{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T20:39:07Z","timestamp":1786653547012,"version":"build-2736575974"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>BSTRACT<\/jats:sc>\n                  <\/jats:title>\n                  <jats:p>Implantable contraceptives provide a temporary, long-acting, and reversible form of contraception. Implant migration is a rare complication, with potential damage to the musculature or neurovascular structures. This is a case of a Nexplanon implant migration into the biceps brachii muscle, requiring surgical removal. Implants that become non-palpable should be immediately visualized with imaging to prevent further nerve or vascular injury and subsequently be removed.<\/jats:p>","DOI":"10.4103\/jfmpc.jfmpc_1371_24","type":"journal-article","created":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T04:04:36Z","timestamp":1742789076000},"page":"1131-1134","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Complication of Nexplanon contraceptive implant requiring intramuscular removal from biceps: A Case Report"],"prefix":"10.4103","volume":"14","author":[{"given":"Harvey","family":"Wang","sequence":"first","affiliation":[{"name":"Creighton University School of Medicine \u2013 Phoenix Regional Campus, Phoenix, AZ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yogesh","family":"Kolwadkar","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Laredo Sports Medicine Clinic, Laredo, TX, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,3,25]]},"reference":[{"key":"R1-20250325","doi-asserted-by":"crossref","first-page":"104639","DOI":"10.1016\/j.nurpra.2023.104639","article-title":"Adolescent contraception management:A review of medical options","volume":"19","author":"Stanley","year":"2023","journal-title":"J Nurse Pract"},{"key":"R2-20250325","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s12978-020-01054-y","article-title":"A systematic review on clinical effectiveness, side-effect profile and meta-analysis on continuation rate of etonogestrel contraceptive implant","volume":"18","author":"Moray","year":"2021","journal-title":"Reprod Health"},{"key":"R3-20250325","doi-asserted-by":"crossref","first-page":"710","DOI":"10.3109\/09513590.2011.652247","article-title":"Nexplanon:The new implant for long-term contraception. A comprehensive descriptive review","volume":"28","author":"Palomba","year":"2012","journal-title":"Gynecol Endocrinol"},{"key":"R4-20250325","doi-asserted-by":"crossref","first-page":"bcr2017219259","DOI":"10.1136\/bcr-2017-219259","article-title":"Migration of a Nexplanon contraceptive implant to the pulmonary artery","volume":"2017","author":"Barlow-Evans","year":"2017","journal-title":"BMJ Case Rep"},{"key":"R5-20250325","doi-asserted-by":"crossref","first-page":"3973","DOI":"10.1016\/j.radcr.2021.09.051","article-title":"Nexplanon removal from intramuscular implantation in biceps:Case report","volume":"16","author":"Kong","year":"2021","journal-title":"Radiol Case Rep"},{"key":"R6-20250325","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1111\/ajo.13257","article-title":"Changes in use of hormonal long-acting reversible contraceptive methods in Australia between 2006 and 2018:A population-based study","volume":"61","author":"Grzeskowiak","year":"2021","journal-title":"Aust N Z J Obstet Gynaecol"},{"key":"R7-20250325","doi-asserted-by":"crossref","first-page":"352.e1","DOI":"10.1016\/j.ajog.2015.04.025","article-title":"A population-based study of US women's preferred versus usual sources of reproductive health care","volume":"213","author":"Hall","year":"2015","journal-title":"Am J Obstet Gynecol"},{"key":"R8-20250325","doi-asserted-by":"crossref","first-page":"9","DOI":"10.4300\/JGME-D-14-00010.1","article-title":"Knowledge and training of intrauterine devices among primary care residents:Implications for graduate medical education","volume":"7","author":"Sridhar","year":"2015","journal-title":"J Grad Med Educ"},{"key":"R9-20250325","doi-asserted-by":"crossref","first-page":"660","DOI":"10.22454\/FamMed.2023.694219","article-title":"Barriers to and facilitators of contraceptive implant training in new jersey family medicine residencies:A qualitative study","volume":"55","author":"Mischell","year":"2023","journal-title":"Fam Med"},{"key":"R10-20250325","first-page":"e2132","article-title":"Complications of subcutaneous contraception:A review","volume":"10","author":"Ramdhan","year":"2018","journal-title":"Cureus"},{"key":"R11-20250325","first-page":"548","article-title":"Safety and benefits of contraceptives implants:A systematic review","volume":"14","author":"Rocca","year":"2021","journal-title":"Pharm Basel Switz"},{"key":"R12-20250325","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.contraception.2005.10.009","article-title":"Management and localization strategies for the nonpalpable Implanon rod","volume":"73","author":"Shulman","year":"2006","journal-title":"Contraception"},{"key":"R13-20250325","doi-asserted-by":"crossref","first-page":"388.e1","DOI":"10.1016\/j.ajog.2012.08.002","article-title":"Nexplanon, a radiopaque etonogestrel implant in combination with a next-generation applicator:3-Year results of a noncomparative multicenter trial","volume":"207","author":"Mommers","year":"2012","journal-title":"Am J Obstet Gynecol"},{"key":"R14-20250325","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1186\/s12913-024-10991-4","article-title":"Offering extended use of the contraceptive implant via an implementation science framework:A qualitative study of clinicians'perceived barriers and facilitators","volume":"24","author":"Rigler","year":"2024","journal-title":"BMC Health Serv Res"},{"key":"R15-20250325","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s40834-018-0070-0","article-title":"Peripheral nerve injury with Nexplanon removal:Case report and review of the literature","volume":"3","author":"Lefebvre","year":"2018","journal-title":"Contracept Reprod Med"},{"key":"R16-20250325","first-page":"e48179","article-title":"Migration of a contraceptive subdermal device into the lung","volume":"15","author":"Enabi","journal-title":"Cureus"},{"key":"R17-20250325","doi-asserted-by":"crossref","first-page":"e18881","DOI":"10.1097\/MD.0000000000018881","article-title":"Nexplanon migration into a subsegmental branch of the pulmonary artery","volume":"99","author":"Hindy","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"R18-20250325","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1016\/j.radcr.2018.08.034","article-title":"Endovascular retrieval of contraceptive implant embolized to pulmonary artery","volume":"13","author":"Wilcox","year":"2018","journal-title":"Radiol Case Rep"},{"key":"R19-20250325","doi-asserted-by":"crossref","first-page":"111","DOI":"10.2147\/OAJC.S368250","article-title":"Characteristics of patients requiring surgical removal of subdermal contraceptive implants:A case-control study","volume":"13","author":"Katabi","year":"2022","journal-title":"Open Access J Contracept"}],"container-title":["Journal of Family Medicine and Primary Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jfmpc.jfmpc_1371_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:39:07Z","timestamp":1786649947000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jfmpc.jfmpc_1371_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jfmpc.jfmpc_1371_24","relation":{},"ISSN":["2249-4863","2278-7135"],"issn-type":[{"value":"2249-4863","type":"print"},{"value":"2278-7135","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3]]},"assertion":[{"value":"2024-08-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-10-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}