{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T17:26:50Z","timestamp":1786728410073,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>To assess the effectiveness of this Implant T Stabilizing plate in distributing the masticatory stress around the implant placed immediately after maxillary sinus lifting in cases with reduced remaining bone height (3 mm).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>\n                      <jats:italic toggle=\"yes\">In vitro<\/jats:italic>\n                      experimental study.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Two 3D finite element maxillary models with implant placement in 16 region were designed, one without an implant T stabilizing plate and another with an implant T stabilizing plate. Interim removable partial denture with soft liner replacing 16 and 17 was also designed for both models over which the masticatory force of 12 kg was applied. The maximum principal stress generated around the implant and surrounding bone in both models was measured.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>Statistical analysis was done by using MedCalc stratistical software \u2013 version 23.1.7 in which \u2018Receiver Operating Characteristic Curve\u2019 analysis was performed to check for the sensitivity and specificity of the material used.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The maximum principal stress around the implant and the cortical bone in working model 1 (without the ITS plate) was 5.2972 and 5.2387 mega pascal respectively. The maximum principal stress around the implant and the cortical bone in working model 2 (with ITS plate) was 1.1663 and 4.5568 mega pascal respectively. In the working model 2, the Implant T stabilizing plate absorbs maximum stress of 10.022 mega pascal.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The implant T stabilizing (ITS) plate to the implant placed immediately after maxillary sinus lifting absorbs the maximum stress there by reducing the stress around the implant and surrounding bone even in cases of minimal remaining bone height.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jips.jips_409_24","type":"journal-article","created":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T07:00:14Z","timestamp":1744354814000},"page":"138-143","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Effectiveness of the implant stabilizing plate on the stress distribution around the implant placed immediately after maxillary sinus lifting: A finite element study"],"prefix":"10.4103","volume":"25","author":[{"given":"V. R. Arun","family":"Kumar","sequence":"first","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India"},{"name":"PhD Scholar, Department of Prosthodontics and Crown and Bridge, Indira Gandhi Institute of Dental Sciences, Sri Balaji Vidyapeeth, Puducherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shivasakthy","family":"Manivasakan","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Indira Gandhi Institute of Dental Sciences, Sri Balaji Vidyapeeth, Puducherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Prabhu","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Livingstone","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Crown and Bridge, Indira Gandhi Institute of Dental Sciences, Sri Balaji Vidyapeeth, Puducherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Shanti","family":"Swarup","sequence":"additional","affiliation":[{"name":"Department of Pedodontics and Preventive Dentistry, Tamil Nadu Government Dental College and Hospital, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,11]]},"reference":[{"key":"R1-20250714","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1038\/s41368-023-00248-x","article-title":"Maxillary sinus floor augmentation: A review of current evidence on anatomical factors and a decision tree","volume":"15","author":"Lyu","year":"2023","journal-title":"Int J Oral Sci"},{"key":"R2-20250714","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1007\/s12663-022-01785-4","article-title":"Radiological evaluation and biomechanical stability of implants simultaneously placed at the sites with sole advanced platelet-rich fibrin (A-PRF) grafted sinus floor","volume":"22","author":"Erdem","year":"2023","journal-title":"J Maxillofac Oral Surg"},{"key":"R3-20250714","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1111\/prd.12414","article-title":"Complications in sinus lifting procedures: Classification and management","volume":"88","author":"Molina","year":"2022","journal-title":"Periodontol 2000"},{"key":"R4-20250714","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1097\/ID.0b013e31822b9d2d","article-title":"Dental implant migration in grafted maxillary sinus","volume":"20","author":"Galindo-Moreno","year":"2011","journal-title":"Implant Dent"},{"key":"R5-20250714","doi-asserted-by":"crossref","first-page":"104137","DOI":"10.1016\/j.jdent.2022.104137","article-title":"Guided implant surgery and sinus lift in severely resorbed maxillae: A retrospective clinical study with up to 10 years of follow-up","volume":"121","author":"Pistilli","year":"2022","journal-title":"J Dent"},{"key":"R6-20250714","first-page":"e231","article-title":"Influence of thickness and area of reline on the stress distribution in peri-implant bone during the healing period: A three-dimensional finite element analysis","volume":"60","author":"dos Santos","year":"2012","journal-title":"Gen Dent"},{"key":"R7-20250714","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1097\/ID.0000000000000408","article-title":"Implants displaced into the maxillary sinus: A systematic review","volume":"25","author":"Jeong","year":"2016","journal-title":"Implant Dent"},{"key":"R8-20250714","first-page":"1","article-title":"Biomechanical factors that influence the bone-implant-interface","volume":"3","author":"Elsayed","year":"2019","journal-title":"Res Rep Oral Maxillofac Surg"},{"key":"R9-20250714","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1111\/jopr.12421","article-title":"Interim prosthesis options for dental implants","volume":"26","author":"Siadat","year":"2017","journal-title":"J Prosthodont"},{"key":"R10-20250714","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1007\/s00784-020-03432-z","article-title":"Effect of bone quality and quantity on the primary stability of dental implants in a simulated bicortical placement","volume":"25","author":"Rues","year":"2021","journal-title":"Clin Oral Investig"},{"key":"R11-20250714","doi-asserted-by":"crossref","first-page":"4335","DOI":"10.1038\/s41598-020-60735-7","article-title":"The interplay between bone healing and remodeling around dental implants","volume":"10","author":"Irandoust","year":"2020","journal-title":"Sci Rep"},{"key":"R12-20250714","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1097\/00008505-200201000-00014","article-title":"Enhancement of primary stability of dental implants using cortical satellite implants","volume":"11","author":"Engelke","year":"2002","journal-title":"Implant Dent"},{"key":"R13-20250714","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1067\/mpr.2001.115251","article-title":"Application of finite element analysis in implant dentistry: A review of the literature","volume":"85","author":"Geng","year":"2001","journal-title":"J Prosthet Dent"},{"key":"R14-20250714","doi-asserted-by":"crossref","first-page":"11401","DOI":"10.3390\/ijerph182111401","article-title":"The effects of wearing a removable-partial-denture on the bite forces: A cross-sectional study","volume":"18","author":"Vozza","year":"2021","journal-title":"Int J Environ Res Public Health"},{"key":"R15-20250714","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.tripleo.2010.03.028","article-title":"Biomechanical evaluation of a T-shaped miniplate fixation of a modified sagittal split ramus osteotomy with buccal step, a new technique for mandibular orthognathic surgery","volume":"111","author":"Aymach","year":"2011","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"}],"container-title":["The Journal of Indian Prosthodontic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_409_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T16:26:42Z","timestamp":1786724802000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_409_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jips.jips_409_24","relation":{},"ISSN":["0972-4052","1998-4057"],"issn-type":[{"value":"0972-4052","type":"print"},{"value":"1998-4057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-10-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}