{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:34:51Z","timestamp":1787070891700,"version":"build-2736575974"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>The diagnosis accuracy of computed tomography (CT) systems and the reliability of calculated Hounsfield Units (HUs) are critical in tumor detection and cancer patients\u2019 treatment planning. This study evaluated the effects of scan parameters (Kilovoltage peak or kVp, milli-Ampere-second or mAS reconstruction kernels and algorithms, reconstruction field of view, and slice thickness) on image quality, HUs, and the calculated dose in the treatment planning system (TPS).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A quality dose verification phantom was scanned several times by a 16-slice Siemens CT scanner. The DOSIsoft ISO gray TPS was applied for dose calculations. The SPSS.24 software was used to analyze the results and the P-value &lt;0.05 was considered significant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Reconstruction kernels and algorithms significantly affected noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The noise increased and CNR decreased by raising the sharpness of reconstruction kernels. SNR and CNR had considerable increments at iterative reconstruction compared with the filtered back-projection algorithm. The noise decreased by raising mAS in soft tissues. Also, KVp had a significant effect on HUs. TPS--calculated dose variations were less than 2% for mediastinum and backbone and less than 8% for rib.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Although HU variation depends on image acquisition parameters across a clinically feasible range, its dosimetric impact on the calculated dose in TPS can be neglected. Hence, it can be concluded that the optimized values of scan parameters can be applied to obtain the maximum diagnostic accuracy and calculate HUs more precisely without affecting the calculated dose in the treatment planning of cancer patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_260_21","type":"journal-article","created":{"date-parts":[[2023,6,13]],"date-time":"2023-06-13T01:12:07Z","timestamp":1686618727000},"page":"426-434","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":14,"title":["Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: A semi-anthropomorphic thorax phantom study"],"prefix":"10.4103","volume":"19","author":[{"given":"Elahe","family":"Sorooshfard","sequence":"first","affiliation":[{"name":"Department of Medical Physics, Medicine Faculty, Ahvaz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marziyeh","family":"Tahmasbi","sequence":"additional","affiliation":[{"name":"Department of Radiology Technology, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nahid","family":"Chegeni","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Medicine Faculty, Ahvaz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad Javad Tahmasebi","family":"Birgani","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Medicine Faculty, Ahvaz, Iran"},{"name":"Department of Radiation Oncology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,3,16]]},"reference":[{"key":"R1-20241021","first-page":"475","article-title":"Accurateassessment and prediction of noise in clinical CT images","volume":"43","author":"Tian","year":"2016","journal-title":"MedPhys"},{"key":"R2-20241021","doi-asserted-by":"crossref","first-page":"213","DOI":"10.2967\/jnmt.106.037846","article-title":"Principles of CT:Radiation dose and image quality","volume":"35","author":"Goldman","year":"2007","journal-title":"JNucl Med Technol"},{"key":"R3-20241021","first-page":"25","article-title":"Effects of different reconstruction kernels on noise and spatial resolution of computed tomography images:A phantom study","volume":"11","author":"Khorramian","year":"2016","journal-title":"Paramed Sci Mil Health"},{"key":"R5-20241021","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1148\/radiol.2015132766","article-title":"State of the art:iterative CT reconstruction techniques","volume":"276","author":"Geyer","year":"2015","journal-title":"Radiology"},{"key":"R6-20241021","first-page":"255","article-title":"Effects of image distortion and Hounsfield unit variations on radiation treatment plans:An extended field-of-view reconstruction in a large bore CT scanner","volume":"10","author":"Bae","year":"2020","journal-title":"SciRep"},{"key":"R7-20241021","first-page":"255","article-title":"An assessment of image distortion and CT number accuracy within a wide-bore CT extended field of view","volume":"38","author":"Beeksma","year":"2015","journal-title":"AustralaPhysEngSciMed"},{"key":"R8-20241021","first-page":"335","article-title":"Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy","volume":"48","author":"Cozzi","year":"1998","journal-title":"RadiotherOncol"},{"key":"R9-20241021","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.ejmp.2017.11.036","article-title":"Assessment of the variation in CT scanner performance (image quality and Hounsfield units) with scan parameters, for image optimisation in radiotherapy treatment planning","volume":"45","author":"Davis","year":"2018","journal-title":"Phys Med"},{"key":"R10-20241021","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.ejmp.2020.09.003","article-title":"Can different Catphan phantoms be used in a multi-centre audit of radiotherapy CT image quality?","volume":"78","author":"Davis","year":"2020","journal-title":"Phys Med"},{"key":"R11-20241021","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.ejro.2018.02.002","article-title":"Image quality with iterative reconstruction techniques in CT of the lungs-A phantom study","volume":"5","author":"Andersen","year":"2018","journal-title":"Eur J Radiol Open"},{"key":"R12-20241021","doi-asserted-by":"crossref","first-page":"442","DOI":"10.5152\/dir.2019.18539","article-title":"Effect of iterative reconstruction techniques on image quality in low radiation dose chest CT:A phantom study","volume":"25","author":"Xu","year":"2019","journal-title":"Diagn Interv Radiol"},{"key":"R13-20241021","first-page":"198","article-title":"The impact of dental metal artifacts on head and neck IMRT dose distributions","volume":"79","author":"Kim","year":"2006","journal-title":"RadiotherOncol"},{"key":"R14-20241021","doi-asserted-by":"crossref","first-page":"N329","DOI":"10.1088\/0031-9155\/54\/15\/N01","article-title":"Cone beam computerized tomography:The effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy","volume":"54","author":"Hatton","year":"2009","journal-title":"Phys Med Biol"},{"key":"R15-20241021","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/S0167-8140(00)00159-6","article-title":"Applications of simulator computed tomography number for photon dose calculations during radiotherapy treatment planning","volume":"55","author":"Chu","year":"2000","journal-title":"Radiother Oncol"},{"key":"R16-20241021","first-page":"112","article-title":"Assessment of CT Imaging protocols impacts on calculation of point dose in water phantom using radiotherapy treatment planning system","volume":"7","author":"Mohammadi","year":"2020","journal-title":"Frontiers in Biomedical Technologies"},{"key":"R17-20241021","first-page":"16","article-title":"Evaluating the impact of CT scanning parameters on dose calculations by the treatment planning system in external beam radiation therapy","volume":"1","author":"Brevitt","year":"2020","journal-title":"J Can Ther Res"},{"key":"R18-20241021","first-page":"477","article-title":"Dose reduction with iterative reconstruction:Optimization of CT protocols in clinical practice","volume":"96","author":"Greffier","year":"2015","journal-title":"DiagnInterv Imaging"},{"key":"R19-20241021","first-page":"237","article-title":"Acceptance testing computerized radiation therapy treatment planning systems:Direct utilization of CT scan data","volume":"12","author":"McCullough","year":"1985","journal-title":"MedPhys"},{"key":"R20-20241021","doi-asserted-by":"crossref","first-page":"903","DOI":"10.3109\/02841851.2010.504740","article-title":"Impact on image quality and radiation exposure in coronary CT angiography:100 kVp versus 120 kVp","volume":"51","author":"Ripsweden","year":"2010","journal-title":"Acta Radiol"},{"key":"R21-20241021","article-title":"Effect of low tube voltage on image quality, radiation dose, and low-contrast detectability at abdominal multidetector CT:Phantom study","volume":"2012","author":"Tang","year":"2012","journal-title":"BioMed Res Int"},{"key":"R22-20241021","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.radi.2017.03.013","article-title":"Impact of CT parameters on the physical quantities related to image quality for two MDCT scanners using the ACR accreditation phantom:A phantom study","volume":"23","author":"Alikhani","year":"2017","journal-title":"Radiography"},{"key":"R23-20241021","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1148\/radiol.2373041643","article-title":"Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low\u2013tube voltage technique:Phantom study","volume":"237","author":"Funama","year":"2005","journal-title":"Radiology"},{"key":"R24-20241021","first-page":"102","article-title":"Variation of noise with some scanning parameters for image quality test in A 128 slice computed tomography scanner using Catphan700 phantom","volume":"1","author":"Manson","year":"2018","journal-title":"J Radiol Diagn Methods"},{"key":"R25-20241021","doi-asserted-by":"crossref","first-page":"592","DOI":"10.2214\/AJR.12.8580","article-title":"Relating noise to image quality indicators in CT examinations with tube current modulation","volume":"200","author":"Solomon","year":"2013","journal-title":"Am J Roentgenol"},{"key":"R26-20241021","first-page":"1431","article-title":"Sinogram affirmed iterative reconstruction in head CT:Improvement of objective and subjective image quality with concomitant radiation dose reduction","volume":"82","author":"Korn","year":"2013","journal-title":"EurJRadiol"},{"key":"R27-20241021","first-page":"533","article-title":"Comparison of image quality between conventional and low-dose nonenhanced head CT","volume":"25","author":"Mullins","year":"2004","journal-title":"Am J Neuroradiol"},{"key":"R28-20241021","first-page":"20160406","article-title":"Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose?A systematic review","volume":"90","author":"Davis","year":"2017","journal-title":"BrJRadiol"},{"key":"R29-20241021","doi-asserted-by":"crossref","first-page":"1444","DOI":"10.1118\/1.3549757","article-title":"Noise-resolution tradeoffs in x-ray CT imaging:A comparison of penalized alternating minimization and filtered backprojection algorithms","volume":"38","author":"Evans","year":"2011","journal-title":"Med Phys"},{"key":"R30-20241021","first-page":"e699","article-title":"Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner:Study with an anthropomorphic and water phantom","volume":"81","author":"Paul","year":"2012","journal-title":"EurJRadiol"},{"key":"R31-20241021","first-page":"012005","article-title":"Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography","volume":"851","author":"Alshipli","year":"2017","journal-title":"InJournal of Physics:Conference Series"},{"key":"R32-20241021","first-page":"77","article-title":"Coronary CT angiography using iterative reconstruction vs. filtered back projection:Evaluation of image quality","volume":"86","author":"Arcadi","year":"2015","journal-title":"Acta Biomed"},{"key":"R33-20241021","first-page":"53","article-title":"CT number variations due to different image acquisition and reconstruction parameters:A thorax phantom study","volume":"24","author":"Groell","year":"2000","journal-title":"ComputMedImaging Graph"},{"key":"R34-20241021","first-page":"119","article-title":"Effect of iterative reconstruction on image quality in evaluating patients with coronary calcifications or stents during coronary computed tomography angiography:A pilot study","volume":"16","author":"G\u00fcler","year":"2016","journal-title":"AnatolJCardiol"},{"key":"R35-20241021","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.jcct.2011.05.002","article-title":"Iterative image reconstruction techniques:Applications for cardiac CT","volume":"5","author":"Renker","year":"2011","journal-title":"JCardiovasc Comput Tomogr"},{"key":"R36-20241021","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1148\/radiol.11102217","article-title":"Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages:Assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study","volume":"260","author":"Schindera","year":"2011","journal-title":"Radiology"},{"key":"R37-20241021","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1007\/BF03178591","article-title":"CT-ED conversion on a GE Lightspeed-RT scanner:Influence of scanner settings","volume":"31","author":"Ebert","year":"2008","journal-title":"Australas Phys Eng Sci Med"},{"key":"R38-20241021","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1017\/S1460396907006097","article-title":"Commissioning a new CT simulator I:CT simulator hardware","volume":"6","author":"Kearns","year":"2007","journal-title":"J Radiother Pract"},{"key":"R39-20241021","first-page":"149","article-title":"Evaluation of effect of different computed tomography scanning protocols on hounsfield unit and its impact on dose calculation by treatment planning system","volume":"14","author":"Mahur","year":"2017","journal-title":"Iran J Med Phys"},{"key":"R40-20241021","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1148\/radiol.2421052066","article-title":"Multi\u2013detector row CT attenuation measurements:Assessment of intra-and interscanner variability with an anthropomorphic body CT phantom","volume":"242","author":"Birnbaum","year":"2007","journal-title":"Radiology"},{"key":"R41-20241021","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1097\/00004728-200605000-00008","article-title":"Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT:A phantom and human study","volume":"30","author":"Kalva","year":"2006","journal-title":"JComput Assist Tomogr"},{"key":"R42-20241021","first-page":"40","article-title":"Effect of CT acquisition parameters in the detection of subtle hypoattenuation in acute cerebral infarction:A phantom study","volume":"27","author":"Tanaka","year":"2006","journal-title":"AmJ Neuroradiol"},{"key":"R44-20241021","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1007\/s12094-015-1390-z","article-title":"The effect of slice thickness on target and organs at risk volumes, dosimetric coverage and radiobiological impact in IMRT planning","volume":"18","author":"Srivastava","year":"2016","journal-title":"Clin Transl Oncol"},{"key":"R45-20241021","doi-asserted-by":"crossref","first-page":"3749","DOI":"10.1088\/0031-9155\/59\/14\/3749","article-title":"Influence of image slice thickness on rectal dose\u2013response relationships following radiotherapy of prostate cancer","volume":"59","author":"Olsson","year":"2014","journal-title":"Phys Med Biol"},{"key":"R46-20241021","first-page":"44","article-title":"Evaluation of the high definition field of view option of a large-bore computed tomography scanner for radiation therapy simulation","volume":"13","author":"Wu","year":"2020","journal-title":"PhysImaging Radiat Oncol"},{"key":"R47-20241021","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.phro.2017.03.001","article-title":"Clinical evaluation of a novel CT image reconstruction algorithmfor direct dose calculations","volume":"2","author":"van der Heyden","year":"2017","journal-title":"Phys Imaging Radiat Oncol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_260_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:38:21Z","timestamp":1787067501000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_260_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_260_21","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]},"assertion":[{"value":"2021-02-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-02-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}