{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:00:32Z","timestamp":1793196032440,"version":"4.5.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>The widespread use of printable resins contrasts with the limited evaluation of residual monomer release, that remains a significant concern for biocompatibility. Fewer studies estimated the monomer releases in printable denture base resins. The study evaluated the effect of glycerol-assisted UV post-curing at different time intervals on residual monomer release from 3D printed denture base resin.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Setting and Design:<\/jats:title>\n                    <jats:p>\n                      <jats:italic toggle=\"yes\">Invitro<\/jats:italic>\n                      experimental study.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methodology:<\/jats:title>\n                    <jats:p>Forty standardized specimens of 50 mm diameter \u00d7 3 \u00b1 0.1 mm thickness were made using a DLP 3D printer in accordance with ISO 20795-1:2013 specifications. Following printing and ethanol washing, specimens were immersed in glycerol and subjected to UV post-curing at 0, 10, 20, and 30 minutes. Residual methyl methacrylate (MMA) release was measured by means of high-performance liquid chromatography (HPLC), and values were compared across groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis:<\/jats:title>\n                    <jats:p>Kruskal\u2013Wallis test and Dunn\u2019s post hoc test with Bonferroni corrections.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Reduction in MMA release was observed with increasing post-curing duration (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Mean values decreased progressively from 26.68 ppm (0 min) to 7.78 ppm (30 min), with the 30-minute group demonstrating the lowest monomer elution.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Glycerol-assisted UV post-curing significantly reduced residual monomer release. A 30-minute curing duration appears optimal for improving polymerization and enhancing biocompatibility.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jips.jips_19_26","type":"journal-article","created":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T05:09:41Z","timestamp":1782882581000},"page":"245-251","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Effect of glycerol-assisted ultraviolet postcuring duration on residual monomer release from 3D-printed denture base resins"],"prefix":"10.4103","volume":"26","author":[{"given":"Naveen Gopi","family":"Chander","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harini Gnana","family":"Prakash","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aryan Shivaji","family":"Deshmukh","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thummala Venkata Sai","family":"Swetha","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,1]]},"reference":[{"key":"R1-20260701","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s10856-023-06729-z","article-title":"Degree of conversion and residual monomer elution of 3D-printed, milled and self-cured resin-based composite materials for temporary dental crowns and bridges","volume":"34","author":"Berghaus","year":"2023","journal-title":"J Mater Sci Mater Med"},{"key":"R2-20260701","doi-asserted-by":"crossref","first-page":"104094","DOI":"10.1016\/j.jdent.2022.104094","article-title":"Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: An in vitro study","volume":"120","author":"Srinivasan","year":"2022","journal-title":"J Dent"},{"key":"R3-20260701","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.12688\/f1000research.157596.2","article-title":"The science of printing and polishing 3D printed dentures","volume":"13","author":"Sulaya","year":"2025","journal-title":"F1000Res"},{"key":"R4-20260701","doi-asserted-by":"crossref","first-page":"152","DOI":"10.3390\/ijms25010152","article-title":"Considerations about cytotoxicity of resin-based composite dental materials: A systematic review","volume":"25","author":"Wiertelak-Makaa","year":"2024","journal-title":"Int J Mol Sci"},{"key":"R5-20260701","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.3390\/polym14091790","article-title":"Monomer release from dental resins: The current status on study setup, detection and quantification for in vitro testing","volume":"14","author":"Hampe","year":"2022","journal-title":"Polymers (Basel)"},{"key":"R6-20260701","doi-asserted-by":"crossref","first-page":"265.e1","DOI":"10.1016\/j.prosdent.2023.05.008","article-title":"Influence of postpolymerization time and atmosphere on the mechanical properties, degree of conversion, and cytotoxicity of denture bases produced by digital light processing","volume":"130","author":"Lee","year":"2023","journal-title":"J Prosthet Dent"},{"key":"R7-20260701","doi-asserted-by":"crossref","first-page":"105170","DOI":"10.1016\/j.jmbbm.2022.105170","article-title":"Evaluating oxygen shielding effect using glycerin or vacuum with varying temperature on 3D printed photopolymer in post-polymerization","volume":"130","author":"Lim","year":"2022","journal-title":"J Mech Behav Biomed Mater"},{"key":"R8-20260701","doi-asserted-by":"crossref","first-page":"2887","DOI":"10.1007\/s00784-021-04271-2","article-title":"Comparative analysis of leaching residual monomer and biological effects of four types of conventional and CAD\/CAM dental polymers: An in vitro study","volume":"26","author":"Wei","year":"2022","journal-title":"Clin Oral Investig"},{"key":"R9-20260701","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1016\/j.dental.2020.09.002","article-title":"Monomer release from surgical guide resins manufactured with different 3D printing devices","volume":"36","author":"Kessler","year":"2020","journal-title":"Dent Mater"},{"key":"R10-20260701","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1111\/jopr.13538","article-title":"Comparison of dimensional changes between CAD-CAM milled complete denture bases and 3D printed complete denture bases: An in vitro study","volume":"32","author":"Helal","year":"2023","journal-title":"J Prosthodont"},{"key":"R11-20260701","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.jdent.2003.12.004","article-title":"Leachability of plasticizer and residual monomer from commercial temporary restorative resins","volume":"32","author":"Kawahara","year":"2004","journal-title":"J Dent"},{"key":"R12-20260701","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.3390\/ma17051052","article-title":"The influence of contemporary denture base fabrication methods on residual monomer content, flexural strength and microhardness","volume":"17","author":"Vuksic","year":"2024","journal-title":"Materials (Basel)"},{"key":"R13-20260701","doi-asserted-by":"crossref","first-page":"e236361","DOI":"10.1590\/0103-644020256361","article-title":"Effect of glycerin gel application for post-curing process on the flexural strength, elastic modulus, and microhardness of 3D printing resins","volume":"36","author":"Soares","year":"2025","journal-title":"Braz Dent J"},{"key":"R14-20260701","doi-asserted-by":"crossref","first-page":"160","DOI":"10.4047\/jap.2021.13.3.160","article-title":"Color stability of 3D-printed denture resins: Effect of aging, mechanical brushing and immersion in staining medium","volume":"13","author":"Alfouzan","year":"2021","journal-title":"J Adv Prosthodont"},{"key":"R15-20260701","doi-asserted-by":"crossref","first-page":"105431","DOI":"10.1016\/j.jdent.2024.105431","article-title":"Evaluation of the dimensional stability of 3D-printed dental casts","volume":"151","author":"Vincze","year":"2024","journal-title":"J Dent"},{"key":"R16-20260701","doi-asserted-by":"crossref","first-page":"553","DOI":"10.2186\/jpr.JPR_D_24_00221","article-title":"Effects of post-polymerization conditions on the mechanical properties of 3D-printed dental resin nanocomposite","volume":"69","author":"Qi","year":"2025","journal-title":"J Prosthodont Res"},{"key":"R17-20260701","first-page":"12","article-title":"Post-curing protocols and dimensional accuracy of 3D-printed resin materials","volume":"7","author":"Aksoy","year":"2025","journal-title":"Clin Investig Orthod"},{"key":"R18-20260701","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.1016\/j.prosdent.2024.08.014","article-title":"Effectiveness of postprocessing on 3D printed resin biocompatibility in prosthodontics: A systematic review","volume":"134","author":"Cabrol","year":"2025","journal-title":"J Prosthet Dent"}],"container-title":["The Journal of Indian Prosthodontic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.4103\/jips.jips_19_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:50:37Z","timestamp":1782928237000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.4103\/jips.jips_19_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jips.jips_19_26","relation":{},"ISSN":["0972-4052","1998-4057"],"issn-type":[{"value":"0972-4052","type":"print"},{"value":"1998-4057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2026-01-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}