{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T22:31:17Z","timestamp":1789165877058,"version":"build-2803163510"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>To compare the accuracy of nidus delineation using magnetic resonance angiography (MRA) to digital subtraction angiography (DSA) and to evaluate setup accuracy of non-invasive frame SRS treatments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>A prospective observational study of 16 patients who underwent non-invasive frame LINAC-based SRS for brain AVMs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>The nidus was separately delineated using DSA and MRA after co-registration onto CT simulation images and compared with respect to their volume and maximum diameters. During treatment, the setup errors observed in x-, y-, and z-directions were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis:<\/jats:title>\n                    <jats:p>Paired t-test (to compare volume and maximum diameter). Wilcoxon signed-rank test (for setup accuracy).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean volume of nidus contoured in MRA was 4.16 cc compared to 3.11 cc in DSA (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      0.297). The mean maximum diameters using MRA and DSA, respectively, in antro-posterior, cranio- caudal, and transverse diameters were 21.97 cc vs. 19.46 cc (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      0.2380), 6.59 cc vs. 9.63 cc (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      0.161), and 18.87 cc vs. 16.81 cc (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      0.178). But these modalities can potentially misinterpret the nidus volume, warranting caution for use of either modality alone. The mean translational shift observed in the x-, y-, and z-directions were 0.06 mm, 0.13 mm, and 0.13 mm, respectively, when couch was brought to neutral position after clockwise couch rotation and 0.07, 0, and 0, respectively, after counterclockwise couch rotation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This study could not demonstrate any statistically significant differences in nidus delineation between MRA and DSA. Setup accuracy achieved with non-invasive thermoplastic mask-based immobilization is within acceptable limits for SRS.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcrt.jcrt_938_21","type":"journal-article","created":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T17:55:16Z","timestamp":1719510916000},"page":"874-880","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of imaging modalities for the accurate delineation of arteriovenous malformations (AVM) and evaluation of setup accuracy with reference to non-invasive LINAC-based stereotactic radiosurgery (SRS)"],"prefix":"10.4103","volume":"20","author":[{"given":"Anju K.","family":"Sukumaran","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, Regional Cancer Centre, Trivandrum, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajeev K.","family":"Raghavan","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Regional Cancer Centre, Trivandrum, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beela S.","family":"Mathew","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Regional Cancer Centre, Trivandrum, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saju","family":"Bhasi","sequence":"additional","affiliation":[{"name":"Department of Radiation Physisics, Regional Cancer Centre, Trivandrum, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumod M.","family":"Koshi","sequence":"additional","affiliation":[{"name":"Department of Imageology, Regional Cancer Centre, Trivandrum, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KM Jagathnath","family":"Krishna","sequence":"additional","affiliation":[{"name":"Department of Cancer Epidemiology and Bio-Statistics, Regional Cancer Centre, Trivandrum, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,22]]},"reference":[{"key":"R1-20241021","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1136\/jnnp.73.5.547","article-title":"Prevalence of adults with brain arteriovenous malformations: A community based study in Scotland using capture- recapture analysis","volume":"73","author":"Al-Shahi","year":"2002","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"R2-20241021","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.ijrobp.2006.08.075","article-title":"Delineation of brain AVMs on MR-angiography for the purpose of stereotactic radiosurgery","volume":"67","author":"Buis","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R3-20241021","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1227\/00006123-199410000-00002","article-title":"Stereotactic magnetic resonance angiography for targeting in arteriovenous malformation radiosurgery","volume":"35","author":"Kondziolka","year":"1994","journal-title":"Neurosurgery"},{"key":"R4-20241021","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.ijrobp.2011.05.048","article-title":"Clinical evaluation of a robotic 6-degree of freedom treatment couch for frameless radiosurgery","volume":"83","author":"Gevaert","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R5-20241021","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1016\/j.ijrobp.2005.03.039","article-title":"Comparison of imaging modalities for the accurate delineation of arteriovenous malformation, with reference to stereotactic radiosurgery","volume":"62","author":"Aoyama","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R6-20241021","doi-asserted-by":"crossref","first-page":"E3","DOI":"10.3171\/2019.9.FOCUS19627","article-title":"The use of contrast-enhanced, time-resolved magnetic resonance angiography in cerebrovascular pathology","volume":"47","author":"Grossberg","year":"2019","journal-title":"Neurosurg Focus"},{"key":"R7-20241021","doi-asserted-by":"crossref","first-page":"e19814","DOI":"10.5812\/iranjradiol.19814","article-title":"Magnetic resonance angiography in the diagnosis of cerebral arteriovenous malformation and dural arteriovenous fistulas: Comparison of time-resolved magnetic resonance angiography and three dimensional time-of-flight magnetic resonance angiography","volume":"13","author":"Cheng","year":"2016","journal-title":"Iran J Radiol"},{"key":"R8-20241021","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/0360-3016(88)90446-4","article-title":"A system for stereotactic radiosurgery with linear accelerator","volume":"14","author":"Lutz","year":"1988","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R9-20241021","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/S0360-3016(98)00040-6","article-title":"IRLED- based patient localization for LINAC radiosurgery","volume":"41","author":"Meeks","year":"1998","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R10-20241021","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.radonc.2009.12.030","article-title":"A clinical comparison of patient setup and intra-fraction motion using frame-based radiosurgery versus a frameless image-guided radiosurgery system for intracranial lesions","volume":"95","author":"Ramakrishna","year":"2010","journal-title":"Radiother Oncol"},{"key":"R11-20241021","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1002\/acm2.13076","article-title":"A retrospective analysis of setup and intrafraction positional variation in stereotactic radiotherapy treatments","volume":"21","author":"Barnes","year":"2020","journal-title":"J Appl Clin Med Phys"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_938_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:39:01Z","timestamp":1787067541000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcrt.jcrt_938_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,22]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jcrt.jcrt_938_21","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,22]]},"assertion":[{"value":"2021-06-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-04-04","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}