{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:28:50Z","timestamp":1786649330432,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>The aim of radiotherapy treatment is to deliver a high dose of radiation precisely to the target volume while minimizing exposure to the surrounding organs at risk. This approach maximizes the likelihood of tumor control and reduces the risk of adverse side effects. Treatment planning systems (TPS) are crucial in achieving this goal. However, the manual planning process is time-consuming, resource-intensive, and subject to variability based on the skill and experience of individual planners. Automated planning aims to reduce inter-plan variation and planning duration while maintaining or improving plan quality. Varian Medical Systems introduced the Ethos platform, an automated planning and delivery system utilizing an Intelligent Optimization Engine (IOE). This study evaluates the efficacy of automated plan generation using the Varian Ethos IOE for prostate cancer treatment, compared with plans generated using the Eclipse TPS with the anisotropic analytical algorithm (AAA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Fifteen retrospective patients diagnosed with prostate cancer, treated with a dose of 60 Gy in 20 fractions to the prostate, were included. Treatment approved Eclipse plans were recalculated and reoptimized with the same objective function, and then exported to the Ethos TPS. The Ethos TPS generates a total of five plans\u20147-, 9-, and 12-field IMRT plans, and 2- and 3-arc VMAT plans, respectively, maintaining fixed beam geometry. Two additional plans were also generated on Ethos: one maintaining identical parameters from Eclipse for calculation purposes, and a second involving re-optimization. The primary objective was to assess the number of prespecified dose constraints met, while the secondary objective was to compare dosimetric parameters, such as target coverage, dose conformity, dose homogeneity, and OAR sparing between the Ethos and Eclipse plans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>There was no statistically significant difference between the Eclipse plan and the Ethos-generated plans in meeting the prespecified criteria. For PTV coverage, mean values for V95 &gt; 95% were achieved across all plans. The mean values for V105 &lt; 5% were well below the threshold, indicating minimal hotspots. The conformity index (CI) was close to 1, and the homogeneity index (HI) was close to 0 across all plans, indicating good dose distribution and uniformity. OAR sparing for the urinary bladder, rectum, and penile bulb was within acceptable limits, meeting dose constraints in all plans. Monitor unit (MU) values were higher for Ethos plans compared to Eclipse but remained within clinically acceptable ranges.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The Ethos TPS, using its IOE, demonstrated the capability to generate high-quality radiotherapy plans for prostate cancer that are comparable to those produced by the Eclipse TPS. This suggests that the automated planning system can effectively reduce planning time and resource consumption while maintaining plan quality, thus supporting its potential clinical implementation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_1373_24","type":"journal-article","created":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T11:00:37Z","timestamp":1751713237000},"page":"593-601","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of the efficacy of automated machine learning enhanced planning system and a comparative analysis with manual planning system"],"prefix":"10.4103","volume":"21","author":[{"given":"Anand","family":"Jadhav","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology Sir H.N Reliance Foundation and Research Centre, Prarthana Samaj, Girgaon, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajinkya","family":"Gupte","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir H.N Reliance Foundation and Research Centre, Prarthana Samaj, Girgaon, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sachin","family":"Rasal","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir H.N Reliance Foundation and Research Centre, Prarthana Samaj, Girgaon, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omkar","family":"Awate","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir H.N Reliance Foundation and Research Centre, Prarthana Samaj, Girgaon, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prasad Raj","family":"Dandekar","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Sir H.N Reliance Foundation and Research Centre, Prarthana Samaj, Girgaon, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,5]]},"reference":[{"key":"R1-20250707","doi-asserted-by":"crossref","first-page":"229","DOI":"10.3322\/caac.21834","article-title":"Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"74","author":"Bray","year":"2024","journal-title":"CA Cancer J Clin"},{"key":"R2-20250707","doi-asserted-by":"crossref","first-page":"117","DOI":"10.3322\/canjclin.55.2.117","article-title":"Advances in radiation therapy: conventional to 3D, to IMRT, to 4D, and beyond","volume":"55","author":"Bucci","year":"2005","journal-title":"CA Cancer J Clin"},{"key":"R3-20250707","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.zemedi.2012.06.011","article-title":"Advances in 4D radiation therapy for managing respiration: Part II-4D treatment planning","volume":"22","author":"Rosu","year":"2012","journal-title":"Z Med Phys"},{"key":"R5-20250707","doi-asserted-by":"crossref","first-page":"8587","DOI":"10.1088\/1361-6560\/61\/24\/8587","article-title":"Development and clinical introduction of automated radiotherapy treatment planning for prostate cancer","volume":"61","author":"Winkel","year":"2016","journal-title":"Phys Med Biol"},{"key":"R6-20250707","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.prro.2011.11.012","article-title":"Variation in external beam treatment plan quality: An inter-institutional study of planners and planning systems","volume":"2","author":"Nelms","year":"2012","journal-title":"Pract Radiat Oncol"},{"key":"R7-20250707","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.semradonc.2011.09.005","article-title":"Quantitative metrics for assessing plan quality","volume":"22","author":"Moore","year":"2012","journal-title":"Semin Radiat Oncol"},{"key":"R8-20250707","doi-asserted-by":"crossref","first-page":"e99","DOI":"10.1016\/j.prro.2012.06.009","article-title":"How important is dosimetrist experience for intensity modulated radiation therapy? A comparative analysis of a head and neck case","volume":"3","author":"Batumalai","year":"2013","journal-title":"Pract Radiat Oncol"},{"key":"R9-20250707","doi-asserted-by":"crossref","first-page":"012055","DOI":"10.1088\/1742-6596\/489\/1\/012055","article-title":"Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning","volume":"489","author":"Moore","year":"2014","journal-title":"J Phys Conf Ser"},{"key":"R10-20250707","doi-asserted-by":"crossref","first-page":"100865","DOI":"10.1016\/j.adro.2021.100865","article-title":"Automated planning for prostate stereotactic body radiation therapy on the 1.5 T MR-Linac","volume":"7","author":"Naccarato","year":"2022","journal-title":"Adv Radiat Oncol"},{"key":"R11-20250707","doi-asserted-by":"crossref","first-page":"e83","DOI":"10.1016\/j.ijrobp.2010.12.007","article-title":"Improved planning time and plan quality through multicriteria optimization for intensity-modulated radiotherapy","volume":"82","author":"Craft","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R12-20250707","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/j.ijrobp.2018.05.063","article-title":"Automated instead of manual treatment planning? A plan comparison based on dose-volume statistics and clinical preference","volume":"102","author":"Vanderstraeten","year":"2018","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R13-20250707","doi-asserted-by":"crossref","first-page":"2760","DOI":"10.1002\/mp.13526","article-title":"Knowledge-based planning for intensity-modulated radiation therapy: A review of data-driven approaches","volume":"46","author":"Ge","year":"2019","journal-title":"Med Phys"},{"key":"R14-20250707","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.ijrobp.2016.10.005","article-title":"Highly Efficient training, refinement, and validation of a knowledge-based planning quality-control system for radiation therapy clinical trials","volume":"97","author":"Li","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R15-20250707","doi-asserted-by":"crossref","first-page":"100216","DOI":"10.1016\/j.tipsro.2023.100216","article-title":"Investigating the feasibility of using Ethos generated treatment plans for head and neck cancer patients","volume":"27","author":"El-qmache","year":"2023","journal-title":"Tech Innov Patient Support Radiat Oncol"},{"key":"R16-20250707","doi-asserted-by":"crossref","first-page":"e13539","DOI":"10.1002\/acm2.13539","article-title":"Assessment of efficacy in automated plan generation for Varian Ethos intelligent optimization engine","volume":"23","author":"Pokharel","year":"2022","journal-title":"J Appl Clin Med Phys"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1373_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:52:33Z","timestamp":1786647153000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1373_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":15,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_1373_24","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-07-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}