{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:31:36Z","timestamp":1786649496955,"version":"build-2736575974"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>The susceptibility of the thoracolumbar junction to injury is attributed mainly to the transition from a relatively rigid thoracic kyphosis to a more mobile lumbar lordosis that occurs at thoracic T11 to lumbar L2 level.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>We present our experience of management of 87 patients of single-level injury who presented with or without neurological deficit between March 2014 and October 2018. All adult patients (18\u201359 years) were included who were selected for management by single-level posterior transpedicular fixation and followed up for a minimum of 12 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The male-to-female ratio in our study was 6.3:1 with a mean age of 32 years. Forty-eight percent were in the work-productive age group of 31\u201340 years. The L1 vertebra was the most commonly fractured (47%) followed by D12, L2, and D11 vertebra, respectively. Thoracolumbar injury classification severity score 6 was the most common score at presentation. More than 80% patients had some degree of neurological deficit on American Spinal Injuries Association grading with Grade C being the most common pattern of presentation of spinal cord neurological deficit. About 25% patients had some degree of neurological improvement at 12 months follow-up. Among them, 10% achieved an ambulatory status from a bed-ridden status signifying the importance of surgical management in appropriately selected patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Single-level transpedicular fixation can be offered to a group of selected patients for rehabilitative purposes. This is the largest study discussing only junctional thoracolumbar injuries and also outcomes in single-level posterior instrumentation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcvjs.jcvjs_153_24","type":"journal-article","created":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T05:11:22Z","timestamp":1743657082000},"page":"77-80","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Outcome characteristics of surgical management of single-level junctional thoracolumbar fractures by short segment posterior transpedicular fixation in selected patients"],"prefix":"10.4103","volume":"16","author":[{"given":"Sajad Hussain","family":"Arif","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khurram","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohsin","family":"Fayaz","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abrar Ahad","family":"Wani","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarabjit Singh","family":"Chibber","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nayil Khursheed","family":"Malik","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zulfikar","family":"Ali","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Sher-i-Kashmir Institute of Medical Sciences, Soura, Srinagar, Jammu and Kashmir, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,1]]},"reference":[{"key":"R1-20250401","doi-asserted-by":"crossref","first-page":"713","DOI":"10.14245\/ns.2142390.195","article-title":"Indications for nonsurgical treatment of thoracolumbar spine fractures: WFNS spine committee recommendations","volume":"18","author":"Peev","year":"2021","journal-title":"Neurospine"},{"key":"R2-20250401","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/S0020-1383(98)00173-9","article-title":"Steffee variable screw placement system in the management of unstable thoracolumbar fractures: A third world experience","volume":"29","author":"Chadha","year":"1998","journal-title":"Injury"},{"key":"R3-20250401","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1038\/sj.sc.3100765","article-title":"Results of spinal cord decompression and thoracolumbar pedicle stabilisation in relation to the time of operation","volume":"37","author":"Gaebler","year":"1999","journal-title":"Spinal Cord"},{"key":"R4-20250401","doi-asserted-by":"crossref","first-page":"72","DOI":"10.4103\/0019-5413.143914","article-title":"Management of thoracolumbar spine trauma: An overview","volume":"49","author":"Rajasekaran","year":"2015","journal-title":"Indian J Orthop"},{"key":"R5-20250401","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1007\/s005860050212","article-title":"Short segment fixation of thoracolumbar burst fractures without fusion","volume":"8","author":"Sanderson","year":"1999","journal-title":"Eur Spine J"},{"key":"R6-20250401","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.jor.2016.06.019","article-title":"The epidemiology of thoracolumbar trauma: A meta-analysis","volume":"13","author":"Katsuura","year":"2016","journal-title":"J Orthop"},{"key":"R7-20250401","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1038\/sc.2012.45","article-title":"Demographic profile of traumatic spinal cord injuries admitted at Indian spinal injuries centre with special emphasis on mode of injury: A retrospective study","volume":"50","author":"Chhabra","year":"2012","journal-title":"Spinal Cord"},{"key":"R8-20250401","doi-asserted-by":"crossref","first-page":"S84","DOI":"10.1097\/00007632-199103001-00014","article-title":"Biomechanics of thoracolumbar spinal fixation","volume":"16","author":"Krag","year":"1991","journal-title":"A review. Spine (Phila Pa 1976)"},{"key":"R9-20250401","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1007\/s00586-007-0310-5","article-title":"Treatment of unstable thoracolumbar junction burst fractures with short- or long-segment posterior fixation in magerl type a fractures","volume":"16","author":"Altay","year":"2007","journal-title":"Eur Spine J"},{"key":"R10-20250401","first-page":"19","article-title":"Short same-segment fixation of thoracolumbar burst fractures","volume":"71","author":"Eno","year":"2012","journal-title":"Hawaii J Med Public Health"},{"key":"R11-20250401","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/BSD.0b013e3181af20b6","article-title":"Successful treatment of thoracolumbar fractures with short-segment pedicle instrumentation","volume":"23","author":"Gelb","year":"2010","journal-title":"J Spinal Disord Tech"},{"key":"R12-20250401","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1097\/BRS.0b013e318067dd24","article-title":"Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture","volume":"32","author":"Mahar","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R13-20250401","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/BSD.0b013e3181870385","article-title":"The use of screw at the fracture level in the treatment of thoracolumbar burst fractures","volume":"22","author":"Guven","year":"2009","journal-title":"J Spinal Disord Tech"},{"key":"R14-20250401","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.ijsp.2012.09.002","article-title":"Pedicle screw instrumentation of thoracolumbar burst fractures: Biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture","volume":"6","author":"Bolesta","year":"2012","journal-title":"Int J Spine Surg"}],"container-title":["Journal of Craniovertebral Junction and Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcvjs.jcvjs_153_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:54:49Z","timestamp":1786647289000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcvjs.jcvjs_153_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcvjs.jcvjs_153_24","relation":{},"ISSN":["0974-8237","0976-9285"],"issn-type":[{"value":"0974-8237","type":"print"},{"value":"0976-9285","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2024-10-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}