{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:34:23Z","timestamp":1787070863215,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>The objective of the study was to evaluate the effectiveness of a rectal retractor (RR) designed to protect rectal tissue in intensity-modulated radiotherapy (IMRT) by pushing rectal wall (RW) away from the prostate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Twelve patients with localized prostate cancer were enrolled into this study. Patients underwent two computed tomography (CT) scans without and with RR. A prescription of 80 Gy in 40 fractions was planned on CT scans with and without RR. This study evaluates the ability of the RR in RW dose reduction, in particular reduction of the RW V\n                      <jats:sub>70Gy<\/jats:sub>\n                      \u2265 25% in comparison with the plan without RR dose-volume histograms were generated with and without RR. The patient's tolerance was assessed by patient-reported outcomes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The planning target volume coverage was equal for both without and with RR (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.155). The mean dose to the RW was statistically significantly lower for the plan with RR than that for the plan without RR, a mean reduction of 5.8 Gy (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003). Significant relative reductions in rectal dose-volume parameters whether in absolute volume (cc) or as a percentage of contoured RW were detected. A relative reduction more than 25% in RW V\n                      <jats:sub>70Gy<\/jats:sub>\n                      (%) in 100% of patients was achieved. The rectal retraction resulted in a significant increase in the prostate to the rectum space at the prostate midgland level, an absolute increase of 2.7 mm. The retraction of the rectum induced a mean (\u00b1standard deviation) pain score of 2.7 (\u00b11.3) according to the visual analog score.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The application of a RR showed a remarkable rectal sparing effect during prostate IMRT. This may lead to reduced acute and late rectal toxicities in prostate IMRT.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_701_19","type":"journal-article","created":{"date-parts":[[2021,6,18]],"date-time":"2021-06-18T03:13:21Z","timestamp":1623986001000},"page":"383-388","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Rectal wall sparing effect of a rectal retractor in prostate intensity-modulated radiotherapy"],"prefix":"10.4103","volume":"17","author":[{"given":"Hamed","family":"Ghaffari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aram","family":"Rostami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahdieh Afkhami","family":"Ardekani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bahram","family":"Mofid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seied Rabi","family":"Mahdavi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-13-20241021","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/S0360-3016(02)02829-8","article-title":"Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial","volume":"53","author":"Pollack","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R2-13-20241021","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/S1470-2045(07)70143-2","article-title":"Escalated-dose versus standard-dose conformal radiotherapy in prostate cancer:First results from the MRC RT01 randomised controlled trial","volume":"8","author":"Dearnaley","year":"2007","journal-title":"Lancet Oncol"},{"key":"R3-13-20241021","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1016\/j.ijrobp.2007.11.044","article-title":"Incidence of late rectal and urinary toxicities after three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for localized prostate cancer","volume":"70","author":"Zelefsky","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R4-13-20241021","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/j.ijrobp.2008.04.063","article-title":"Role of intensity-modulated radiotherapy in reducing toxicity in dose escalation for localized prostate cancer","volume":"73","author":"Al-Mamgani","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R5-13-20241021","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.radonc.2010.04.016","article-title":"Is there a role for endorectal balloons in prostate radiotherapy? A systematic review","volume":"95","author":"Smeenk","year":"2010","journal-title":"Radiother Oncol"},{"key":"R6-13-20241021","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.ijrobp.2014.06.044","article-title":"Optimization of radiation therapy techniques for prostate cancer with prostate-rectum spacers: A systematic review","volume":"90","author":"Mok","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R7-13-20241021","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1002\/jmrs.238","article-title":"Rectal protection in prostate stereotactic radiotherapy: A retrospective exploratory analysis of two rectal displacement devices","volume":"64","author":"Wilton","year":"2017","journal-title":"J Med Radiat Sci"},{"key":"R8-13-20241021","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1155\/2014\/680205","article-title":"Decreasing the dose to the rectal wall by using a rectal retractor during radiotherapy of prostate cancer: A comparative treatment planning study","volume":"2014","author":"Nilsson","year":"2014","journal-title":"J Radiother"},{"key":"R9-13-20241021","doi-asserted-by":"crossref","first-page":"500","DOI":"10.3109\/02841861003745535","article-title":"A method to separate the rectum from the prostate during proton beam radiotherapy of prostate cancer patients","volume":"49","author":"Isacsson","year":"2010","journal-title":"Acta Oncol"},{"key":"R10-13-20241021","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1186\/s13014-015-0426-4","article-title":"Clinical evaluation of an endorectal immobilization system for use in prostate hypofractionated Stereotactic Ablative Body Radiotherapy (SABR)","volume":"10","author":"Nicolae","year":"2015","journal-title":"Radiat Oncol"},{"key":"R11-13-20241021","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1007\/s00066-019-01445-6","article-title":"Rectal retractor application during image-guided dose-escalated prostate radiotherapy","volume":"195","author":"Mahdavi","year":"2019","journal-title":"Strahlenther Onkol"},{"key":"R12-13-20241021","first-page":"E254","article-title":"Rectal sparing using a rectal retractor during dose escalated prostate radiotherapy","volume":"45","author":"Ghaffari","year":"2018","journal-title":"Med Phys"},{"key":"R13-13-20241021","first-page":"15","article-title":"Fiducial markers in prostate cancer image-guided radiotherapy","volume":"33","author":"Ghaffari","year":"2019","journal-title":"Med J Islam Repub Iran"},{"key":"R14-13-20241021","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s13566-019-00378-y","article-title":"Rectal wall delineation in patients with a rectal displacement device in place during prostate cancer radiotherapy","volume":"8","author":"Ghaffari","year":"2019","journal-title":"J Radiat Oncol"},{"key":"R15-13-20241021","doi-asserted-by":"crossref","first-page":"S123","DOI":"10.1016\/j.ijrobp.2009.03.078","article-title":"Radiation dose-volume effects in radiation-induced rectal injury","volume":"76","author":"Michalski","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R16-13-20241021","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.ijrobp.2006.06.010","article-title":"Use of benchmark dose-volume histograms for selection of the optimal technique between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in prostate cancer","volume":"66","author":"Luo","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R17-13-20241021","doi-asserted-by":"crossref","first-page":"2102","DOI":"10.1002\/ccr3.2430","article-title":"Application of rectal retractor for postprostatectomy salvage radiotherapy of prostate cancer: A case report and literature review","volume":"7","author":"Ghaffari","year":"2019","journal-title":"Clin Case Rep"},{"key":"R18-13-20241021","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1007\/s11547-019-01054-4","article-title":"Is there a role for hydrogel spacer in post-prostatectomy radiotherapy setting?","volume":"124","author":"Ghaffari","year":"2019","journal-title":"Radiol Med"},{"key":"R19-13-20241021","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.ijrobp.2005.10.002","article-title":"Localized volume effects for late rectal and anal toxicity after radiotherapy for prostate cancer","volume":"64","author":"Peeters","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R20-13-20241021","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.ijrobp.2005.05.010","article-title":"Rectal wall sparing effect of three different endorectal balloons in 3D conformal and IMRT prostate radiotherapy","volume":"63","author":"van Lin","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R21-13-20241021","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1016\/j.radonc.2011.09.005","article-title":"Application of a spacer gel to optimize three-dimensional conformal and intensity modulated radiotherapy for prostate cancer","volume":"100","author":"Pinkawa","year":"2011","journal-title":"Radiother Oncol"},{"key":"R22-13-20241021","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.ijrobp.2012.12.019","article-title":"A multi-institutional clinical trial of rectal dose reduction via injected polyethylene-glycol hydrogel during intensity modulated radiation therapy for prostate cancer: Analysis of dosimetric outcomes","volume":"87","author":"Song","year":"2013","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R23-13-20241021","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/S0360-3016(01)01821-1","article-title":"The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer","volume":"52","author":"Wachter","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R24-13-20241021","doi-asserted-by":"crossref","first-page":"7995","DOI":"10.1088\/0031-9155\/58\/22\/7995","article-title":"Effect of endorectal balloon positioning errors on target deformation and dosimetric quality during prostate SBRT","volume":"58","author":"Jones","year":"2013","journal-title":"Phys Med Biol"},{"key":"R25-13-20241021","doi-asserted-by":"crossref","first-page":"834","DOI":"10.3109\/0284186X.2015.1128118","article-title":"Impact of hydrogel spacer injections on interfraction prostate motion during prostate cancer radiotherapy","volume":"55","author":"Picardi","year":"2016","journal-title":"Acta Oncol"},{"key":"R26-13-20241021","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.meddos.2017.07.002","article-title":"Dosimetric comparison of rectal-sparing capabilities of rectal balloon vs. injectable spacer gel in stereotactic body radiation therapy for prostate cancer: Lessons learned from prospective trials","volume":"42","author":"Jones","year":"2017","journal-title":"Med Dosim"},{"key":"R27-13-20241021","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1186\/s13014-019-1248-6","article-title":"Rectum-spacer related acute toxicity \u2013 Endoscopy results of 403 prostate cancer patients after implantation of gel or balloon spacers","volume":"14","author":"Sch\u00f6rghofer","year":"2019","journal-title":"Radiat Oncol"},{"key":"R29-13-20241021","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.brachy.2017.11.006","article-title":"Placement of an absorbable rectal hydrogel spacer in patients undergoing low-dose-rate brachytherapy with palladium-103","volume":"17","author":"Taggar","year":"2018","journal-title":"Brachytherapy"},{"key":"R31-13-20241021","doi-asserted-by":"crossref","first-page":"E647","DOI":"10.1111\/j.1464-410X.2012.11373.x","article-title":"Application technique: placement of a prostate-rectum spacer in men undergoing prostate radiation therapy","volume":"110","author":"Hatiboglu","year":"2012","journal-title":"BJU Int"},{"key":"R32-13-20241021","doi-asserted-by":"crossref","first-page":"e311","DOI":"10.1016\/j.ijrobp.2012.03.028","article-title":"Intensity modulated proton and photon therapy for early prostate cancer with or without transperineal injection of a polyethylen glycol spacer: A treatment planning comparison study","volume":"84","author":"Weber","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R33-13-20241021","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1002\/acm2.12195","article-title":"Real-time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement","volume":"18","author":"Legge","year":"2017","journal-title":"J Appl Clin Med Phys"},{"key":"R34-13-20241021","doi-asserted-by":"crossref","first-page":"20190056","DOI":"10.1259\/bjr.20190056","article-title":"Reduced motion and improved rectal dosimetry through endorectal immobilization for prostate stereotactic body radiotherapy","volume":"92","author":"de Leon","year":"2019","journal-title":"Br J Radiol"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.JCRT_701_19","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:37:50Z","timestamp":1787067470000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.JCRT_701_19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_701_19","relation":{},"ISSN":["0973-1482"],"issn-type":[{"value":"0973-1482","type":"print"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}