{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:32:51Z","timestamp":1787841171918,"version":"build-2784847793"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>A survey was conducted across various institutes to assess the footprints of patient-specific quality assurance (PSQA) in radiation oncology practice in India.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A multiple-choice pre-questionnaire was created to assess the practice of PSQA for intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). A Google Form was used to conduct the online survey. The medical physicists at different radiotherapy institutions with at least one functioning teletherapy machine received a Google Form via email\/social media with a link to a Google Form survey. The survey URL was shared with medical physicists with the understanding that participation would be voluntary.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The present survey turnout was 63.5% and the leading respondents were from tier II cities with 43.5%. The 41.7% hospital was treating more than 750 cancer patients every year. The majority of hospitals (99.0%) have C-series linear accelerators (LINAC). Most commonly used photon energy for treatment was 6 MV (FF\/FFF). The majority of users (94.44%) follow the gamma passing criteria of 3%\/3 mm, and 91.6% users follow the gamma passing rate of &gt;95%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The survey provided significant information on the current PSQA methods, instruments, and techniques used by different hospitals practicing IMRT and VMAT techniques. There was variation in the practice of PSQA, the equipment used, their methodology, and the analysis followed. The most common PSQA analysis followed was \u00b13% for ion chamber measurements and 3% dose difference and 3 mm distance to agreement for gamma-analysis. Additionally, limited use of a heterogeneous phantom for PSQA was observed in clinical settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_1674_25","type":"journal-article","created":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T13:06:37Z","timestamp":1774875997000},"page":"136-143","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Footprints of patient-specific quality assurance in radiation oncology in India: A survey"],"prefix":"10.4103","volume":"22","author":[{"given":"Ajay","family":"Katake","sequence":"first","affiliation":[{"name":"Department of Physics, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Phagwara, Punjab, India"},{"name":"Department of Radiation Oncology, N. M. Virani Wockhardt Hospital, Rajkot, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lalit","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Max Superspeciality Hospital, Saket, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepak","family":"Basandrai","sequence":"additional","affiliation":[{"name":"Department of Physics, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Phagwara, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,30]]},"reference":[{"key":"R1-20260331","first-page":"224","article-title":"Current approaches and novel treatment methods for cancer and radiotherapy","volume":"4","author":"Shirzadfar","year":"2018","journal-title":"Int J Biosens Bioelectron"},{"key":"R2-20260331","doi-asserted-by":"crossref","first-page":"193","DOI":"10.7150\/ijms.3635","article-title":"Cancer and radiation therapy: Current advances and future directions","volume":"9","author":"Baskar","year":"2012","journal-title":"Int J Med Sci"},{"issue":"Suppl 1","key":"R3-20260331","doi-asserted-by":"crossref","first-page":"S328","DOI":"10.4103\/jcrt.jcrt_879_21","article-title":"Radiobiological modeling of radiation-induced acute rectal mucositis: A single-institutional study of cervical carcinoma","volume":"19","author":"Singh","year":"2023","journal-title":"J Cancer Res Ther"},{"key":"R5-20260331","year":"1998","journal-title":"Quality Assurance in Radiotherapy. International Atomic Energy Agency"},{"key":"R7-20260331","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/S1470-2045(24)00678-8","article-title":"Global linear accelerator requirements and personalised country recommendations: A cross-sectional, population-based study","volume":"26","author":"Moraes","year":"2025","journal-title":"Lancet Oncol"},{"key":"R8-20260331","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1080\/0284186X.2020.1714721","article-title":"An IAEA survey of radiotherapy practice including quality assurance extent and depth","volume":"59","author":"Healy","year":"2020","journal-title":"Acta Oncol"},{"key":"R9-20260331","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1118\/1.2818738","article-title":"Volumetric modulated arc therapy: IMRT in a single gantryarc","volume":"35","author":"Otto","year":"2008","journal-title":"Med Phys"},{"key":"R10-20260331","article-title":"Specification and acceptance testing of radiotherapy treatment planning systems","author":"Vatnitsky","year":"2007","journal-title":"IAEA"},{"key":"R12-20260331","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1002\/mp.12810","article-title":"Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM task group no. 218","volume":"45","author":"Miften","year":"2018","journal-title":"Med Phys"},{"key":"R13-20260331","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1002\/acm2.13294","article-title":"Survey of patient-specific quality assurance practice for IMRT and VMAT","volume":"22","author":"Chan","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"R14-20260331","article-title":"Guidelines for the verification of IMRT","author":"Alber","year":"2008","journal-title":"ESTRO booklet"},{"key":"R15-20260331","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1118\/1.3514120","article-title":"Dosimetry tools and techniques for IMRT","volume":"38","author":"Low","year":"2011","journal-title":"Med Phys"},{"key":"R16-20260331","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1186\/s13014-019-1273-5","article-title":"National survey of patient specific IMRT quality assurance in China","volume":"14","author":"Pan","year":"2019","journal-title":"Radiat Oncol"},{"key":"R17-20260331","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1002\/acm2.12885","article-title":"Survey results of 3D-CRT and IMRT quality assurance practice","volume":"21","author":"Mehrens","year":"2020","journal-title":"J Appl Clin Med Phys"},{"key":"R18-20260331","doi-asserted-by":"crossref","first-page":"e28","DOI":"10.1016\/j.clon.2016.01.013","article-title":"Changes in patterns of Intensity-modulated radiotherapy verification and quality assurance in the UK","volume":"28","author":"Abolaban","year":"2016","journal-title":"Clin Oncol (R Coll Radiol)"},{"key":"R19-20260331","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.zemedi.2023.02.003","article-title":"Reduction of patient specific quality assurance through plan complexity metrics for VMAT plans with an open-source TPS script","volume":"34","author":"Uher","year":"2024","journal-title":"Z Med Phys"},{"key":"R20-20260331","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.ijrobp.2022.04.040","article-title":"Prospective clinical validation of virtual patient-specific quality assurance of volumetric modulated arc therapy radiation therapy plans","volume":"113","author":"Wall","year":"2022","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R21-20260331","doi-asserted-by":"crossref","first-page":"7221","DOI":"10.1088\/0031-9155\/61\/19\/7221","article-title":"The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy","volume":"61","author":"Mans","year":"2016","journal-title":"Phys Med Biol"},{"key":"R22-20260331","article-title":"National audit of Quality Assurance for Intensity Modulated Radiotherapy and Volumetric Modulated Arc Therapy","author":"Seravalli","year":"2018","journal-title":"Netherlands Commission on Radiation Dosimetry (NCS)"},{"key":"R23-20260331","first-page":"66","article-title":"IPEM topical report: Results of a 2020 UK survey on the use of online treatment monitoring solutions for IMRT\/VMAT","author":"W","year":"2021","journal-title":"Phys Med Biol"},{"key":"R24-20260331","first-page":"68","article-title":"IPEM topical report: Guidance for the clinical implementation of online treatment monitoring solutions for IMRT\/VMAT","author":"Stevens","year":"2023","journal-title":"Phys Med Biol"},{"key":"R25-20260331","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.1118\/1.3117563","article-title":"Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy","volume":"36","author":"Letourneau","year":"2009","journal-title":"Med Phys"},{"key":"R26-20260331","doi-asserted-by":"crossref","first-page":"3346","DOI":"10.1120\/jacmp.v12i2.3346","article-title":"Evaluation of a new VMAT QA device, or the \u201cX\u201d and \u201cO\u201d array geometries","volume":"12","author":"Feygelman","year":"2011","journal-title":"J Appl Clin Med Phys"},{"key":"R27-20260331","doi-asserted-by":"crossref","first-page":"3050","DOI":"10.1016\/j.matpr.2020.10.899","article-title":"Design and fabrication of a thoracic phantom for radiation dose verification in mega-voltage X-ray beam","volume":"49","author":"Kumar","year":"2022","journal-title":"Mater Today Proc"},{"key":"R28-20260331","doi-asserted-by":"crossref","first-page":"108638","DOI":"10.1016\/j.radphyschem.2019.108638","article-title":"A study for the development of a low-density heterogeneous phantom for dose verification in high energy photon beam","volume":"170","author":"Kishore","year":"2020","journal-title":"Radiat Phys Chem"},{"key":"R29-20260331","first-page":"44","article-title":"Radiation dose verification using real tissue phantom in modern radiotherapy techniques","volume":"39","author":"Gurjar","year":"2014","journal-title":"J Med Physics\/Association Med Phys India"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1674_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:45:00Z","timestamp":1787838300000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_1674_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_1674_25","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"2025-08-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}