{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:17:21Z","timestamp":1787840241489,"version":"build-2784847793"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Stereotactic body radiation therapy (SBRT) has been increasingly used to treat liver malignancies because large doses of radiation can be delivered precisely to the target with a rapid dose falloff. Real-time tracking of implanted fiducial markers (FMs), combined with respiratory gating, further improves the accuracy of treatment delivery and reduces the dose to critical structures. There have been reports of migration of the FMs after implantation for SBRT. Calypso beacons, which use the electromagnetic wave reflections for the image guidance, have recently been used for image-guided liver SBRT. In the literature, there are no reports on the migration of Calypso beacons to the heart after implantation in the liver. In this report, we detail the first case of such migration. Respiratory-gated SBRT guided by the Calypso system was planned for our patient, who developed liver metastases in segments 6 and 5\/4B shortly after the completion of radical chemoradiotherapy for anal squamous cell carcinoma. One of the three Calypso beacons inserted in the liver under computed tomography (CT) guidance was found to have migrated to the right ventricle, as seen in CT simulation images. SBRT was delivered with respiratory gating using the remaining two beacons. A fluoroscopic imaging performed during treatment confirmed the migrated marker to the right ventricle. Patient denied any cardiac symptoms and SBRT were delivered uneventfully. Ten months later, the patient died of disease progression.<\/jats:p>","DOI":"10.4103\/jcrt.jcrt_2654_22","type":"journal-article","created":{"date-parts":[[2024,1,23]],"date-time":"2024-01-23T13:00:57Z","timestamp":1706014857000},"page":"1628-1631","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Cardiac migration of an implanted hepatic fiducial marker used for stereotactic body radiation therapy - A case report"],"prefix":"10.4103","volume":"20","author":[{"given":"Youstina","family":"Soliman","sequence":"first","affiliation":[{"name":"Department of Medicine, University of Toronto, Toronto, ON, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Febin","family":"Antony","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Cancer Care Manitoba, Winnipeg, MB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Vivian","sequence":"additional","affiliation":[{"name":"Department of Radiology, Health Science Centre, Winnipeg, MB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sankar","family":"Venkatraman","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Health Science Centre, Winnipeg, MB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maged","family":"Nashed","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Health Science Centre, Winnipeg, MB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,22]]},"reference":[{"key":"R1-20241226","doi-asserted-by":"crossref","first-page":"4078","DOI":"10.1118\/1.3438081","article-title":"Stereotactic body radiation therapy:The report of AAPM Task Group 101 [published correction appears in Med Phys 2012;39:563. Dosage error in article text]","volume":"37","author":"Benedict","year":"2010","journal-title":"Med Phys"},{"key":"R2-20241226","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1634\/theoncologist.2012-0092","article-title":"Review and uses of stereotactic body radiation therapy for oligometastases","volume":"17","author":"Alongi","year":"2012","journal-title":"Oncologist"},{"key":"R3-20241226","doi-asserted-by":"crossref","first-page":"145","DOI":"10.3322\/caac.20013","article-title":"Local surgical, ablative, and radiation treatment of metastases","volume":"59","author":"Timmerman","year":"2009","journal-title":"CA Cancer J Clin"},{"key":"R4-20241226","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.prro.2011.10.005","article-title":"Continuous localization technologies for radiotherapy delivery:Report of the American Society for Radiation Oncology Emerging Technology Committee","volume":"2","author":"D'Ambrosio","year":"2012","journal-title":"Pract Radiat Oncol"},{"key":"R5-20241226","doi-asserted-by":"crossref","first-page":"e0179676","DOI":"10.1371\/journal.pone.0179676","article-title":"Efficacy and safety of ultrasound-guided implantation of fiducial markers in the liver for stereotactic body radiation therapy","volume":"12","author":"Park","year":"2017","journal-title":"PLoS One"},{"key":"R6-20241226","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/S0167-8140(02)00017-8","article-title":"Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)","volume":"62","author":"Kitamura","year":"2002","journal-title":"Radiother Oncol"},{"key":"R7-20241226","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1017\/S1460396914000223","article-title":"Calypso\u00ae 4D Localization System:A review","volume":"13","author":"Silva","year":"2014","journal-title":"J Radiother Pract"},{"key":"R8-20241226","doi-asserted-by":"crossref","first-page":"143","DOI":"10.4103\/0971-6203.116376","article-title":"Commissioning and quality assurance of Calypso four-dimensional target localization system in linear accelerator facility","volume":"38","author":"Muralidhar","year":"2013","journal-title":"J Med Phys"},{"key":"R9-20241226","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1080\/13645706.2019.1663217","article-title":"Percutaneous insertion of hepatic fiducial true-spherical markers for real-time adaptive radiotherapy","volume":"29","author":"Morita","year":"2020","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"R10-20241226","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jvir.2018.08.029","article-title":"Left Cardiac Migration of a Lung Fiducial Marker","volume":"30","author":"Cousin","year":"2019","journal-title":"J Vasc Interv Radiol"},{"key":"R11-20241226","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1186\/1752-1947-3-140","article-title":"Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy:A case report","volume":"3","author":"Hennessey","year":"2009","journal-title":"J Med Case Rep"},{"key":"R12-20241226","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.radonc.2016.07.023","article-title":"Fiducial marker guided stereotactic liver radiotherapy:Is a time delay between marker implantation and planning CT needed?","volume":"121","author":"Worm","year":"2016","journal-title":"Radiother Oncol"},{"key":"R13-20241226","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/S0360-3016(03)00076-2","article-title":"Feasibility of insertion\/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy","volume":"56","author":"Shirato","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R14-20241226","doi-asserted-by":"crossref","first-page":"314","DOI":"10.5946\/ce.2021.102","article-title":"Endoscopic Ultrasound-Guided Fiducial Placement for Stereotactic Body Radiation Therapy in Pancreatic Malignancy","volume":"54","author":"Kim","year":"2021","journal-title":"Clin Endosc"},{"key":"R15-20241226","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1111\/echo.12795","article-title":"Foreign bodies in the heart","volume":"32","author":"Leitman","year":"2015","journal-title":"Echocardiography"},{"key":"R16-20241226","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.brachy.2006.08.004","article-title":"Prostate brachytherapy seed migration to the right coronary artery associated with an acute myocardial infarction","volume":"5","author":"Zhu","year":"2006","journal-title":"Brachytherapy"},{"key":"R17-20241226","doi-asserted-by":"crossref","first-page":"2312","DOI":"10.1016\/j.jaccas.2020.07.035","article-title":"Migration of a Varicocele Coil to the Right Heart","volume":"2","author":"Karia","year":"2020","journal-title":"JACC Case Rep"},{"key":"R18-20241226","doi-asserted-by":"crossref","first-page":"25","DOI":"10.21037\/acr-22-6","article-title":"Migration of Calypso beacon transponders for hepatic stereotactic body radiotherapy:A report of two cases","volume":"6","author":"Amjad","year":"2022","journal-title":"AME Case Rep"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_2654_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:18:08Z","timestamp":1787836688000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_2654_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,22]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_2654_22","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,22]]},"assertion":[{"value":"2022-12-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-02-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}