{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:35:39Z","timestamp":1787070939928,"version":"build-2736575974"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>The spot position is an important beam parameter in the quality assurance of scanning proton therapy. In this study, we investigated dosimetric impact of systematic 15 spot position errors (SSPE) in spot scanning proton therapy using three types of optimization methods of head and neck tumor.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      The planning simulation was performed with \u00b1 2 mm model SSPE in the X and Y directions. Treatment plans were created using intensity-modulated proton therapy (IMPT) and single-field uniform dose (SFUD). IMPT plans were created by two optimization methods: with worst-case optimization (WCO-IMPT) and without (IMPT). For clinical target volume (CTV), D95%, D50%, and D2cc were used for analysis. For organs at risk (OAR), D\n                      <jats:sub>mean<\/jats:sub>\n                      was used to analyze the brain, cochlea, and parotid, and D\n                      <jats:sub>max<\/jats:sub>\n                      was used to analyze brainsetem, chiasm, optic nerve, and cord.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      For CTV, the variation (1 standard deviation) of D95% was \u00b1 0.88%, 0.97% and 0.97% to WCO-IMPT, IMPT, and SFUD plan. The variation of D50% and D2cc of CTV showed &lt;0.5% variation in all plans. The dose variation due to SSPE was larger in OAR, and worst-case optimization reduced the dose variation, especially in D\n                      <jats:sub>max<\/jats:sub>\n                      . The analysis results showed that SSPE has little impact on SFUD.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>We clarified the impact of SSPE on dose distribution for three optimization methods. SFUD was shown to be a robust treatment plan for OARs, and the WCO can be used to increase robustness to SSPE in IMPT.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_389_21","type":"journal-article","created":{"date-parts":[[2023,1,11]],"date-time":"2023-01-11T22:47:49Z","timestamp":1673477269000},"page":"S228-S233","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Dosimetric impact of systematic spot position errors in spot scanning proton therapy of head and neck tumor"],"prefix":"10.4103","volume":"19","author":[{"given":"Keisuke","family":"Yasui","sequence":"first","affiliation":[{"name":"Fujita Health University, School of Health Sciences, Faculty of Radiological Technology, Toyoake, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuta","family":"Omi","sequence":"additional","affiliation":[{"name":"Anjo Kosei Hospital, Anjo, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Shimomura","sequence":"additional","affiliation":[{"name":"Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Nagoya, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rie","family":"Muramatsu","sequence":"additional","affiliation":[{"name":"Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Nagoya, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiromitsu","family":"Iwata","sequence":"additional","affiliation":[{"name":"Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Nagoya, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Ogino","sequence":"additional","affiliation":[{"name":"Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Nagoya, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Hayashi","sequence":"additional","affiliation":[{"name":"Fujita Health University, School of Health Sciences, Faculty of Radiological Technology, Toyoake, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,1,12]]},"reference":[{"key":"R1-20241021","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1088\/0031-9155\/44\/1\/014","article-title":"Intensity modulation methods for proton radiotherapy","volume":"44","author":"Lomax","year":"1999","journal-title":"Phys Med Biol"},{"key":"R2-20241021","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1118\/1.3314073","article-title":"Intensity modulated proton therapy treatment planning using single-field optimization:The impact of monitor unit constraints on plan quality","volume":"37","author":"Zhu","year":"2010","journal-title":"Med Phys"},{"key":"R3-20241021","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1748-717X-9-202","article-title":"A single-field integrated boost treatment planning technique for spot scanning proton therapy","volume":"9","author":"Zhu","year":"2014","journal-title":"Radiat Oncol"},{"key":"R4-20241021","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1118\/1.1350587","article-title":"Intensity modulated proton therapy:A clinical example","volume":"28","author":"Lomax","year":"2001","journal-title":"Med Phys"},{"key":"R5-20241021","doi-asserted-by":"crossref","first-page":"3150","DOI":"10.1118\/1.1779371","article-title":"Treatment planning and verification of proton therapy using spot scanning:Initial experiences","volume":"31","author":"Lomax","year":"2004","journal-title":"Med Phys"},{"key":"R6-20241021","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1088\/0031-9155\/53\/4\/014","article-title":"Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1:The potential effects of calculational uncertainties","volume":"53","author":"Lomax","year":"2008","journal-title":"Phys Med Biol"},{"key":"R7-20241021","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.ijrobp.2010.11.071","article-title":"Patient-specific quality assurance for prostate cancer patients receiving spot scanning proton therapy using single-field uniform dose","volume":"81","author":"Zhu","year":"2011","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R8-20241021","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1118\/1.3556559","article-title":"Minimax optimization for handling range and setup uncertainties in proton therapy","volume":"38","author":"Fredriksson","year":"2011","journal-title":"Med Phys"},{"key":"R9-20241021","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1118\/1.597522","article-title":"The 200-MeV proton therapy project at the Paul Scherrer Institute:Conceptual design and practical realization","volume":"22","author":"Pedroni","year":"1995","journal-title":"Med Phys"},{"key":"R10-20241021","doi-asserted-by":"crossref","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys Med Biol"},{"key":"R11-20241021","doi-asserted-by":"crossref","first-page":"e329","DOI":"10.1016\/j.ijrobp.2011.05.011","article-title":"A beam-specific planning target volume (PTV) design for proton therapy to account for setup and range uncertainties","volume":"82","author":"Park","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R12-20241021","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1088\/0031-9155\/53\/6\/013","article-title":"Worst case optimization:A method to account for uncertainties in the optimization of intensity modulated proton therapy","volume":"53","author":"Pflugfelder","year":"2008","journal-title":"Phys Med Biol"},{"key":"R13-20241021","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1118\/1.3021139","article-title":"Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning","volume":"36","author":"Unkelbach","year":"2009","journal-title":"Med Phys"},{"key":"R14-20241021","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.addr.2016.11.006","article-title":"Proton therapy \u2013Present and future","volume":"109","author":"Mohan","year":"2017","journal-title":"Adv Drug Deliv Rev"},{"key":"R15-20241021","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.semradonc.2017.11.005","article-title":"Robust proton treatment planning:Physical and biological optimization","volume":"28","author":"Unkelbach","year":"2018","journal-title":"Semin Radiat Oncol"},{"key":"R16-20241021","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1118\/1.3679340","article-title":"Robust optimization of intensity modulated proton therapy","volume":"39","author":"Liu","year":"2012","journal-title":"Med Phys"},{"key":"R17-20241021","doi-asserted-by":"crossref","first-page":"20190584","DOI":"10.1259\/bjr.20190584","article-title":"Assessment of robustness against setup uncertainties using probabilistic scenarios in lung cancer:A comparison of proton with photon therapy","volume":"93","author":"Teoh","year":"2020","journal-title":"Br J Radiol"},{"key":"R18-20241021","doi-asserted-by":"crossref","first-page":"570","DOI":"10.3109\/0284186X.2012.744874","article-title":"Robustness of IMPT treatment plans with respect to inter-fractional set-up uncertainties:Impact of various beam arrangements for cranial targets","volume":"52","author":"Hopfgartner","year":"2013","journal-title":"Acta Oncol"},{"key":"R19-20241021","doi-asserted-by":"crossref","first-page":"3923","DOI":"10.1002\/mp.12390","article-title":"Impact of spot charge inaccuracies in IMPT treatments","volume":"44","author":"Kraan","year":"2017","journal-title":"Med Phys"},{"key":"R20-20241021","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ejmp.2018.12.011","article-title":"Impact of spot size variations on dose in scanned proton beam therapy","volume":"57","author":"Kraan","year":"2019","journal-title":"Phys Med"},{"key":"R21-20241021","doi-asserted-by":"crossref","first-page":"e678","DOI":"10.1002\/mp.13622","article-title":"AAPM task group 224:Comprehensive proton therapy machine quality assurance","volume":"46","author":"Arjomandy","year":"2019","journal-title":"Med Phys"},{"key":"R22-20241021","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/acm2.12556","article-title":"Development and long-term stability of a comprehensive daily QA program for a modern pencil beam scanning (PBS) proton therapy delivery system","volume":"20","author":"Rana","year":"2019","journal-title":"J Appl Clin Med Phys"},{"key":"R23-20241021","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1088\/1361-6560\/aa5131","article-title":"A comprehensive and efficient daily quality assurance for PBS proton therapy","volume":"62","author":"Actis","year":"2017","journal-title":"Phys Med Biol"},{"key":"R24-20241021","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1088\/0031-9155\/61\/1\/400","article-title":"PBS machine interlocks using EWMA","volume":"61","author":"Clasie","year":"2016","journal-title":"Phys Med Biol"},{"key":"R25-20241021","first-page":"1","article-title":"Implication of spot position error on plan quality in pencil-beam proton therapy","volume":"081706","author":"Yu","year":"2014","journal-title":"Med Phys"},{"key":"R26-20241021","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1002\/acm2.12535","article-title":"Dosimetric verification of IMPT using a commercial heterogeneous phantom","volume":"20","author":"Yasui","year":"2019","journal-title":"J Appl Clin Med Phys"},{"key":"R27-20241021","doi-asserted-by":"crossref","first-page":"6999","DOI":"10.1118\/1.4935528","article-title":"A patient-specific aperture system with an energy absorber for spot scanning proton beams:Verification for clinical application","volume":"42","author":"Yasui","year":"2015","journal-title":"Med Phys"},{"key":"R28-20241021","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1002\/acm2.12231","article-title":"Evaluation of dosimetric advantages of using patient-specific aperture system with intensity-modulated proton therapy for the shallow depth tumor","volume":"19","author":"Yasui","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"R29-20241021","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1093\/jrr\/rrz036","article-title":"Proton therapy for non-squamous cell carcinoma of the head and neck:Planning comparison and toxicity","volume":"60","author":"Iwata","year":"2019","journal-title":"J Radiat Res"},{"key":"R30-20241021","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1007\/s13246-016-0456-8","article-title":"A proton therapy system in Nagoya Proton Therapy Center","volume":"39","author":"Toshito","year":"2016","journal-title":"Australas Phys Eng Sci Med"},{"key":"R31-20241021","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1088\/1361-6560\/aa5084","article-title":"Impacts of gantry angle dependent scanning beam properties on proton PBS treatment","volume":"62","author":"Lin","year":"2017","journal-title":"Phys Med Biol"},{"key":"R32-20241021","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1186\/s13014-019-1335-8","article-title":"Statistical evaluation of worst-case robust optimization intensity-modulated proton therapy plans using an exhaustive sampling approach","volume":"14","author":"Yang","year":"2019","journal-title":"Radiat Oncol"},{"key":"R33-20241021","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1186\/1748-717X-8-145","article-title":"Multi-scenario based robust intensity-modulated proton therapy (IMPT) plans can account for set-up errors more effectively in terms of normal tissue sparing than planning target volume (PTV) based intensity-modulated photon plans in the head and neck region","volume":"8","author":"Stuschke","year":"2013","journal-title":"Radiat Oncol"},{"key":"R34-20241021","first-page":"1","article-title":"Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance","volume":"021703","author":"Li","year":"2013","journal-title":"Med Phys"},{"key":"R35-20241021","doi-asserted-by":"crossref","first-page":"095021(11pp)","DOI":"10.1088\/1361-6560\/ab120c","article-title":"Impact of machine log-files uncertainties on the quality assurance of proton pencil beam scanning treatment delivery","volume":"64","author":"Toscano","year":"2019","journal-title":"Phys Med Biol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_389_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:39:17Z","timestamp":1787067557000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_389_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":35,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_389_21","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]},"assertion":[{"value":"2021-03-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}