{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:30:40Z","timestamp":1787841040474,"version":"build-2784847793"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>BSTRACT<\/jats:sc>\n                  <\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Hypertension is a leading cause of co-morbidities across the world. Among hypertensive patients, a simple self-monitoring of blood pressure (BP) can improve compliance toward lifestyle modifications and drugs. A wide variety of electronic devices for the measurement of BP are available in the market and are recommended by different authorities. Owing to the portability and ease of its use, wrist BP monitors are an attractive alternative to the routine aneroid sphygmomanometers. However, there are no Indian studies on the comparison of wrist BP monitors based on oscillometry with the standard upper arm BP measurement using an aneroid BP instrument.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Simultaneous BP readings were recorded under ideal conditions, in accordance to AHA guidelines, using a wrist BP monitor and aneroid sphygmomanometer in 150 healthy volunteers. The average of the systolic BP (SBP) and diastolic BP (DBP), mean arterial pressure, and pulse pressures (PPs) measured by the two instruments were calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results and Conclusion:<\/jats:title>\n                    <jats:p>It was found that the wrist BP monitor overestimates systolic, diastolic, mean arterial, and PP readings when compared to the aneroid meter. Our findings are concordant with some previous studies that elaborate on the exaggeration of both SBP and DBP by wrist monitor by a marginal value.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jfmpc.jfmpc_323_25","type":"journal-article","created":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T21:00:30Z","timestamp":1759006830000},"page":"3698-3702","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A comparison of utility of a wrist-worn blood pressure monitor with arm cuff aneroid sphygmomanometer"],"prefix":"10.4103","volume":"14","author":[{"given":"Divyanshu Mohan","family":"Arya","sequence":"first","affiliation":[{"name":"Undergraduate MBBS Students, All Institute of Medical Sciences, Raebareli, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meet Dineshbhai","family":"Gajjar","sequence":"additional","affiliation":[{"name":"Undergraduate MBBS Students, All Institute of Medical Sciences, Raebareli, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rishu","family":"Anand","sequence":"additional","affiliation":[{"name":"Undergraduate MBBS Students, All Institute of Medical Sciences, Raebareli, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harshit","family":"Kumar","sequence":"additional","affiliation":[{"name":"Undergraduate MBBS Students, All Institute of Medical Sciences, Raebareli, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shruti","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Pathology and Lab Medicine, All Institute of Medical Sciences, Raebareli, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niraj","family":"Kumari","sequence":"additional","affiliation":[{"name":"Department of Pathology and Lab Medicine, All Institute of Medical Sciences, Raebareli, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,9,29]]},"reference":[{"key":"R1-20251009","doi-asserted-by":"crossref","first-page":"e2339098","DOI":"10.1001\/jamanetworkopen.2023.39098","article-title":"Hypertension diagnosis, treatment, and control in India","volume":"6","author":"Varghese","year":"2023","journal-title":"JAMA Netw Open"},{"key":"R2-20251009","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1111\/jch.13647","article-title":"Self-blood pressure monitoring is associated with improved awareness, adherence, and attainment of target blood pressure goals: Prospective observational study of 7751 patients","volume":"21","author":"Jo","year":"2019","journal-title":"J Clin Hypertens (Greenwich)"},{"key":"R3-20251009","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1038\/jhh.2010.37","article-title":"Determining which automatic digital blood pressure device performs adequately: A systematic review","volume":"24","author":"Wan","year":"2010","journal-title":"J Hum Hypertens"},{"key":"R4-20251009","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1097\/HJH.0000000000002843","article-title":"2021 European Society of Hypertension practice guidelines for office and out-of-office blood pressure measurement","volume":"39","author":"Stergiou","year":"2021","journal-title":"J Hypertens"},{"key":"R6-20251009","first-page":"7693","article-title":"Correlation between electronic wrist blood pressure with auscultatory blood pressure in children","volume":"27","author":"\u00d6ztorun","year":"2023","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"R7-20251009","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2147\/VHRM.S188089","article-title":"Validation of two automatic devices, Omron HEM-6232T and HEM-6181, for self-measurement of blood pressure at the wrist according to the ANSI\/AAMI\/ISO 81060-2: 2013 protocol and the European Society of Hypertension International Protocol revision 2010","volume":"15","author":"Saito","year":"2019","journal-title":"Vasc Health Risk Manag"},{"issue":"7-8_suppl","key":"R8-20251009","doi-asserted-by":"crossref","first-page":"40S","DOI":"10.1177\/08982643211013692","article-title":"Home blood pressure monitoring devices: Device performance in an Alaska Native and American Indian Population","volume":"33","author":"Schaefer","year":"2021","journal-title":"J Aging Health"},{"key":"R9-20251009","first-page":"171","article-title":"Validation of an automatic wrist blood pressure monitor in a critical care setting","volume":"272","author":"Karampela","year":"2020","journal-title":"Stud Health Technol Inform"},{"key":"R10-20251009","doi-asserted-by":"crossref","first-page":"61","DOI":"10.2147\/VHRM.S126285","article-title":"Questionable accuracy of home blood pressure measurements in the obese population-validation of the Microlife WatchBP O3\u00ae and Omron RS6\u00ae devices according to the European Society of Hypertension-International Protocol","volume":"13","author":"Azaki","year":"2017","journal-title":"Vasc Health Risk Manag"},{"key":"R11-20251009","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1161\/STROKEAHA.107.510677","article-title":"Pulse pressure and mean arterial pressure in relation to ischemic stroke among patients with uncontrolled hypertension in rural areas of China","volume":"39","author":"Zheng","year":"2008","journal-title":"Stroke"},{"key":"R12-20251009","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1001\/archinte.160.8.1085","article-title":"Pulse pressure not mean pressure determines cardiovascular risk in older hypertensive patients","volume":"160","author":"Blacher","year":"2000","journal-title":"Arch Intern Med"}],"container-title":["Journal of Family Medicine and Primary Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jfmpc.jfmpc_323_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:40:07Z","timestamp":1787838007000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jfmpc.jfmpc_323_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":11,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jfmpc.jfmpc_323_25","relation":{},"ISSN":["2249-4863","2278-7135"],"issn-type":[{"value":"2249-4863","type":"print"},{"value":"2278-7135","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"2025-02-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}