{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T13:01:42Z","timestamp":1792155702302,"version":"4.4.0"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>To evaluate and compare the effect of repeated sterilization cycles on linear, angular, and diameter changes, and overall implant position transfer accuracy of titanium and polyetheretherketone (PEEK) scan bodies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>\n                      An\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      study.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      An\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      study was conducted using two maxillary acrylic models with implant analogues. Titanium and PEEK scan bodies were scanned using an intraoral scanner, with the initial scan serving as the reference. Each scan body underwent 14 steam autoclave cycles (134\u00b0C for 10 min followed by 15 min drying). Scans were exported as STL files and superimposed onto the reference dataset. Linear, angular, diameter, and root mean square (RMS) deviations were measured.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>\n                      Data were analyzed using repeated measures analysis of variance (ANOVA). Mean differences with 95% confidence intervals were calculated, and statistical significance was set at\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Both materials showed deviations after repeated sterilization; however, titanium scan bodies exhibited significantly lower linear, angular, and RMS deviations. PEEK demonstrated greater variability and dimensional changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Repeated sterilization affects scan body accuracy in a material-dependent manner. Titanium scan bodies showed superior dimensional stability and more consistent implant position transfer than PEEK.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jips.jips_149_26","type":"journal-article","created":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T05:13:48Z","timestamp":1782882828000},"page":"283-288","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Impact of repeated usage of two different scan bodies on the accuracy of implant position transfer: An in vitro study"],"prefix":"10.4103","volume":"26","author":[{"given":"Koustubh Sharadkumar","family":"Shinde","sequence":"first","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Sri Siddhartha Academy of Higher Education, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Raghavendra Prasad","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Sri Siddhartha Academy of Higher Education, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K","family":"Chethana","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Sri Siddhartha Academy of Higher Education, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,1]]},"reference":[{"key":"R1-20260701","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1007\/s00784-011-0564-5","article-title":"Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study","volume":"16","author":"Stimmelmayr","year":"2012","journal-title":"Clin Oral Investig"},{"key":"R2-20260701","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3390\/bioengineering5010018","article-title":"Effects of sterilization cycles on PEEK for medical device application","volume":"5","author":"Kumar","year":"2018","journal-title":"Bioengineering (Basel)"},{"key":"R3-20260701","doi-asserted-by":"crossref","first-page":"891","DOI":"10.11607\/jomi.6945","article-title":"Effect of multiple use of impression copings and scanbodies on implant cast accuracy","volume":"34","author":"Sawyers","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"key":"R4-20260701","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jpor.2019.06.001","article-title":"Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial","volume":"64","author":"Arcuri","year":"2020","journal-title":"J Prosthodont Res"},{"key":"R5-20260701","doi-asserted-by":"crossref","first-page":"927","DOI":"10.3390\/ma15030927","article-title":"Influence of implant scanbody wear on the accuracy of digital impression for complete-arch: A randomized in vitro trial","volume":"15","author":"Arcuri","year":"2022","journal-title":"Materials (Basel)"},{"key":"R6-20260701","first-page":"410","article-title":"Effect of repeated use of different types of scan bodies on transfer accuracy of implant position","volume":"24","author":"Mahmoud Hashemi","year":"2023","journal-title":"J Dent (Shiraz)"},{"key":"R7-20260701","first-page":"419","article-title":"Sterilization analysis of contaminated healing abutments and impression copings","volume":"40","author":"Browne","year":"2012","journal-title":"J Calif Dent Assoc"},{"key":"R8-20260701","doi-asserted-by":"crossref","first-page":"408","DOI":"10.11607\/jomi.2717","article-title":"Effect of multiple use of impression copings on the accuracy of implant transfer","volume":"28","author":"Alikhasi","year":"2013","journal-title":"Int J Oral Maxillofac Implants"},{"key":"R9-20260701","doi-asserted-by":"crossref","first-page":"7717","DOI":"10.3390\/ma15217717","article-title":"Effects of autoclave sterilization and multiple use on implant scanbody deformation in vitro","volume":"15","author":"Kato","year":"2022","journal-title":"Materials (Basel)"},{"key":"R10-20260701","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1111\/cid.13187","article-title":"Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study","volume":"25","author":"Diker","year":"2023","journal-title":"Clin Implant Dent Relat Res"}],"container-title":["The Journal of Indian Prosthodontic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.4103\/jips.jips_149_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:49:44Z","timestamp":1782928184000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.4103\/jips.jips_149_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jips.jips_149_26","relation":{},"ISSN":["0972-4052","1998-4057"],"issn-type":[{"value":"0972-4052","type":"print"},{"value":"1998-4057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2026-04-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}