{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:41:43Z","timestamp":1787071303751,"version":"build-2736575974"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>While C1 screws provide an additional fixation point in occipitocervical (OC) fusion, they are often skipped due to surgical feasibility. In patients undergoing OC fusion with atlantooccipital dissociation (AOD), we sought to evaluate the impact of skipping C1 screws on: (1) construct length, (2) perioperative outcomes, and (3) long-term outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A retrospective cohort study was performed for patients with traumatic cervical injury with AOD requiring OC fusion from 2003 to 2022. The primary outcome was total levels of fusion. Perioperative outcomes included operative time, estimated blood loss, and postoperative infections. Long-term outcomes included mechanical complications and reoperation. Bivariate and multivariable linear regression controlling for age, sex, and body mass index was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Ninety-two patients underwent OC fusion with AOD (mean age: 40.2 \u00b1 17.2 years) with a median follow-up of 0.9 (interquartile range: 0.4\u20132.8) years, and 54 (58.7%) received C1 instrumentation. Instrumenting C1 led to decreased fusion levels (2.5 \u00b1 0.8 vs. 3.8 \u00b1 1.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001) but increased operative time (192.7 \u00b1 68.8 vs. 166.3 \u00b1 40.5 min,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.032), blood loss (369.8 \u00b1 424.8 vs. 167.0 \u00b1 95.8 ml,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002), and postoperative infections (11.1% vs. 0.0%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.040). There was no difference in mechanical complications (1.9% vs. 2.6%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 1.000) or reoperation (5.6% vs. 7.9%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.688). Mechanical complications were screw loosening (50.0%), instrumentation failure (50.0%), and pseudarthrosis (50.0%). On multivariable linear regression, C1 instrumentation was independently associated with decreased levels fused (\u03b2 = \u2212-1.06, 95% confidence interval = \u2212-1.56 \u2013 -0.67,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In OC fusion for cervical trauma, 41% of patients did not receive C1 screws. Skipping C1 was associated with longer constructs but reduced operative time, blood loss, and infection, without affecting complication or reoperation rates, highlighting the trade-offs of skipping C1 fixation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jcvjs.jcvjs_155_25","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T13:01:59Z","timestamp":1763643719000},"page":"458-464","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Are C1 screws needed in occipitocervical fusion for traumatic cervical spine injury?"],"prefix":"10.4103","volume":"16","author":[{"given":"Tyler","family":"Zeoli","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harsh","family":"Jain","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nick De","family":"Oliviera","sequence":"additional","affiliation":[{"name":"Vanderbilt University School of Medicine, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emma","family":"Ye","sequence":"additional","affiliation":[{"name":"Vanderbilt University School of Medicine, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranbir","family":"Ahluwalia","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iyan","family":"Younus","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir M.","family":"Abtahi","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"},{"name":"Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byron F.","family":"Stephens","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"},{"name":"Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott L.","family":"Zuckerman","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"},{"name":"Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,11,20]]},"reference":[{"key":"R1-20260421","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1097\/JS9.0000000000000365","article-title":"Prognosis and conditional nomogram of cervical spine fracture in patients with severe spinal cord injury: A multicenter retrospective study","volume":"109","author":"Huang","year":"2023","journal-title":"Int J Surg"},{"key":"R2-20260421","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/j.spinee.2011.01.029","article-title":"Epidemiology of cervical spine fractures in the US military","volume":"12","author":"Schoenfeld","year":"2012","journal-title":"Spine J"},{"key":"R3-20260421","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.ajme.2011.07.007","article-title":"Occipitocervical fixation in the management of craniocervical instabilities","volume":"47","author":"Zidan","year":"2011","journal-title":"Alexandria J Med"},{"key":"R4-20260421","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s12178-016-9347-6","article-title":"Occipitocervical dissociation-incidence, evaluation, and treatment","volume":"9","author":"Kasliwal","year":"2016","journal-title":"Curr Rev Musculoskelet Med"},{"key":"R5-20260421","doi-asserted-by":"crossref","first-page":"148","DOI":"10.4103\/jcvjs.JCVJS_72_18","article-title":"Management of occipitocervical junction and upper cervical trauma","volume":"9","author":"Dagtekin","year":"2018","journal-title":"J Craniovertebr Junction Spine"},{"key":"R6-20260421","doi-asserted-by":"crossref","first-page":"388","DOI":"10.3171\/2009.5.SPINE08866","article-title":"Occipital condyle fractures: clinical decision rule and surgical management","volume":"11","author":"Maserati","year":"2009","journal-title":"J Neurosurg Spine"},{"key":"R7-20260421","doi-asserted-by":"crossref","first-page":"100783","DOI":"10.1016\/j.semss.2019.100783","article-title":"Occipitocervical fusion: A review and current concepts","volume":"32","author":"Shasti","year":"2020","journal-title":"Semin Spine Surg"},{"key":"R8-20260421","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1016\/j.wneu.2024.09.128","article-title":"Recent global trends and hotspots in occipitocervical fusion: A bibliometric analysis and visualization study","volume":"193","author":"Gorbacheva","year":"2025","journal-title":"World Neurosurg"},{"issue":"Suppl 6","key":"R9-20260421","doi-asserted-by":"crossref","first-page":"S900","DOI":"10.1007\/s00586-013-3015-y","article-title":"Occipito-cervical fusion in post-traumatic instability of the upper cervical spine and cranio-cervical junction","volume":"22","author":"Cappuccio","year":"2013","journal-title":"Eur Spine J"},{"key":"R10-20260421","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF01400872","article-title":"Plate and screw fixation for atlanto-axial subluxation","volume":"129","author":"Goel","year":"1994","journal-title":"Acta Neurochir (Wien)"},{"key":"R11-20260421","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1097\/BRS.0000000000000611","article-title":"C1 lateral mass screw placement in occipitalization with atlantoaxial dislocation and basilar invagination: A report of 146 cases","volume":"39","author":"Yin","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"key":"R12-20260421","doi-asserted-by":"crossref","first-page":"298","DOI":"10.31616\/asj.2019.0199","article-title":"Computed Tomography-based feasibility study of C1 posterior arch crisscrossing screw fixation","volume":"14","author":"Sangondimath","year":"2020","journal-title":"Asian Spine J"},{"key":"R13-20260421","doi-asserted-by":"crossref","first-page":"145","DOI":"10.21037\/jss.2019.12.01","article-title":"Occipital fixation techniques and complications","volume":"6","author":"Macki","year":"2020","journal-title":"J Spine Surg"},{"key":"R14-20260421","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1186\/s13018-020-01609-6","article-title":"Biomechanical study of C1 posterior arch crossing screw and C2 lamina screw fixations for atlantoaxial joint instability","volume":"15","author":"Liu","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R15-20260421","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1177\/2192568219877878","article-title":"Occipitocervical fixation: General considerations and surgical technique","volume":"10","author":"Joaquim","year":"2020","journal-title":"Global Spine J"},{"key":"R16-20260421","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1093\/ons\/opz068","article-title":"Analysis of risk factors for posterior C1 screw-related complication: A retrospective study of 358 posterior C1 screws","volume":"17","author":"Yi","year":"2019","journal-title":"Oper Neurosurg"},{"key":"R17-20260421","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R18-20260421","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.wneu.2011.10.035","article-title":"C2 nerve root sectioning in posterior atlantoaxial instrumented fusions: A structured review of literature","volume":"78","author":"Elliott","year":"2012","journal-title":"World Neurosurg"},{"key":"R19-20260421","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.otsr.2013.09.019","article-title":"C1-C2 stabilization by Harms arthrodesis: Indications, technique, complications and outcomes in a prospective 26-case series","volume":"100","author":"Bourdillon","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"R20-20260421","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/j.spinee.2013.04.006","article-title":"Postoperative occipital neuralgia with and without C2 nerve root transection during atlantoaxial screw fixation: A post-hoc comparative outcome study of prospectively collected data","volume":"13","author":"Yeom","year":"2013","journal-title":"Spine J"},{"key":"R21-20260421","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.wneu.2016.10.007","article-title":"Detethering of the C2 nerve root and avoidance of transection and injury during C1 screw placement: A cadaveric feasibility study","volume":"97","author":"Fisahn","year":"2017","journal-title":"World Neurosurg"},{"key":"R22-20260421","doi-asserted-by":"crossref","first-page":"e579","DOI":"10.1016\/j.wneu.2018.02.100","article-title":"The ponticulus posticus as risk factor for screw insertion into the first cervical lateral mass","volume":"113","author":"Arslan","year":"2018","journal-title":"World Neurosurg"},{"key":"R23-20260421","doi-asserted-by":"crossref","first-page":"420","DOI":"10.7887\/jcns.22.420","article-title":"Clinical and biomechanical considerations in occipitocervical fusion","volume":"22","author":"Wolfla","year":"2013","journal-title":"Jpn J Neurosurg"},{"key":"R24-20260421","doi-asserted-by":"crossref","first-page":"296","DOI":"10.3171\/SPI\/2008\/9\/9\/296","article-title":"The cervical end of an occipitocervical fusion: A biomechanical evaluation of 3 constructs. Laboratory investigation","volume":"9","author":"Finn","year":"2008","journal-title":"J Neurosurg Spine"},{"key":"R25-20260421","doi-asserted-by":"crossref","first-page":"236","DOI":"10.5312\/wjo.v6.i2.236","article-title":"Atlanto-occipital dislocation","volume":"6","author":"Hall","year":"2015","journal-title":"World J Orthop"},{"key":"R26-20260421","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1055\/s-0034-1543967","article-title":"Occipitocervical fusion surgery: Review of operative techniques and results","volume":"76","author":"Kukreja","year":"2015","journal-title":"J Neurol Surg B Skull Base"},{"key":"R27-20260421","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/s13018-025-05472-1","article-title":"Superior biomechanical stability of pedicle screws compared to lateral mass screws: Recommendations for bicortical positioning and enhancing bone contact in geriatric C1 vertebrae","volume":"20","author":"Leonhardt","year":"2025","journal-title":"J Orthop Surg Res"},{"key":"R28-20260421","doi-asserted-by":"crossref","first-page":"151","DOI":"10.3171\/2014.10.SPINE13805","article-title":"Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: A systematic review and meta-analysis","volume":"22","author":"Du","year":"2015","journal-title":"J Neurosurg Spine"},{"key":"R29-20260421","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1186\/s13018-023-03838-x","article-title":"Fixation-induced surgical segment\u2019s high stiffness and the damage of posterior structures together trigger a higher risk of adjacent segment disease in patients with lumbar interbody fusion operations","volume":"18","author":"Cai","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R31-20260421","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1177\/2192568217719436","article-title":"Patterns of cervical disc degeneration: Analysis of magnetic resonance imaging of over 1000 symptomatic subjects","volume":"8","author":"Suzuki","year":"2018","journal-title":"Global Spine J"},{"key":"R32-20260421","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1007\/s00586-021-07037-2","article-title":"Complications of occipitocervical fixation: Retrospective review of 128 patients with 5-year mean follow-up","volume":"31","author":"Zileli","year":"2022","journal-title":"Eur Spine J"},{"key":"R33-20260421","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1227\/01.NEU.0000365804.75511.E2","article-title":"C1 lateral mass fixation: A comparison of constructs","volume":"66","author":"Mummaneni","year":"2010","journal-title":"Neurosurgery"},{"key":"R34-20260421","doi-asserted-by":"crossref","first-page":"e459","DOI":"10.1016\/j.wneu.2018.07.182","article-title":"C1-C2 Fusion Versus Occipito-Cervical Fusion for High Cervical Fractures: A Multi-Institutional Database Analysis and Review of the Literature","volume":"119","author":"Bhimani","year":"2018","journal-title":"World Neurosurg"},{"key":"R35-20260421","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.jocn.2017.04.026","article-title":"Factors associated with prolonged ventilation and reintubation in adult spinal deformity surgery","volume":"43","author":"De la Garza Ramos","year":"2017","journal-title":"J Clin Neurosci"},{"key":"R36-20260421","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.jocn.2017.04.026","article-title":"Factors associated with prolonged ventilation and reintubation in adult spinal deformity surgery","volume":"43","author":"De la Garza Ramos","year":"2017","journal-title":"J Clin Neurosci"},{"key":"R37-20260421","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00264-011-1426-0","article-title":"Infections in spinal instrumentation","volume":"36","author":"Gerometta","year":"2012","journal-title":"Int Orthop"},{"key":"R38-20260421","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1186\/s13018-023-04422-z","article-title":"Different cervical vertebral bone quality scores for bone mineral density assessment for the patients with cervical degenerative disease undergoing ACCF\/ACDF: Computed tomography and magnetic resonance imaging-based study","volume":"18","author":"Wang","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R39-20260421","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1097\/JS9.0000000000002027","article-title":"Adverse complications of cervical spinal fusion in patients with different types of diabetes mellitus: A retrospective nationwide inpatient sample database cross-sectional study","volume":"111","author":"Liao","year":"2025","journal-title":"Int J Surg"},{"key":"R40-20260421","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s12178-022-09814-y","article-title":"The effect of diabetes and metabolic syndrome on spine surgery outcomes","volume":"16","author":"Bajaj","year":"2023","journal-title":"Curr Rev Musculoskelet Med"},{"key":"R41-20260421","doi-asserted-by":"crossref","first-page":"52S","DOI":"10.1177\/21925682231159066","article-title":"Avoiding spinal implant failures in osteoporotic patients: A narrative review","volume":"13","author":"Sch\u00f6mig","year":"2023","journal-title":"Global Spine J"}],"container-title":["Journal of Craniovertebral Junction and Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jcvjs.jcvjs_155_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:44:21Z","timestamp":1787067861000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jcvjs.jcvjs_155_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":40,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jcvjs.jcvjs_155_25","relation":{},"ISSN":["0974-8237","0976-9285"],"issn-type":[{"value":"0974-8237","type":"print"},{"value":"0976-9285","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"2025-07-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}