{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T15:01:11Z","timestamp":1792854071608,"version":"4.5.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>The study aims to compare the accuracy and safety of robotic-assisted navigation puncture to freehand puncture during computed tomography (CT)-guided percutaneous needle insertion in the chest and abdomen.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 60 patients required percutaneous puncture procedures, with 40 involving the chest and 20 involving the abdomen. Eligible patients were randomly assigned to two groups. The test group punctured using a robotic-assisted navigation system, whereas the control group punctured manually. The primary outcome assessment standards are single puncture success rates, with the number of needle modifications and CT scan timings during the procedure serving as supplementary outcome evaluation standards. The Wilcoxon rank sum test is used for the comparison.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The puncture procedure\u2019s success rates after just one puncture: The test group punctures accurately without adjusting the puncture needle, while the control group uses an average number of 1.73 \u00b1 1.20 pins. The once-puncture success rate of robot navigation puncture is considerably higher than that of bare-handed puncture (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). The times of CT scan are necessitated when the puncture is in place: the average times in the test group is 3.03 \u00b1 0.18 times, while the control group is 4.70 \u00b1 1.24 times.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In conclusion, the robotic-assisted navigation system improves puncture accuracy while reducing the need for needle corrections during percutaneous puncture procedures. It also shortens CT scans and reduces radiation exposure from X-rays.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_373_24","type":"journal-article","created":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T11:52:10Z","timestamp":1724932330000},"page":"1350-1356","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":13,"title":["Evaluation of robotic-assisted navigation system for CT-guided thoracic and abdominal lesion puncture: A prospective clinical study"],"prefix":"10.4103","volume":"20","author":[{"given":"Yifan","family":"Jing","sequence":"first","affiliation":[{"name":"Department of Interventional Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Interventional Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Jin","sequence":"additional","affiliation":[{"name":"Department of Interventional Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuming","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Interventional Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,8,29]]},"reference":[{"key":"R1-20241021","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.2174\/1573405613666170621085950","article-title":"Clinical application of percutaneous puncture biopsy guided by fused and 3D-reconstructed PET\/CT images","volume":"14","author":"Dong","year":"2018","journal-title":"Curr Med Imaging Rev"},{"key":"R2-20241021","doi-asserted-by":"crossref","first-page":"418","DOI":"10.4103\/jcrt.jcrt_546_21","article-title":"Safety and efficacy of percutaneous microwave ablation using combined computed tomography and ultrasound-guided imaging in patients with hepatocellular carcinoma:A retrospective study","volume":"18","author":"Zhao","year":"2022","journal-title":"J Cancer Res Ther"},{"key":"R3-20241021","doi-asserted-by":"crossref","first-page":"345","DOI":"10.4103\/jcrt.jcrt_1078_21","article-title":"Efficacy and safety of transcatheter arterial chemoembolization plus hepatic arterial infusion chemotherapy in the treatment of advanced hepatocellular carcinoma with portal vein tumor thrombosis in the main trunk","volume":"18","author":"Wu","year":"2022","journal-title":"J Cancer Res Ther"},{"key":"R4-20241021","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3348\/kjr.2020.0137","article-title":"2020 Clinical Practice Guideline for percutaneous transthoracic needle biopsy of pulmonary lesions:A consensus statement and recommendations of the Korean Society of Thoracic Radiology","volume":"22","author":"Yoon","year":"2021","journal-title":"Korean J Radiol"},{"key":"R5-20241021","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1080\/07357907.2018.1498877","article-title":"Percutaneous computed tomography-guided lung biopsies using a virtual navigation guidance:Our experience","volume":"36","author":"Iannelli","year":"2018","journal-title":"Cancer Invest"},{"key":"R6-20241021","doi-asserted-by":"crossref","first-page":"e0173751","DOI":"10.1371\/journal.pone.0173751","article-title":"Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions:A prospective randomized clinical trial","volume":"12","author":"Durand","year":"2017","journal-title":"PLoS One"},{"key":"R7-20241021","doi-asserted-by":"crossref","first-page":"110753","DOI":"10.1016\/j.ejrad.2023.110753","article-title":"Evaluation of the performance of robot assisted CT-guided percutaneous needle insertion:Comparison with freehand insertion in a phantom","volume":"162","author":"Spenkelink","year":"2023","journal-title":"Eur J Radiol"},{"key":"R8-20241021","doi-asserted-by":"crossref","first-page":"5218","DOI":"10.1038\/s41598-021-84878-3","article-title":"Feasibility, safety and accuracy of a CT-guided robotic assistance for percutaneous needle placement in a swine liver model","volume":"11","author":"Guiu","year":"2021","journal-title":"Sci Rep"},{"key":"R9-20241021","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/s41747-022-00265-1","article-title":"Robotic assistance for percutaneous needle insertion in the kidney:Preclinical proof on a swine animal model","volume":"6","author":"de","year":"2022","journal-title":"Eur Radiol Exp"},{"key":"R10-20241021","doi-asserted-by":"crossref","first-page":"210","DOI":"10.3348\/kjr.2012.13.2.210","article-title":"CT-guided percutaneous biopsy of intrathoracic lesions","volume":"13","author":"Lal","year":"2012","journal-title":"Korean J Radiol"},{"key":"R11-20241021","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/j.diii.2020.07.007","article-title":"Percutaneous CT-guided lung biopsy for the diagnosis of persistent pulmonary consolidation","volume":"101","author":"Brioulet","year":"2020","journal-title":"Diagn Interv Imaging"},{"key":"R12-20241021","doi-asserted-by":"crossref","first-page":"904","DOI":"10.4103\/jcrt.jcrt_1290_22","article-title":"Comparison of core needle biopsy and fine-needle aspiration methods in CT-guided percutaneous sampling of pancreatic tumors","volume":"19","author":"Liu","year":"2023","journal-title":"J Cancer Res Ther"},{"key":"R13-20241021","doi-asserted-by":"crossref","first-page":"651","DOI":"10.4103\/jcrt.jcrt_2017_23","article-title":"Enhanced recovery after surgery for percutaneous CT-guided microwave ablation of lung tumors:A single-center retrospective cohort study","volume":"20","author":"Peng","year":"2024","journal-title":"J Cancer Res Ther"},{"key":"R14-20241021","doi-asserted-by":"crossref","first-page":"399","DOI":"10.4103\/jcrt.jcrt_1965_21","article-title":"A study of microwave ablation for small cell lung cancer","volume":"18","author":"Wang","year":"2022","journal-title":"J Cancer Res Ther"},{"key":"R15-20241021","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1007\/s00330-014-3391-7","article-title":"Robotic-assisted thermal ablation of liver tumours","volume":"25","author":"Abdullah","year":"2015","journal-title":"Eur Radiol"},{"key":"R16-20241021","doi-asserted-by":"crossref","first-page":"193","DOI":"10.2214\/AJR.15.15803","article-title":"Stereotactic CT-guided percutaneous microwave ablation of liver tumors with the use of high-frequency jet ventilation:An accuracy and procedural safety study","volume":"208","author":"Engstrand","year":"2017","journal-title":"AJR Am J Roentgenol"},{"key":"R17-20241021","doi-asserted-by":"crossref","first-page":"323","DOI":"10.3348\/kjr.2018.0064","article-title":"Analysis of complications of percutaneous transthoracic needle biopsy using ct-guidance modalities in a multicenter cohort of 10568 biopsies","volume":"20","author":"Yoon","year":"2019","journal-title":"Korean J Radiol"},{"key":"R18-20241021","doi-asserted-by":"crossref","first-page":"369","DOI":"10.3906\/sag-1908-73","article-title":"Evaluation of major complications associated with percutaneous CT-guided biopsy of lung nodules below 3 cm","volume":"50","author":"Cakir","year":"2020","journal-title":"Turk J Med Sci"},{"key":"R19-20241021","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1007\/s00330-019-06477-1","article-title":"Robotic CT-guided out-of-plane needle insertion:Comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals","volume":"30","author":"Komaki","year":"2019","journal-title":"Eur Radiol"},{"key":"R20-20241021","doi-asserted-by":"crossref","first-page":"470","DOI":"10.5152\/dir.2014.13463","article-title":"Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions","volume":"20","author":"Jiao","year":"2014","journal-title":"Diagn Interv Radiol"},{"key":"R21-20241021","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1007\/s00464-015-4261-3","article-title":"Laparoscopic microwave thermosphere ablation of malignant liver tumors:An initial clinical evaluation","volume":"30","author":"Berber","year":"2016","journal-title":"Surg Endosc"},{"key":"R22-20241021","doi-asserted-by":"crossref","first-page":"1440","DOI":"10.1016\/j.jvir.2018.01.002","article-title":"Evaluation of a CT-guided robotic system for precise percutaneous needle insertion","volume":"29","author":"Ben-David","year":"2018","journal-title":"J Vasc Interv Radiol"},{"key":"R23-20241021","doi-asserted-by":"crossref","first-page":"S356","DOI":"10.1016\/j.hpb.2020.04.373","article-title":"Robotic versus freehand needle positioning in CT-guided ablation of liver tumors:A randomized controlled trial","volume":"22","author":"Jong","year":"2020","journal-title":"HPB"},{"key":"R24-20241021","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/s11548-015-1286-y","article-title":"Robot-assisted microwave thermoablation of liver tumors:A single-center experience","volume":"11","author":"Beye","year":"2016","journal-title":"Int J Computer Assist Radiol Surg"},{"key":"R25-20241021","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1109\/TITB.2002.806089","article-title":"Technology improvements for image-guided and minimally invasive spine procedures","volume":"6","author":"Cleary","year":"2002","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"R26-20241021","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/S0033-8389(05)70165-2","article-title":"CT fluoroscopy for thoracic interventional procedures","volume":"38","author":"White","year":"2000","journal-title":"Radiol Clin North Am"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_373_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:43:02Z","timestamp":1787067782000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_373_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_373_24","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"2024-02-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}