{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:35:02Z","timestamp":1787070902594,"version":"build-2736575974"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Context:<\/jats:title>\n                    <jats:p>Rotation corrected set-up margins in stereotactic radiotherapy (SRT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>This study aimed to calculate the rotational positional error corrected set-up margin in frameless SRT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>6D setup errors for the steriotactic radiotherapy patients were converted to 3D translational only error mathematically. Setup margins were calculated with and without considering the rotational error and compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A total of 79 patients of SRT each received &gt;1 fraction (3\u20136 fractions) incorporated in this study. Two cone-beam computed tomography (CBCT) scans were acquired for each session of treatment, before and after the robotic couch-aided patient position correction using a CBCT. The postpositional correction set-up margin was calculated using the van Herk formula. Further, a planning target volume_R (PTV_R) (with rotational correction) and PTV_NR (without rotational correction) were calculated by applying the rotation corrected and uncorrected set-up margins on the gross tumor volumes (GTVs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>General.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 380 sessions of pre- (190) and post (190) table positional correction CBCT was analyzed. Posttable position correction mean positional error for lateral, longitudinal, and vertical translational and rotational shifts was (x)-0.01 \u00b1 0.05 cm, (y)-0.02 \u00b1 0.05 cm, (z) 0.00 \u00b1 0.05 cm, and (q) 0.04\u00b0 \u00b1 0.3\u00b0, (F) 0.1\u00b0 \u00b1 0.4\u00b0, (Y) 0.0\u00b0 \u00b1 0.4\u00b0, respectively. The GTV volumes show a range of 0.13 cc\u201339.56 cc, with a mean volume of 6.35 \u00b1 8.65 cc. Rotational correction incorporated postpositional correction set-up margin the in lateral (x), longitudinal (y) and vertical (z) directions were 0.05 cm, 0.12 cm, and 0.1 cm, respectively. PTV_R ranges from 0.27 cc to 44.7 cc, with a mean volume of 7.7 \u00b1 9.8 cc. PTV_NR ranges from 0.32 cc to 46.0 cc, with a mean volume of 8.1 \u00b1 10.1 cc.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The postcorrection linear set-up margin matches well with the conventional set-up margin of 1 mm. Beyond a GTV radius of 2 cm, the difference between PTV_NR and PTV_R is \u22642.5%, hence not significant.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_359_21","type":"journal-article","created":{"date-parts":[[2022,5,9]],"date-time":"2022-05-09T07:52:03Z","timestamp":1652082723000},"page":"169-176","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Calculation of set-up margin in frameless stereotactic radiotherapy accounting for translational and rotational patient positing error"],"prefix":"10.4103","volume":"19","author":[{"given":"Arjunan","family":"Manikandan","sequence":"first","affiliation":[{"name":"Department of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India"},{"name":"Department of Medical Physics, Bharathiar University, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Biplab","family":"Sarkar","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology , Apollo Multispeciality Hospital, Kolkata, West Bengal, India"},{"name":"Department of Physics, GLA University, Mathura, UP, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anusheel","family":"Munshi","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Manipal Hospital, Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saneg","family":"Krishnankutty","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Fortis Memorial Research Institute, Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tharmarnadar","family":"Ganesh","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Manipal Hospital, Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bidhu Kalyan","family":"Mohanti","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Manipal Hospital, Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujatha","family":"Manikandan","sequence":"additional","affiliation":[{"name":"Department of Radiotherapy, Government General Hospital, Guntur, Andhra Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pradhan","family":"Anirudh","sequence":"additional","affiliation":[{"name":"Director, Centre of Cosmology, Astrophysics and Space Science (CCASS), GLA University, Mathura, UP, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Surekha","family":"Chandrasekharan","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Bharathiar University, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,5,3]]},"reference":[{"key":"R1-20241021","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1016\/j.ijrobp.2008.12.025","article-title":"Influence of rotations on dose distributions in spinal stereotactic body radiotherapy (SBRT)","volume":"73","author":"Gutfeld","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R2-20241021","doi-asserted-by":"crossref","first-page":"e555","DOI":"10.1016\/j.ijrobp.2011.06.1980","article-title":"Spine stereotactic body radiotherapy utilizing cone-beam CT image-guidance with a robotic couch: Intrafraction motion analysis accounting for all six degrees of freedom","volume":"82","author":"Hyde","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R3-20241021","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/j.ijrobp.2008.02.074","article-title":"Dosimetric effect of translational and rotational errors for patients undergoing image-guided stereotactic body radiotherapy for spinal metastases","volume":"71","author":"Wang","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R4-20241021","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1016\/S0360-3016(02)03014-6","article-title":"Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma","volume":"54","author":"Onimaru","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R5-20241021","doi-asserted-by":"crossref","first-page":"3422","DOI":"10.1120\/jacmp.v12i3.3422","article-title":"Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy","volume":"12","author":"Peng","year":"2011","journal-title":"J Appl Clin Med Phys"},{"key":"R6-20241021","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.radonc.2011.06.013","article-title":"Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patients","volume":"102","author":"Beltran","year":"2012","journal-title":"Radiother Oncol"},{"key":"R7-20241021","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/1748-717X-7-63","article-title":"Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery","volume":"7","author":"Guckenberger","year":"2012","journal-title":"Radiat Oncol"},{"key":"R8-20241021","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1120\/jacmp.v16i2.5102","article-title":"Estimation of patient setup uncertainty using BrainLAB Exatrac X-Ray 6D system in image-guided radiotherapy","volume":"16","author":"Infusino","year":"2015","journal-title":"J Appl Clin Med Phys"},{"key":"R9-20241021","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/S0360-3016(00)00518-6","article-title":"The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy","volume":"47","author":"van Herk","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R10-20241021","first-page":"52","article-title":"Errors and margins in radiotherapy. InSeminars in radiation oncology","volume":"14","author":"Van Herk","year":"2004","journal-title":"WB Saunders"},{"key":"R11-20241021","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/S0360-3016(98)00468-4","article-title":"Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability","volume":"43","author":"Stroom","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R12-20241021","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1016\/j.ijrobp.2006.11.010","article-title":"Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table","volume":"67","author":"Meyer","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R13-20241021","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.meddos.2008.02.005","article-title":"Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy","volume":"33","author":"Jin","year":"2008","journal-title":"Med Dosim"},{"key":"R14-20241021","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0167-8140(02)00385-7","article-title":"Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging","volume":"67","author":"Verellen","year":"2003","journal-title":"Radiother Oncol"},{"key":"R15-20241021","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0031-9155\/55\/1\/001","article-title":"The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system","volume":"55","author":"Takakura","year":"2010","journal-title":"Phys Med Biol"},{"key":"R16-20241021","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1016\/j.ijrobp.2011.01.052","article-title":"Setup accuracy of the Novalis ExacTrac 6DOF system for frameless radiosurgery","volume":"82","author":"Gevaert","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R17-20241021","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.ijrobp.2011.05.048","article-title":"Clinical evaluation of a robotic 6-degree of freedom treatment couch for frameless radiosurgery","volume":"83","author":"Gevaert","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R18-20241021","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/s00066-007-1695-0","article-title":"Precision of image-guided radiotherapy (IGRT) in six degrees of freedom and limitations in clinical practice","volume":"183","author":"Guckenberger","year":"2007","journal-title":"Strahlenther Onkol"},{"key":"R19-20241021","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/1748-717X-5-42","article-title":"Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results","volume":"5","author":"Wilbert","year":"2010","journal-title":"Radiat Oncol"},{"key":"R20-20241021","first-page":"1606","article-title":"Positional errors in linear accelerator based frameless cranial stereotaxy: A note of caution","volume":"22","author":"Sarkar","year":"2017","journal-title":"J BUON"},{"key":"R21-20241021","doi-asserted-by":"crossref","first-page":"075004","DOI":"10.1088\/1361-6560\/aab231","article-title":"Methodology to reduce 6D patient positional shifts into a 3D linear shift and its verification in frameless stereotactic radiotherapy","volume":"63","author":"Sarkar","year":"2018","journal-title":"Phys Med Biol"},{"key":"R22-20241021","first-page":"1","article-title":"Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and ExacTrac stereoscopic imaging","volume":"2021","author":"Sarkar","journal-title":"La radiologia medica"},{"key":"R23-20241021","doi-asserted-by":"crossref","first-page":"4749","DOI":"10.1002\/mp.13810","article-title":"Rotational positional error corrected intrafraction set-up margins in stereotactic radiotherapy: A spatial assessment for coplanar and noncoplanar geometry","volume":"46","author":"Sarkar","year":"2019","journal-title":"Med Phys"},{"key":"R24-20241021","doi-asserted-by":"crossref","first-page":"3436","DOI":"10.1118\/1.4956034","article-title":"SU-F-J-126: Influence of six dimensional motions in frameless stereotactic dosimetry incorporating rotational shifts as equivalent translational shifts: A feasibility study for Elekta-BrainLAB stereotactic system","volume":"43","author":"Sarkar","year":"2016","journal-title":"Med Phys"},{"key":"R25-20241021","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.ijrobp.2015.08.010","article-title":"In regard to Onimaru. et al","volume":"93","author":"Sarkar","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R26-20241021","doi-asserted-by":"crossref","first-page":"166","DOI":"10.4103\/0019-509X.180815","article-title":"Do technological advances in linear accelerators improve dosimetric outcomes in stereotaxy? A head-on comparison of seven linear accelerators using volumetric modulated arc therapy-based stereotactic planning","volume":"53","author":"Sarkar","year":"2016","journal-title":"Indian J Cancer"},{"key":"R27-20241021","article-title":"Margins and Margin Recipes","author":"van Herk"},{"key":"R28-20241021","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.ejmp.2016.02.002","article-title":"Setup uncertainties in linear accelerator based stereotactic radiosurgery and a derivation of the corresponding setup margin for treatment planning","volume":"32","author":"Zhang","year":"2016","journal-title":"Phys Med"},{"key":"R29-20241021","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.meddos.2015.12.006","article-title":"Evaluation of the setup margins for cone beam computed tomography-guided cranial radiosurgery: A phantom study","volume":"41","author":"Calvo Ortega","year":"2016","journal-title":"Med Dosim"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_359_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:38:37Z","timestamp":1787067517000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_359_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,3]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_359_21","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,3]]},"assertion":[{"value":"2021-03-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}