{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:41:42Z","timestamp":1787071302442,"version":"build-2736575974"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Atlantoaxial stabilization is indicated for traumatic or degenerative pathologies. The procedure is technically demanding due to delicate neurovascular anatomy and narrow bone corridors. Recent technologies such as neuronavigation and intraoperative computed tomography (iCT) may improve screw placement and reduce complications. This study reports our experience with C1-C2 stabilization using these tools.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>This retrospective single-center study included 15 consecutive patients who underwent C1-C2 stabilization. Clinical assessment was performed pre- and postoperatively using the Neck Disability Index and American Spinal Injury Association score. Fractures were classified using standard parameters; degenerative cases were assessed with positional magnetic resonance imaging. Other data collected included pathology, surgical technique, sagittal\/coronal alignment, complications, and follow-up duration. All surgeries used iCT for navigation and intraoperative control. Screw accuracy was assessed with a modified Gertzbein-Robbins scale.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Mean patient age was 63 years. Indications were traumatic (47%) or degenerative (53%). Screws were placed into C1-C2 lateral masses. Of 60 screws, 54 were grade A and 6 were grade B. One case required recalibration due to neuronavigation inaccuracy. Alignment was restored in all cases. Thirteen patients showed significant clinical improvement. Mean follow-up was 12 months, with no complications recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Neuronavigation with iCT for C1-C2 screw placement proved safe and accurate. Our data show 90% grade A and 10% grade B screws, with a mean deviation of 0.13 mm and no intra-or postoperative complications attributable to the technique.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcvjs.jcvjs_148_25","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T13:01:55Z","timestamp":1763643715000},"page":"417-422","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Intraoperative computed tomography guided navigation for atlantoaxial screw placement: Accuracy and safety analysis"],"prefix":"10.4103","volume":"16","author":[{"given":"Mario","family":"Giordano","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, International Neuroscience Institute, Hanover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Iaccarino","sequence":"additional","affiliation":[{"name":"Department of Biomedical, Metabolic and Neurosciences, School of Neurosurgery, University of Modena and Reggio Emilia, Modena, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamah","family":"Almarzooq","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, International Neuroscience Institute, Hanover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir Kaywan","family":"Aftahy","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, International Neuroscience Institute, Hanover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrike","family":"Kabelitz","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, International Neuroscience Institute, Hanover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madjid","family":"Samii","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, International Neuroscience Institute, Hanover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Samii","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, International Neuroscience Institute, Hanover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,11,20]]},"reference":[{"key":"R1-20260421","doi-asserted-by":"crossref","first-page":"175","DOI":"10.4103\/jcvjs.jcvjs_22_22","article-title":"An experience with Goel-Harms C1-C2 fixation for type II odontoid fractures","volume":"13","author":"Jain","year":"2022","journal-title":"J Craniovertebr Junction Spine"},{"key":"R2-20260421","doi-asserted-by":"crossref","first-page":"368","DOI":"10.4103\/jcvjs.jcvjs_128_22","article-title":"C2 screw fixation techniques in atlantoaxial instability: A technical review","volume":"13","author":"Singh","year":"2022","journal-title":"J Craniovertebr Junction Spine"},{"key":"R3-20260421","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1055\/s-0041-1722838","article-title":"Atlantoaxial stabilization by posterior C1 and C2 screw-rod fixation for various pathologies: Case series and comprehensive review of literature","volume":"12","author":"Unni","year":"2021","journal-title":"J Neurosci Rural Pract"},{"key":"R4-20260421","first-page":"100224","article-title":"Management of combined atlas and axis fractures: A systematic review","volume":"14","author":"Mohile","year":"2023","journal-title":"N Am Spine Soc J"},{"key":"R5-20260421","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1007\/s10143-020-01345-9","article-title":"Atlanto-axial rotary instability (fielding type 1): Characteristic clinical and radiological findings, and treatment outcomes following alignment, fusion, and stabilization","volume":"44","author":"Henderson","year":"2021","journal-title":"Neurosurg Rev"},{"key":"R6-20260421","first-page":"89","article-title":"Dynamic MRI in the evaluation of the spine: State of the art","volume":"89","author":"Michelini","year":"2018","journal-title":"Acta Biomed"},{"key":"R7-20260421","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1007\/s00586-015-3814-4","article-title":"Accuracy and workflow of navigated spinal instrumentation with the mobile AIRO(\u00ae) CT scanner","volume":"25","author":"Hecht","year":"2016","journal-title":"Eur Spine J"},{"key":"R8-20260421","first-page":"e1887","article-title":"Improving C1-C2 complex fusion rates: An alternate approach","volume":"9","author":"Ghostine","year":"2017","journal-title":"Cureus"},{"key":"R9-20260421","doi-asserted-by":"crossref","first-page":"e938600","DOI":"10.12659\/MSM.938600","article-title":"Management of unstable C1 fractures involving the lateral mass: Posterior C1-C2 screw-rod fixation and fusion","volume":"29","author":"Zou","year":"2023","journal-title":"Med Sci Monit"},{"key":"R10-20260421","doi-asserted-by":"crossref","first-page":"94","DOI":"10.4103\/sni.sni_10_18","article-title":"New technique for C1-C2 fixation","volume":"9","author":"Harati","year":"2018","journal-title":"Surg Neurol Int"},{"key":"R11-20260421","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1186\/s13018-018-0985-9","article-title":"Radiographic and clinical outcomes of C1-C2 intra-articular screw fixation in patients with atlantoaxial subluxation","volume":"13","author":"Uei","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R12-20260421","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1186\/s12891-020-03273-7","article-title":"Surgical treatment of atlantoaxial subluxation by intraoperative skull traction and C1-C2 fixation","volume":"21","author":"Guo","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"R13-20260421","doi-asserted-by":"crossref","first-page":"2031","DOI":"10.1111\/os.12792","article-title":"Transarticular screw fixation in the treatment of severe C1-C2 dislocation: A case series report","volume":"12","author":"Du","year":"2020","journal-title":"Orthop Surg"},{"key":"R14-20260421","first-page":"353","article-title":"Comparison of two treatments for atlantoaxial instability injury: C1\u2013C2 transarticular screw fixation versus C1 lateral mass-C2 pedicle screw fixation","volume":"174","author":"Gia Du","year":"2023","journal-title":"Clin Ter"},{"key":"R15-20260421","doi-asserted-by":"crossref","first-page":"114","DOI":"10.3390\/medicina58010114","article-title":"Fluoroscopy-assisted C1-C2 posterior fixation for atlantoaxial instability: A single-center case series of 78 patients","volume":"58","author":"Tatter","year":"2022","journal-title":"Medicina (Kaunas)"},{"key":"R16-20260421","doi-asserted-by":"crossref","first-page":"559","DOI":"10.31616\/asj.2022.0182","article-title":"Atlantoaxial stabilization using C1 lateral mass and C2 pedicle\/translaminar screw fixation by intraoperative C1- and C2-direct-captured navigation with preoperative computed tomography images","volume":"17","author":"Itoh","year":"2023","journal-title":"Asian Spine J"},{"key":"R17-20260421","doi-asserted-by":"crossref","first-page":"149","DOI":"10.25259\/SNI_340_2019","article-title":"Intraoperative imaging and navigation for C1-C2 posterior fusion","volume":"10","author":"Harel","year":"2019","journal-title":"Surg Neurol Int"},{"key":"R18-20260421","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1055\/s-0035-1563723","article-title":"Screw placement accuracy and outcomes following O-arm-navigated atlantoaxial fusion: A feasibility study","volume":"6","author":"Smith","year":"2016","journal-title":"Global Spine J"}],"container-title":["Journal of Craniovertebral Junction and Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcvjs.jcvjs_148_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:44:20Z","timestamp":1787067860000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcvjs.jcvjs_148_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcvjs.jcvjs_148_25","relation":{},"ISSN":["0974-8237","0976-9285"],"issn-type":[{"value":"0974-8237","type":"print"},{"value":"0976-9285","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"2025-07-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}