{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T14:01:05Z","timestamp":1790863265328,"version":"4.1.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>This study aimed to compare the marginal and internal adaptation of monolithic computer-aided design and computer-aided manufacturing (CAD\/CAM) zirconia crowns and heat-pressed ceramic-veneered zirconia crowns fabricated using a standardized digital workflow.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>\n                      An\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      laboratory study was conducted using standardized epoxy resin dies and zirconia crowns fabricated by two different laboratory workflows.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Twenty zirconia crowns were fabricated from a single STL dataset with a 50-\u00b5m cement space and divided into two groups (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 10): monolithic CAD\/CAM zirconia (MZ) and bilayer heat-pressed ceramic-on-zirconia (PVZ). All crowns were fabricated on epoxy resin dies replicated from a CAD\/CAM-milled stainless-steel master die. After cementation with glass ionomer cement under a controlled seating load of 50 N, the specimens were sectioned buccolingually. Marginal and internal gaps were measured using scanning electron microscopy at eight predetermined sites.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>\n                      Data were evaluated for normality using the Shapiro\u2013Wilk test. Intergroup comparisons were performed using the Mann\u2013Whitney U-test, with statistical significance set at\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05. Bonferroni adjustment was applied for exploratory multiple comparisons.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      For the primary outcome, composite internal adaptation was lower in the monolithic CAD\/CAM zirconia crown group than in the heat-pressed ceramic-veneered zirconia crown group (103.07 vs. 111.38 \u00b5m;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.019), with a moderate effect size (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.53). Composite marginal adaptation did not differ significantly between the groups (88.90 vs. 95.73 \u00b5m;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.226).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Both fabrication workflows produced zirconia crowns with marginal and internal adaptations within clinically acceptable limits. Monolithic CAD\/CAM zirconia crowns showed slightly smaller internal discrepancies than heat-pressed ceramic-veneered zirconia crowns; however, the magnitude of this difference is unlikely to affect clinical seating or cementation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jips.jips_289_26","type":"journal-article","created":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T10:01:03Z","timestamp":1790848863000},"page":"397-404","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Marginal and internal adaptation of monolithic computer-aided design and computer-aided manufacturing zirconia crowns and heat-pressed ceramic veneered zirconia crowns: An in vitro study"],"prefix":"10.4103","volume":"26","author":[{"given":"Smruti","family":"Nanda","sequence":"first","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha \u2018O\u2019 Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirna","family":"Garhnayak","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha \u2018O\u2019 Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhijita","family":"Mohapatra","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha \u2018O\u2019 Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sangram","family":"Panda","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha \u2018O\u2019 Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhilash","family":"Mohapatra","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha \u2018O\u2019 Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gopal Krishna","family":"Choudhury","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha \u2018O\u2019 Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,10,1]]},"reference":[{"key":"R1-20261001","doi-asserted-by":"crossref","first-page":"4956","DOI":"10.1016\/j.jmrt.2019.06.043","article-title":"Zirconia in dental prosthetics: A literature review","volume":"8","author":"Grech","year":"2019","journal-title":"J Mater Res Technol"},{"key":"R2-20261001","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1038\/s41415-024-7616-0","article-title":"Emerging trends and clinical recommendations for zirconia ceramic crowns: A concise review","volume":"237","author":"Vijan","year":"2024","journal-title":"Br Dent J"},{"key":"R3-20261001","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1038\/s41405-024-00214-7","article-title":"Fifteen-year recall period on zirconia-based single crowns and fixed dental prostheses. A prospective observational study","volume":"10","author":"Khijmatgar","year":"2024","journal-title":"BDJ Open"},{"key":"R4-20261001","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1186\/s12903-025-05947-x","article-title":"Marginal and internal adaptation and absolute marginal discrepancy of 3D-printed, milled, and prefabricated crowns for primary molar teeth: An in vitro comparative study","volume":"25","author":"Akta\u015f","year":"2025","journal-title":"BMC Oral Health"},{"key":"R5-20261001","first-page":"2029","article-title":"Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by four different CAD\/CAM systems","volume":"25","author":"Duarte","year":"2020","journal-title":"Clin Oral Investig"},{"key":"R6-20261001","doi-asserted-by":"crossref","first-page":"54","DOI":"10.4103\/njcp.njcp_410_23","article-title":"Evaluation of marginal and internal adaptation of crowns fabricated with three different zirconia CAD\/CAM materials","volume":"27","author":"Temizkan Nizaroglu","year":"2024","journal-title":"Niger J Clin Pract"},{"key":"R7-20261001","doi-asserted-by":"crossref","first-page":"160","DOI":"10.2174\/1874210601812010160","article-title":"In vitro evaluation of the marginal fit and internal adaptation of zirconia and lithium disilicate single crowns: Micro-CT comparison between different manufacturing procedures","volume":"12","author":"Riccitiello","year":"2018","journal-title":"Open Dent J"},{"key":"R8-20261001","doi-asserted-by":"crossref","first-page":"374","DOI":"10.2186\/jpr.JPR_D_21_00081","article-title":"Clinical performance of monolithic CAD\/CAM tooth-supported zirconia restorations: Systematic review and meta-analysis","volume":"66","author":"Leit\u00e3o","year":"2022","journal-title":"J Prosthodont Res"},{"key":"R9-20261001","doi-asserted-by":"crossref","first-page":"331","DOI":"10.2186\/jpr.JPR_D_24_00183","article-title":"Outcomes of surveyed monolithic CAD\/CAM zirconia crowns for removable partial denture abutments: A 7-year clinical study","volume":"69","author":"Aziz","year":"2025","journal-title":"J Prosthodont Res"},{"key":"R10-20261001","first-page":"68","article-title":"Marginal Adaptation and Internal Fit of All Ceramic Crowns Fabricated with Pressed Versus Milled Zirconia Reinforced Lithium Silicate (An In-vitro study)","volume":"6","author":"Fahmi","year":"2022","journal-title":"Acta Sci Dent Sci"},{"key":"R11-20261001","doi-asserted-by":"crossref","first-page":"105089","DOI":"10.1016\/j.jdent.2024.105089","article-title":"Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: A systematic review and meta-analysis of in vitro studies","volume":"147","author":"Silva","year":"2024","journal-title":"J Dent"},{"key":"R12-20261001","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1186\/s12903-023-03184-8","article-title":"Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns","volume":"23","author":"Refaie","year":"2023","journal-title":"BMC Oral Health"},{"key":"R13-20261001","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1016\/j.prosdent.2016.09.011","article-title":"In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems","volume":"117","author":"Hamza","year":"2017","journal-title":"J Prosthet Dent"},{"key":"R14-20261001","doi-asserted-by":"crossref","first-page":"421","DOI":"10.2147\/CCIDE.S332944","article-title":"Fabrication of zirconia abutment crown and clasp under existing removable partial denture using CAD\/CAM technology","volume":"13","author":"Tasaka","year":"2021","journal-title":"Clin Cosmet Investig Dent"},{"key":"R15-20261001","doi-asserted-by":"crossref","first-page":"1","DOI":"10.25130\/tjds.12.1.1","article-title":"A Comparative Evaluation of Marginal and Internal Fitness of Zirconia Monolithic Crown Fabricated with Different CAD\/CAM Systems: (In Vitro Study)","volume":"12","author":"Assi","year":"2024","journal-title":"Tikrit J Dent Sci"},{"key":"R16-20261001","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.prosdent.2018.04.012","article-title":"Trueness analysis of zirconia crowns fabricated with 3-dimensional printing","volume":"121","author":"Wang","year":"2019","journal-title":"J Prosthet Dent"},{"key":"R17-20261001","doi-asserted-by":"crossref","first-page":"4591","DOI":"10.52711\/0974-360X.2023.00747","article-title":"Experimental Study to Evaluate the Internal Fit between Computer Aided Designing\/Computer Aided Manufactured (CAD-CAM) Zirconia Coping and Pressable Ceramic Coping","volume":"16","author":"Mohamed","year":"2023","journal-title":"Res J Pharm Technol"},{"key":"R18-20261001","doi-asserted-by":"crossref","first-page":"45","DOI":"10.4103\/tdj.tdj_18_19","article-title":"Influence of fabrication techniques on vertical marginal gap distance and internal adaptation of zirconia-reinforced lithium silicate all-ceramic crowns","volume":"17","author":"Asaad","year":"2020","journal-title":"Tanta Dent J"},{"key":"R19-20261001","doi-asserted-by":"crossref","first-page":"3330","DOI":"10.3390\/jcm13113330","article-title":"Three Self-Adhesive Resin Cements and Their Influence on the Marginal Adaptation of Zirconia-Reinforced Lithium Silicate Single Crowns: An In Vitro Scanning Electron Microscope Evaluation","volume":"13","author":"Shely","year":"2024","journal-title":"J Clin Med"},{"key":"R20-20261001","first-page":"1108","article-title":"Fracture resistance of monolithic gradient zirconia crowns with different finish line designs and cement spaces","volume":"19","author":"AbdElaziz","year":"2024","journal-title":"J Taibah Univ Med Sci"},{"key":"R21-20261001","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1186\/s12903-023-03365-5","article-title":"Fracture resistance of monolithic translucent zirconia crown bonded with different self-adhesive resin cement: Influence of MDP-containing zirconia primer after aging","volume":"23","author":"Tyor","year":"2023","journal-title":"BMC Oral Health"},{"key":"R22-20261001","doi-asserted-by":"crossref","first-page":"79","DOI":"10.4047\/jap.2018.10.2.79","article-title":"In-vitro performance and fracture strength of thin monolithic zirconia crowns","volume":"10","author":"Weigl","year":"2018","journal-title":"J Adv Prosthodont"},{"key":"R23-20261001","doi-asserted-by":"crossref","first-page":"61","DOI":"10.3390\/dj12030061","article-title":"SEM evaluation of the marginal gap of zirconia-reinforced lithium silicate full crowns and the effect of post crystallization: An in vitro study","volume":"12","author":"Shely","year":"2024","journal-title":"Dent J (Basel)"},{"key":"R24-20261001","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.prosdent.2014.03.017","article-title":"Marginal and internal adaptation of ceramic crown restorations fabricated with CAD\/CAM technology and the heat-press technique","volume":"112","author":"Mously","year":"2014","journal-title":"J Prosthet Dent"},{"key":"R25-20261001","doi-asserted-by":"crossref","first-page":"4239","DOI":"10.3390\/ma13194239","article-title":"In Vitro Study of Comparative Evaluation of Marginal and Internal Fit between Heat-Pressed and CAD-CAM Monolithic Glass-Ceramic Restorations after Thermal Aging","volume":"13","author":"Vasiliu","year":"2020","journal-title":"Materials (Basel)"},{"key":"R26-20261001","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.prosdent.2013.12.002","article-title":"A comparison of the marginal fit of crowns fabricated with digital and conventional methods","volume":"112","author":"Ng","year":"2014","journal-title":"J Prosthet Dent"},{"key":"R27-20261001","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3390\/prosthesis5010003","article-title":"Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study","volume":"5","author":"\u00c7in","year":"2023","journal-title":"Prosthesis"},{"key":"R28-20261001","doi-asserted-by":"crossref","first-page":"e31","DOI":"10.4317\/medoral.55946","article-title":"Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD\/CAM crowns","volume":"12","author":"Paul","year":"2020","journal-title":"J Clin Exp Dent"}],"container-title":["The Journal of Indian Prosthodontic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_289_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T13:19:54Z","timestamp":1790860794000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_289_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jips.jips_289_26","relation":{},"ISSN":["0972-4052","1998-4057"],"issn-type":[{"value":"0972-4052","type":"print"},{"value":"1998-4057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"2026-06-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}