{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T01:08:28Z","timestamp":1791421708144,"version":"4.3.3"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>In this study, efficacy of collapsed cone algorithm-generated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) were evaluated for treatment of thoracic esophageal cancer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Ten previously treated patients with VMAT were considered for evaluation. The planning parameters were evaluated in terms of max dose, mean dose, Homogeneity Index, Conformity Index for planning target volume, and organ at risk doses. Total monitor unit, treatment time, and gamma passing index were also reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The target dose coverage of the VMAT and IMRT plans achieved the clinical dosimetric criteria for all ten patients in the evaluation. Under the condition of equivalent target dose distribution, the VMAT plan\u2019s Conformity Index, monitor unit, treatment time, and gamma passing index rate were superior than in the IMRT plan, and the result was statistically significant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Collapsed cone algorithm-based VMAT can have a more effective and better approach for esophageal cancer than IMRT<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_2171_22","type":"journal-article","created":{"date-parts":[[2024,3,30]],"date-time":"2024-03-30T15:02:13Z","timestamp":1711810933000},"page":"383-388","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Efficacy of the collapsed cone algorithm calculated radiotherapy plans in intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT): A comparative dosimetric study in tumors of thorax"],"prefix":"10.4103","volume":"20","author":[{"given":"Atul","family":"Mishra","sequence":"first","affiliation":[{"name":"Department of Physics, Tilak Dhari P. G. College, Jaunpur, Uttar Pradesh, India"},{"name":"Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India"},{"name":"Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramji","family":"Pathak","sequence":"additional","affiliation":[{"name":"Department of Physics, Tilak Dhari P. G. College, Jaunpur, Uttar Pradesh, India"},{"name":"Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India"},{"name":"Department of Physics, D.A.V. Degree College, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kailash Kumar","family":"Mittal","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anoop Kumar","family":"Srivastava","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maurya Surendrakumar","family":"Dayashankar","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, Amity University Gwalior, Madhya Pradesh, India"},{"name":"Department of Radiation Oncology, Shalby Hospitals Indore, Madhya Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Surendra Prasad","family":"Mishra","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudesh Kumar","family":"Singh","sequence":"additional","affiliation":[{"name":"Department of Physics, Tilak Dhari P. G. College, Jaunpur, Uttar Pradesh, India"},{"name":"Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,3,29]]},"reference":[{"key":"R1-20260507","doi-asserted-by":"crossref","first-page":"2706.","DOI":"10.3390\/cancers14112706","article-title":"Radiation therapy in thoracic tumors: Recent trends and current issues","volume":"14","author":"Cella","year":"2022","journal-title":"Cancers"},{"key":"R2-20260507","first-page":"S6","article-title":"Principles of modern radiation techniques for esophageal and gastroesophageal junction cancers","volume":"3","author":"Yang","year":"2009","journal-title":"Gastrointest Cancer Res"},{"key":"R3-20260507","doi-asserted-by":"crossref","first-page":"41.","DOI":"10.1186\/1471-2407-11-41","article-title":"Phase II study evaluating consolidation whole abdominal intensity-modulated radiotherapy (IMRT) in patients with advanced ovarian cancer stage FIGO III - The OVAR-IMRT-02 study","volume":"11","author":"Rochet","year":"2011","journal-title":"BMC Cancer"},{"key":"R4-20260507","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1016\/j.ijrobp.2009.09.067","article-title":"Intensity-modulated radiotherapy for sinonasal cancer: Improved outcome compared to conventional radiotherapy","volume":"78","author":"Dirix","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R5-20260507","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.critrevonc.2009.03.003","article-title":"Radiobiological basis and clinical results of the simultaneous integrated boost (SIB) in intensity modulated radiotherapy (IMRT) for head and neck cancer: A review","volume":"73","author":"Orlandi","year":"2010","journal-title":"Crit Rev Oncol Hematol"},{"key":"R6-20260507","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/j.clon.2010.06.013","article-title":"Radiotherapy Development Board. A review of the clinical evidence for intensity-modulated radiotherapy","volume":"22","author":"Staffurth","year":"2010","journal-title":"Clin Oncol (R Coll Radiol)"},{"key":"R7-20260507","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.ijrobp.2010.09.058","article-title":"Late toxicity after intensity-modulated radiation therapy for localized prostate cancer: An exploration of dose-volume histogram parameters to limit genitourinary and gastrointestinal toxicity","volume":"82","author":"Pederson","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R8-20260507","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1259\/bjr\/19152959","article-title":"Quality assurance of dynamic parameters in volumetric modulated arc therapy","volume":"85","author":"Manikandan","year":"2012","journal-title":"Br J Radiol"},{"key":"R9-20260507","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.ijrobp.2018.01.098","article-title":"Electromagnetic-guided MLC tracking radiation therapy for prostate cancer patients: Prospective clinical trial results","volume":"101","author":"Keall","year":"2018","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R10-20260507","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.radonc.2009.08.011","article-title":"Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer","volume":"93","author":"Wolff","year":"2009","journal-title":"Radiother Oncol"},{"key":"R11-20260507","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.radonc.2009.10.002","article-title":"Radiotherapy of malignant gliomas: Comparison of volumetric single arc technique (RapidArc), dynamic intensity-modulated technique and 3D conformal technique","volume":"93","author":"Wagner","year":"2009","journal-title":"Radiother Oncol"},{"key":"R12-20260507","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/j.ijrobp.2015.03.030","article-title":"Expert consensus contouring guidelines for intensity modulated radiation therapy in esophageal and gastroesophageal junction cancer","volume":"92","author":"Wu","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R13-20260507","doi-asserted-by":"crossref","first-page":"4460.","DOI":"10.1120\/jacmp.v14i6.4460","article-title":"A critical evaluation of the PTW 2D-ARRAY seven29 and OCTAVIUS II phantom for IMRT and VMAT verification","volume":"14","author":"Hussein","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"R14-20260507","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1002\/mp.12810","article-title":"Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218","volume":"45","author":"Miften","year":"2018","journal-title":"Med Phys"},{"issue":"021","key":"R15-20260507","first-page":"01836","article-title":"Dosimetric assessment of IMRT treatment planning for unilateral breast cancer patient using Octavius phantom detector","volume":"s13204","author":"Alwakeel","year":"2021","journal-title":"Appl Nanosci"},{"key":"R16-20260507","doi-asserted-by":"crossref","first-page":"871","DOI":"10.4103\/0973-1482.138217","article-title":"Dosimetric comparison between volumetric modulated arc therapy (VMAT) vs intensity modulated radiation therapy (IMRT) for radiotherapy of mid esophageal carcinoma","volume":"10","author":"Kataria","year":"2014","journal-title":"J Can Res Ther"},{"key":"R17-20260507","doi-asserted-by":"crossref","first-page":"372.","DOI":"10.1097\/MD.0000000000000372","article-title":"Dosimetric comparative study of 3 different postoperative radiotherapy techniques (3D-CRT, IMRT, and RapidArc) for II-III stage rectal cancer","volume":"94","author":"Liu","year":"2015","journal-title":"Medicine"},{"issue":"37","key":"R18-20260507","first-page":"5266","article-title":"Volumetric-modulated arc therapy vs c-IMRT in esophageal cancer: A treatment planning comparison","volume":"18","author":"Yin","year":"2012","journal-title":"World Journal of Gastroenterology"},{"key":"R19-20260507","doi-asserted-by":"crossref","first-page":"211","DOI":"10.7785\/tcrt.2012.500289","article-title":"Single arc volumetric modulated arc therapy for complex brain gliomas: Is there an advantage as compared to intensity modulated radiotherapy or by adding a partial arc?","author":"Davidson","year":"2012","journal-title":"Technol Cancer Res Treat"},{"key":"R20-20260507","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1118\/1.3326965","article-title":"Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: Plan quality, delivery efficiency and accuracy","volume":"37","author":"Rao","year":"2010","journal-title":"Med Phys"},{"key":"R21-20260507","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1259\/bjr\/22373346","article-title":"Volumetric modulated arc therapy: A review of current literature and clinical use in practice","volume":"84","author":"Teoh","year":"2011","journal-title":"Br J Radiol"},{"key":"R22-20260507","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.meddos.2010.09.009","article-title":"Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer","volume":"36","author":"Van Benthuysen","year":"2011","journal-title":"Med Dosim"},{"issue":"3","key":"R23-20260507","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.meddos.2017.09.001","article-title":"Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy","volume":"43","author":"Chen","year":"2018","journal-title":"Med Dosim"},{"key":"R24-20260507","doi-asserted-by":"crossref","first-page":"e750.","DOI":"10.1097\/MD.0000000000000750","article-title":"Comparing treatment plan in all locations of esophageal cancer: Volumetric modulated arc therapy versus intensity-modulated radiotherapy","volume":"94","author":"Lin","year":"2015","journal-title":"Medicine (Baltimore)"},{"key":"R25-20260507","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.radonc.2011.08.030","article-title":"Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT and Arc technique for esophageal carcinoma","volume":"101","author":"Martin","year":"2011","journal-title":"Radiother Oncol"},{"key":"R26-20260507","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.ijrobp.2007.10.056","article-title":"Risk factors for pericardial effusion in inoperable esophageal cancer patients treated with definitive chemoradiation therapy","volume":"70","author":"Wei","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R27-20260507","article-title":"Study on esophageal cancer radiotherapy dosimetry and position verification for volumetric modulated arc therapy","author":"Guo","year":"2022","journal-title":"Asian J Surg"},{"key":"R28-20260507","doi-asserted-by":"crossref","first-page":"5359","DOI":"10.1118\/1.3238104","article-title":"IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119","volume":"36","author":"Ezzell","year":"2009","journal-title":"Med Phys"},{"key":"R29-20260507","first-page":"452","article-title":"Beam modeling in commercial treatment planning system for IMRT and VMAT performance with an Elekta MLCI 2 multileaf collimator","volume":"18","author":"Raoui","year":"2021","journal-title":"Iran J Med Phys"},{"key":"R30-20260507","first-page":"e30885.","article-title":"Gamma index analysis as a patient-specific quality assurance tool for high-precision radiotherapy: A clinical perspective of single institute experience","volume":"14","author":"Das","year":"2022","journal-title":"Cureus"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_2171_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T16:26:41Z","timestamp":1786724801000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_2171_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_2171_22","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"2022-10-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}