharel","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"R7-20250707","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1120\/jacmp.v15i6.5055","article-title":"Comparison of IPSA and HIPO inverse planning optimisation algorithms for prostate HDR brachytherapy","volume":"15","author":"Panettieri","year":"2014","journal-title":"J Appl Clin Med Phys"},{"key":"R8-20250707","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/acm2.13195","article-title":"Comparison of two inverse planning algorithms for cervical cancer brachytherapy","volume":"22","author":"Fu","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"R9-20250707","doi-asserted-by":"crossref","first-page":"e0205229","DOI":"10.1371\/journal.pone.0205229","article-title":"Comparison of the IPSA and HIPO algorithms for interstitial tongue high-dose-rate brachytherapy","volume":"13","author":"Choi","year":"2018","journal-title":"PLoS One"},{"key":"R10-20250707","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/j.jmir.2021.05.004","article-title":"Dose optimisation comparison study of inverse planning simulated annealing [IPSA] and hybrid inverse planning optimisation [HIPO] in interstitial brachytherapy of head and neck cancer","volume":"52","author":"Barik","year":"2021","journal-title":"J Med Imaging Radiat Sci"},{"key":"R11-20250707","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1007\/s00066-019-01513-x","article-title":"Dosimetric comparison of inverse optimisation methods versus forward optimisation in HDR brachytherapy of breast, cervical and prostate cancer","volume":"195","author":"Fr\u00f6hlich","year":"2019","journal-title":"Strahlenther Onkol"},{"key":"R12-20250707","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1002\/ijgo.12749","article-title":"Revised FIGO staging for carcinoma of the cervix uteri","volume":"145","author":"Bhatla","year":"2019","journal-title":"Int J Gynecol Obstet"},{"key":"R13-20250707","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.radonc.2021.05.010","article-title":"IBS-GEC ESTRO-ABS recommendations for CT based contouring in image guided adaptive brachytherapy for cervical cancer","volume":"160","author":"Mahantshetty","year":"2021","journal-title":"Radiother Oncol"},{"key":"R14-20250707","doi-asserted-by":"crossref","first-page":"201","DOI":"10.5114\/jcb.2016.60499","article-title":"Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements","volume":"8","author":"Poder","year":"2016","journal-title":"J Contemp Brachytherapy"},{"key":"R15-20250707","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s13246-014-0317-2","article-title":"The influence of the dwell time deviation constraint (DTDC) parameter on dosimetry with IPSA optimisation for HDR prostate brachytherapy","volume":"38","author":"Smith","year":"2015","journal-title":"Australas Phys Eng Sci Med"},{"key":"R16-20250707","doi-asserted-by":"crossref","first-page":"117","DOI":"10.5114\/jcb.2010.16923","article-title":"Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants","volume":"2","author":"Mavroidis","year":"2010","journal-title":"J Contemp Brachytherapy"},{"key":"R17-20250707","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.canrad.2022.10.006","article-title":"Plan quality score to evaluate the dwell time deviation restricted inverse planning by simulated annealing and graphically optimized treatment plans for template based interstitial brachytherapy","volume":"27","author":"Mondal","year":"2023","journal-title":"Cancer Radiother"},{"key":"R18-20250707","year":"2016","journal-title":"International Commission on Radiation Units and Measurements. Prescribing, recording, and reporting brachytherapy for cancer of the cervix (ICRU report 89). Bethesda"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1335_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:52:30Z","timestamp":1786647150000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1335_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_1335_24","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-07-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}