{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:25:20Z","timestamp":1787775920600,"version":"build-2784847793"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>This study aimed to determine the correlation between bladder volume changes and set-up accuracy in cervical cancer patients undergoing radiotherapy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Forty patients who underwent intensity-modulated radiotherapy were divided into two groups based on their position during treatment: group A (supine) and group B (prone). Correlations between bladder volume changes and set-up accuracy were retrospectively analyzed using archived data and image files.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The rate of bladder volume change in group A (\u20133.99% [\u201324.51\u201331.53]) was significantly higher (Z = \u20132.724;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.006) than that in group B (\u201314.95% [\u201341.63\u20137.64]). The set-up errors in the X (left-right), Y (cranial-caudal), and Z (anterior-posterior) directions were 0.05 \u00b1 2.25 mm, 0.84 \u00b1 2.63 mm, and 0.41 \u00b1 2.35 mm, respectively, in group A and \u20130.31 \u00b1 2.22 mm, \u20130.38 \u00b1 2.88 mm, and 0.78 \u00b1 3.41 mm, respectively, in group B. No significant differences in the X and Z directions were detected between the two groups; however, a significant difference was detected in the Y direction. The set-up error in the X direction was positively correlated with the rate of bladder volume change (r = 0.284;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.010) in group A; no correlations were observed in the X, Y, and Z directions in group B.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Patients in the prone position demonstrated better performance in the Y direction than those in the supine position. The set-up error in the X direction was positively correlated with the rate of bladder volume change among patients in the supine position.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_2050_24","type":"journal-article","created":{"date-parts":[[2025,5,3]],"date-time":"2025-05-03T02:04:23Z","timestamp":1746237863000},"page":"401-408","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Supine\/prone position fixation treatment in cervical cancer radiotherapy"],"prefix":"10.4103","volume":"21","author":[{"given":"Zhiman","family":"Zheng","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongyue","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Binhaiwan Central Hospital of Dongguan, Dongguan, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yangmei","family":"Su","sequence":"additional","affiliation":[{"name":"Department of Neuro-oncology, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,5,2]]},"reference":[{"key":"R1-20250512","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.4103\/jcrt.jcrt_1021_21","article-title":"Correlation of menstrual hygiene management with cervical intraepithelial neoplasia and cervical cancer","volume":"19","author":"Singh","year":"2023","journal-title":"J Cancer Res Ther"},{"key":"R2-20250512","doi-asserted-by":"crossref","first-page":"273","DOI":"10.4103\/jcrt.JCRT_9_20","article-title":"Isolated humeral metastasis in cervical cancer: A case report and review of the literature","volume":"18","author":"Gioe","year":"2022","journal-title":"J Cancer Res Ther"},{"key":"R3-20250512","first-page":"3356431","article-title":"Epidemiological trends and attributable risk burden of cervical cancer: An observational study from 1990 to 2019","author":"Yao","year":"2022","journal-title":"Int J Clin Pract 2022"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/1748-717X-5-63","article-title":"Intensity-modulated radiotherapy in patients with cervical cancer. An intra-individual comparison of prone and supine positioning","volume":"5","author":"Stromberger","year":"2010","journal-title":"Radiat Oncol"},{"key":"R5-20250512","first-page":"17","article-title":"Short course irradiation in rectal cancer: Dosimetry study comparing 3D conformal radiotherapy versus intensity-modulated radiotherapy versus volumetric modulated arc therapy","author":"Algaoud","year":"2024","journal-title":"J Radiat Res Appl Sci"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.canrad.2021.08.002","article-title":"Image-guided radiotherapy","volume":"26","author":"de Crevoisier","year":"2022","journal-title":"Cancer Radiother"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1111\/jgs.13479","article-title":"Clinical meaning of a high postvoid residual: When the value of a result is less and more than one would expect","volume":"63","author":"Smith","year":"2015","journal-title":"J Am Geriatr Soc"},{"key":"R8-20250512","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1111\/luts.12161","article-title":"Radiation exposure during videourodynamics: Establishing risk factors","volume":"10","author":"Brucker","year":"2018","journal-title":"Low Urin Tract Symptoms"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.4103\/jcrt.jcrt_2353_21","article-title":"The effect of lower urinary tract substructure doses on side effects of cervical cancer image-guided adaptive brachytherapy","volume":"19","author":"Azak","year":"2023","journal-title":"J Cancer Res Ther"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1097\/IGC.0000000000001312","article-title":"the effect of body mass index and weight change on late gastrointestinal toxicity in locally advanced cervical cancer treated with intensity-modulated radiotherapy","volume":"28","author":"Lee","year":"2018","journal-title":"Int J Gynecol Cancer"},{"key":"R11-20250512","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.3802\/jgo.2024.35.e4","article-title":"Predictive factors of surgical complications after pelvic exenteration for gynecological malignancies: A large single-institution experience","volume":"35","author":"Tortorella","year":"2024","journal-title":"J Gynecol Oncol"},{"key":"R12-20250512","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/S0167-8140(03)00244-5","article-title":"Dose-volume histogram evaluation of prone and supine patient position in external beam radiotherapy for cervical and endometrial cancer","volume":"69","author":"Pinkawa","year":"2003","journal-title":"Radiother Oncol"},{"key":"R13-20250512","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1177\/1533034617709596","article-title":"Transabdominal ultrasonography-defined optimal and definitive bladder-filling protocol with time trends during pelvic radiation for cervical cancer","volume":"16","author":"Umesh","year":"2017","journal-title":"Technol Cancer Res Treat"},{"key":"R14-20250512","doi-asserted-by":"crossref","first-page":"170","DOI":"10.4103\/jcrt.JCRT_313_19","article-title":"Dose-volume analysis of acute gastrointestinal complications in cervical cancer undergoing definitive concurrent chemoradiation","volume":"17","author":"Kumar","year":"2021","journal-title":"J Cancer Res Ther"},{"key":"R15-20250512","doi-asserted-by":"crossref","first-page":"569.e1","DOI":"10.1016\/j.jpurol.2018.07.018","article-title":"SENS-U: Validation of a wearable ultrasonic bladder monitor in children during urodynamic studies","volume":"14","author":"van","year":"2018","journal-title":"J Pediatr Urol"},{"key":"R16-20250512","first-page":"6","article-title":"Bladder filling test, cystoscopy, or both for checking bladder perforation in tension-free-vaginal tape operations","author":"Kalkan","year":"2024","journal-title":"J Surg Med"},{"key":"R17-20250512","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.meddos.2017.12.005","article-title":"Offline adaptive radiation therapy in the treatment of prostate cancer: A case study","volume":"44","author":"Nigay","year":"2019","journal-title":"Med Dosim"},{"key":"R18-20250512","first-page":"975","article-title":"Influence of the change of bladder volume on the radiotherapy of cervical cancer","volume":"2014","author":"Liu","journal-title":"J Med Res"},{"key":"R19-20250512","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1053\/j.semradonc.2003.10.003","article-title":"Errors and margins in radiotherapy","volume":"14","author":"van Herk","year":"2004","journal-title":"Semin Radiat Oncol"},{"key":"R20-20250512","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.ijrobp.2009.06.039","article-title":"Biological in situ dose painting for image-guided radiation therapy using drug-loaded implantable devices","volume":"76","author":"Cormack","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R21-20250512","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1007\/s00411-023-01040-5","article-title":"Recall of residential history and dietary habits during pregnancy and lactation in the distant past: Reliability of questionnaire-based radiation doses for persons exposed in utero and early life","volume":"62","author":"Drozdovitch","year":"2023","journal-title":"Radiat Environ Biophys"},{"key":"R22-20250512","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.ijrobp.2014.05.039","article-title":"Dosimetrically triggered adaptive intensity modulated radiation therapy for cervical cancer","volume":"90","author":"Lim","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R23-20250512","first-page":"94","article-title":"Effects of bladder status on cervical cancer treatment withintensity-modulated radiation therapy plans","volume":"1","author":"Ye","year":"2017","journal-title":"Chin J Can Prev Treat"},{"key":"R24-20250512","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/S0167-8140(01)00471-6","article-title":"The impact of patient positioning on the adequate coverage of the uterus in the primary irradiation of cervical carcinoma: A prospective analysis using magnetic resonance imaging","volume":"63","author":"Weiss","year":"2002","journal-title":"Radiother Oncol"},{"key":"R25-20250512","first-page":"4","article-title":"Consistency of bladder filling during intensity-modulated radiotherapy for cervical cancer","volume":"27","author":"Lu","year":"2018","journal-title":"Chin J Radiat Oncol"},{"key":"R26-20250512","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1093\/jrr\/rrac065","article-title":"Planning study: Prone versus supine position for stereotactic body radiotherapy in prostate by CyberKnife","volume":"64","author":"Kon","year":"2023","journal-title":"J Radiat Res"},{"key":"R27-20250512","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1186\/s13014-023-02285-6","article-title":"Advantages and robustness of partial VMAT with prone position for neoadjuvant rectal cancer evaluated by CBCT-based offline adaptive radiotherapy","volume":"18","author":"Zhang","year":"2023","journal-title":"Radiat Oncol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_2050_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:44:59Z","timestamp":1787773499000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_2050_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_2050_24","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"2024-10-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-20","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}