{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:29:48Z","timestamp":1786649388827,"version":"build-2736575974"},"reference-count":53,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:p>Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an invented method to facilitate a minimally invasive occlusion of the aorta to stop a life-threatening hemorrhage. This review described an established pathway for noncompressible exsanguination (REBOA procedures) in trauma patients at a Level 1 trauma center. A detailed description starting from the structural changes of the hospital and facilities itself, the initial thoughts, implementation of the process, and continuous revision and improvement of guidelines were discussed. A multidisciplinary core team consisting of trauma surgeons, anesthesiologists, interventional radiologists, and operating room (OR) staff developed step-by-step clinical practice guidelines for using REBOA at our trauma center. A comprehensive training program for specialized procedural training was implemented to ensure the competency of all relevant medical personnel in managing trauma patients. The REBOA guidelines underwent plan-do-check-act quality cycle improvement until the latest guidelines were reached with each use of REBOA in a trauma patient, leading to further auditing of the guidelines to identify areas for improvement. The current review discusses the critical role of adopting innovative technologies and adapting protocols in trauma care, particularly for vulnerable patients with a high risk of morbidity and mortality. Continuous process improvement, procedural refinement, and evolving guidelines are essential prerequisites for optimizing patient outcomes. We described a valuable framework for other trauma programs to implement and adapt similar endovascular bleeding control approaches, thereby potentially enhancing patient care.<\/jats:p>","DOI":"10.4103\/jets.jets_79_24","type":"journal-article","created":{"date-parts":[[2025,2,10]],"date-time":"2025-02-10T05:00:08Z","timestamp":1739163608000},"page":"32-40","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Implementation and Adaptation of Pathway of Resuscitative Endovascular Balloon Occlusion of the Aorta after Traumatic Injury"],"prefix":"10.4103","volume":"18","author":[{"given":"Ammar","family":"Al-Hassani","sequence":"first","affiliation":[{"name":"Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bianca M.","family":"Wahlen","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayman","family":"El-Menyar","sequence":"additional","affiliation":[{"name":"Department of Surgery, Trauma and Vascular Surgery, Clinical Research, Hamad Medical Corporation, Doha, Qatar"},{"name":"Department of Clinical Medicine, Weill Cornell Medicine, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ibrahim","family":"Al-Hassani","sequence":"additional","affiliation":[{"name":"Pre-Graduate Student, Weill Cornell Medicine, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naushad A.","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Surgery, Trauma and Vascular Surgery, Clinical Research, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sagar","family":"Galwankar","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Sarasota Memorial Hospital, Florida State University, Sarasota, Florida, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandro","family":"Rizoli","sequence":"additional","affiliation":[{"name":"Department of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Al-Thani","sequence":"additional","affiliation":[{"name":"Department of Surgery, Trauma and Vascular Surgery, Hamad Medical Corporation, Doha, Qatar"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,10]]},"reference":[{"key":"R1-20260422","doi-asserted-by":"crossref","DOI":"10.1007\/s00068-023-02422-6","article-title":"Can \u201cStop The Bleed\u201d training courses for laypersons improve hemorrhage control knowledge, skills, and attitudes? A systematic review","author":"Consunji","year":"2024","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R2-20260422","first-page":"S3","article-title":"Impact of hemorrhage on trauma outcome: An overview of epidemiology, clinical presentations, and therapeutic considerations","volume":"60","author":"Kauvar","year":"2006","journal-title":"J Trauma"},{"key":"R3-20260422","doi-asserted-by":"crossref","first-page":"121432.","DOI":"10.1016\/j.biomaterials.2022.121432","article-title":"A review of treatments for non-compressible torso hemorrhage (NCTH) and internal bleeding","volume":"283","author":"Hong","year":"2022","journal-title":"Biomaterials"},{"key":"R4-20260422","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.cjtee.2021.03.005","article-title":"Management of non-compressible torso hemorrhage: An update","volume":"24","author":"Zhang","year":"2021","journal-title":"Chin J Traumatol"},{"key":"R5-20260422","doi-asserted-by":"crossref","first-page":"S236","DOI":"10.1097\/TA.0000000000000770","article-title":"Resuscitative endovascular balloon occlusion of the aorta for hemorrhage control: Past, present, and future","volume":"79","author":"Belenkiy","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"key":"R6-20260422","doi-asserted-by":"crossref","first-page":"400.","DOI":"10.1186\/s13054-016-1577-x","article-title":"Resuscitative endovascular balloon occlusion of the aorta versus aortic cross clamping among patients with critical trauma: A nationwide cohort study in Japan","volume":"20","author":"Abe","year":"2016","journal-title":"Crit Care"},{"key":"R7-20260422","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/TA.0000000000000648","article-title":"An evidence-based approach to patient selection for emergency department thoracotomy: A practice management guideline from the Eastern Association for the Surgery of Trauma","volume":"79","author":"Seamon","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"key":"R8-20260422","doi-asserted-by":"crossref","first-page":"30.","DOI":"10.1186\/s13017-017-0142-5","article-title":"A meta-analysis of Resuscitative endovascular balloon occlusion of the aorta (REBOA) or open aortic cross-clamping by resuscitative thoracotomy in non-compressible torso hemorrhage patients","volume":"12","author":"Manzano Nunez","year":"2017","journal-title":"World J Emerg Surg"},{"key":"R9-20260422","doi-asserted-by":"crossref","first-page":"S128","DOI":"10.1097\/TA.0000000000001104","article-title":"Identifying potential utility of resuscitative endovascular balloon occlusion of the aorta: An autopsy study","volume":"81","author":"Joseph","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"key":"R10-20260422","first-page":"563","article-title":"Resuscitative endovascular balloon occlusion of the aorta: Promise, practice, and progress?","volume":"22","author":"Perkins","year":"2016","journal-title":"Curr Opin Crit Care"},{"key":"R11-20260422","doi-asserted-by":"crossref","first-page":"108","DOI":"10.5090\/jcs.22.105","article-title":"Feasibility and clinical outcomes of resuscitative endovascular balloon occlusion of the aorta in patients with traumatic shock: A single-center 5-year experience","volume":"56","author":"Lee","year":"2023","journal-title":"J Chest Surg"},{"key":"R12-20260422","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/TA.0000000000001079","article-title":"The AAST prospective Aortic occlusion for resuscitation in trauma and acute care surgery (AORTA) registry: Data on contemporary utilization and outcomes of aortic occlusion and resuscitative balloon occlusion of the aorta (REBOA)","volume":"81","author":"DuBose","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"key":"R13-20260422","doi-asserted-by":"crossref","first-page":"2126","DOI":"10.1016\/j.injury.2022.03.005","article-title":"Survival benefit for pelvic trauma patients undergoing resuscitative endovascular balloon occlusion of the aorta: Results of the AAST Aortic occlusion for resuscitation in trauma acute care surgery (AORTA) registry","volume":"53","author":"Bini","year":"2022","journal-title":"Injury"},{"key":"R14-20260422","first-page":"1869","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct for hemorrhagic shock","volume":"71","author":"Stannard","year":"2011","journal-title":"J Trauma"},{"key":"R15-20260422","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.jamcollsurg.2018.01.044","article-title":"Resuscitative endovascular balloon occlusion of the aorta and resuscitative thoracotomy in select patients with hemorrhagic shock: Early results from the American association for the surgery of trauma\u2019s aortic occlusion in resuscitation for trauma and acute care surgery registry","volume":"226","author":"Brenner","year":"2018","journal-title":"J Am Coll Surg"},{"key":"R16-20260422","doi-asserted-by":"crossref","first-page":"3561","DOI":"10.1007\/s00068-022-01955-6","article-title":"Impact of Resuscitative endovascular balloon occlusion of the aorta (REBOA) in traumatic abdominal and pelvic exsanguination: A systematic review and meta-analysis","volume":"48","author":"Granieri","year":"2022","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R17-20260422","doi-asserted-by":"crossref","first-page":"41.","DOI":"10.1186\/s13017-021-00386-9","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA) in patients with major trauma and uncontrolled haemorrhagic shock: A systematic review with meta-analysis","volume":"16","author":"Castellini","year":"2021","journal-title":"World J Emerg Surg"},{"key":"R18-20260422","doi-asserted-by":"crossref","first-page":"e027572.","DOI":"10.1136\/bmjopen-2018-027572","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA): A scoping review protocol concerning indications-advantages and challenges of implementation in traumatic non-compressible torso haemorrhage","volume":"9","author":"Bekdache","year":"2019","journal-title":"BMJ Open"},{"key":"R19-20260422","doi-asserted-by":"crossref","first-page":"e000262.","DOI":"10.1136\/tsaco-2018-000262","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA): Indications: Advantages and challenges of implementation in traumatic non-compressible torso hemorrhage","volume":"4","author":"Bekdache","year":"2019","journal-title":"Trauma Surg Acute Care Open"},{"key":"R20-20260422","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1097\/TA.0000000000000614","article-title":"Evaluation of the safety and feasibility of resuscitative endovascular balloon occlusion of the aorta","volume":"78","author":"Saito","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"key":"R21-20260422","first-page":"65","article-title":"Use of an intra-aortic balloon catheter tamponade for controlling intra-abdominal hemorrhage in man","volume":"36","author":"Hughes","year":"1954","journal-title":"Surgery"},{"key":"R22-20260422","first-page":"1024","article-title":"An aortic tampon for emergency control of ruptured abdominal aneurysm","volume":"91","author":"Heimbecker","year":"1964","journal-title":"Can Med Assoc J"},{"key":"R23-20260422","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/S0196-0644(86)80945-3","article-title":"Preliminary report on the use of the percluder occluding aortic balloon in human beings","volume":"15","author":"Low","year":"1986","journal-title":"Ann Emerg Med"},{"key":"R24-20260422","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1097\/00005373-198906000-00026","article-title":"The role of intra-aortic balloon occlusion in penetrating abdominal trauma","volume":"29","author":"Gupta","year":"1989","journal-title":"J Trauma"},{"key":"R25-20260422","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.surg.2011.06.010","article-title":"Endovascular balloon occlusion of the aorta is superior to resuscitative thoracotomy with aortic clamping in a porcine model of hemorrhagic shock","volume":"150","author":"White","year":"2011","journal-title":"Surgery"},{"key":"R26-20260422","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1097\/TA.0000000000000609","article-title":"The role of REBOA in the control of exsanguinating torso hemorrhage","volume":"78","author":"Biffl","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"key":"R27-20260422","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1097\/TA.0000000000000164","article-title":"Endovascular skills for trauma and resuscitative surgery (ESTARS) course: Curriculum development, content validation, and program assessment","volume":"76","author":"Villamaria","year":"2014","journal-title":"J Trauma Acute Care Surg"},{"key":"R28-20260422","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/TA.0000000000001711","article-title":"The pitfalls of resuscitative endovascular balloon occlusion of the aorta: Risk factors and mitigation strategies","volume":"84","author":"Davidson","year":"2018","journal-title":"J Trauma Acute Care Surg"},{"key":"R29-20260422","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.jemermed.2018.01.005","article-title":"Successful interprofessional approach to development of a resuscitative endovascular balloon occlusion of the aorta program at a community trauma center","volume":"54","author":"Qasim","year":"2018","journal-title":"J Emerg Med"},{"key":"R30-20260422","doi-asserted-by":"crossref","first-page":"e000335.","DOI":"10.1136\/tsaco-2019-000335","article-title":"\u2018Step Up\u2019 approach to the application of REBOA technology in a rural trauma system","volume":"4","author":"Vernamonti","year":"2019","journal-title":"Trauma Surg Acute Care Open"},{"key":"R31-20260422","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/j.jvs.2014.05.028","article-title":"Trends and outcomes of endovascular therapy in the management of civilian vascular injuries","volume":"60","author":"Branco","year":"2014","journal-title":"J Vasc Surg"},{"key":"R32-20260422","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1177\/153857440604000210","article-title":"Clamp before you cut: Proximal control of ruptured abdominal aortic aneurysms using endovascular balloon occlusion \u2013 Case reports","volume":"40","author":"Arthurs","year":"2006","journal-title":"Vasc Endovascular Surg"},{"key":"R33-20260422","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1097\/SLA.0b013e31819a8b65","article-title":"10 years of emergency endovascular aneurysm repair for ruptured abdominal aortoiliac aneurysms: Lessons learned","volume":"249","author":"Mayer","year":"2009","journal-title":"Ann Surg"},{"key":"R34-20260422","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1111\/j.1399-6576.2011.02611.x","article-title":"The use of aortic occlusion balloon catheter without fluoroscopy for life-threatening post-partum haemorrhage","volume":"56","author":"S\u00f8vik","year":"2012","journal-title":"Acta Anaesthesiol Scand"},{"key":"R35-20260422","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1067\/mem.2001.114408","article-title":"Use of the intra-aortic balloon pump to stop gastrointestinal bleeding","volume":"38","author":"Karkos","year":"2001","journal-title":"Ann Emerg Med"},{"key":"R36-20260422","doi-asserted-by":"crossref","first-page":"1.","DOI":"10.1186\/1749-7922-10-1","article-title":"Retrospective study of the effectiveness of Intra-aortic balloon occlusion (IABO) for traumatic haemorrhagic shock","volume":"10","author":"Irahara","year":"2015","journal-title":"World J Emerg Surg"},{"key":"R37-20260422","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1097\/TA.0000000000000578","article-title":"Survival of severe blunt trauma patients treated with resuscitative endovascular balloon occlusion of the aorta compared with propensity score-adjusted untreated patients","volume":"78","author":"Norii","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"key":"R38-20260422","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1007\/s00068-018-0973-0","article-title":"Resuscitative endovascular balloon occlusion of the aorta for non-traumatic intra-abdominal hemorrhage","volume":"45","author":"Hoehn","year":"2019","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R39-20260422","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.gassur.2005.09.019","article-title":"Aortic occlusion balloon catheter technique is useful for uncontrollable massive intraabdominal bleeding after hepato-pancreato-biliary surgery","volume":"10","author":"Miura","year":"2006","journal-title":"J Gastrointest Surg"},{"key":"R40-20260422","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1097\/TA.0000000000003193","article-title":"Is resuscitative endovascular balloon occlusion of the aorta for computed tomography diagnosis feasible or not? A Japanese single-center, retrospective, observational study","volume":"91","author":"Otsuka","year":"2021","journal-title":"J Trauma Acute Care Surg"},{"key":"R41-20260422","doi-asserted-by":"crossref","first-page":"e0243658.","DOI":"10.1371\/journal.pone.0243658","article-title":"Maturation process and international accreditation of trauma system in a rapidly developing country","volume":"15","author":"El-Menyar","year":"2020","journal-title":"PLoS One"},{"key":"R42-20260422","doi-asserted-by":"crossref","first-page":"209","DOI":"10.4103\/JETS.JETS_56_19","article-title":"Evolution of the Qatar trauma system: The journey from inception to verification","volume":"12","author":"Al-Thani","year":"2019","journal-title":"J Emerg Trauma Shock"},{"key":"R43-20260422","doi-asserted-by":"crossref","first-page":"S133","DOI":"10.1097\/TA.0000000000001146","article-title":"Partial resuscitative balloon occlusion of the aorta (P-REBOA): Clinical technique and rationale","volume":"81","author":"Johnson","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"key":"R44-20260422","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/ACO.0000000000000699","article-title":"Resuscitative endovascular balloon occlusion of the aorta: An option for noncompressible torso hemorrhage?","volume":"32","author":"Kulla","year":"2019","journal-title":"Curr Opin Anaesthesiol"},{"key":"R45-20260422","doi-asserted-by":"crossref","first-page":"e146","DOI":"10.1213\/ANE.0000000000004130","article-title":"Anesthetic management of patients after traumatic injury with resuscitative endovascular balloon occlusion of the aorta","volume":"129","author":"Engdahl","year":"2019","journal-title":"Anesth Analg"},{"key":"R46-20260422","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1097\/TA.0000000000004109","article-title":"Vascular access complications associated with resuscitative endovascular balloon occlusion of the aorta in adult trauma patients: A systematic review and meta-analysis","volume":"96","author":"Shum-Tim","year":"2024","journal-title":"J Trauma Acute Care Surg"},{"key":"R47-20260422","doi-asserted-by":"crossref","first-page":"e001267.","DOI":"10.1136\/tsaco-2023-001267","article-title":"Complications associated with the use of Resuscitative endovascular balloon occlusion of the aorta (REBOA): An updated review","volume":"9","author":"Fontenelle Ribeiro","year":"2024","journal-title":"Trauma Surg Acute Care Open"},{"key":"R48-20260422","doi-asserted-by":"crossref","first-page":"20.","DOI":"10.1186\/s13017-018-0181-6","article-title":"The complications associated with Resuscitative endovascular balloon occlusion of the aorta (REBOA)","volume":"13","author":"Ribeiro","year":"2018","journal-title":"World J Emerg Surg"},{"key":"R49-20260422","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1007\/s00104-020-01180-0","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA): Current aspects of material, indications and limits: An overview","volume":"91","author":"Wortmann","year":"2020","journal-title":"Chirurg"},{"key":"R50-20260422","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1177\/1460408617738810","article-title":"A one-year cost-utility analysis of REBOA versus RTACC for non-compressible torso haemorrhage","volume":"21","author":"Renna","year":"2019","journal-title":"Trauma"},{"key":"R51-20260422","doi-asserted-by":"crossref","first-page":"e000376.","DOI":"10.1136\/tsaco-2019-000376","article-title":"Clinical use of Resuscitative endovascular balloon occlusion of the aorta (REBOA) in civilian trauma systems in the USA, 2019: A joint statement from the American College of Surgeons Committee on Trauma, the American College of Emergency Physicians, the National Association of Emergency Medical Services Physicians and the National Association of Emergency Medical Technicians","volume":"4","author":"Bulger","year":"2019","journal-title":"Trauma Surg Acute Care Open"},{"key":"R52-20260422","doi-asserted-by":"crossref","first-page":"8.","DOI":"10.1186\/s13049-020-00807-9","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA): Update and insights into current practices and future directions for research and implementation","volume":"29","author":"Thrailkill","year":"2021","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"R53-20260422","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.1016\/j.jpedsurg.2020.01.052","article-title":"The utility and promise of Resuscitative endovascular balloon occlusion of the aorta (REBOA) in the pediatric population: An evidence-based review","volume":"55","author":"Campagna","year":"2020","journal-title":"J Pediatr Surg"}],"container-title":["Journal of Emergencies, Trauma, and Shock"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jets.jets_79_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:53:28Z","timestamp":1786647208000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jets.jets_79_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":53,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jets.jets_79_24","relation":{},"ISSN":["0974-2700","0974-519X"],"issn-type":[{"value":"0974-2700","type":"print"},{"value":"0974-519X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2024-06-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}