{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T20:25:03Z","timestamp":1788207903349,"version":"build-2803163510"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>Since the advent of radiotherapy, the success rate of head and neck cancer treatment has increased significantly. However, when the tissue tolerance level is exceeded, unnecessary and uncontrolled exposure to radiation is considered detrimental. Such problems remain difficult to prevent and manage. The aim of the study to evaluate and compare the degree of attenuation of therapeutic radiation using four different radiation shielding materials of varying thickness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Setting and Design:<\/jats:title>\n                    <jats:p>\n                      <jats:italic toggle=\"yes\">In vitro<\/jats:italic>\n                      experimental study.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      The samples were divided into four groups based on the different radiation shielding materials of thickness 3mm and 5mm. The materials are Lead (Pb), Silver-tin alloy (Ag-Sn) with Polyvinylsiloxane (PVS), Polymethylmethacrylate (PMMA) with Barium sulphate (BaSO\n                      <jats:sub>4<\/jats:sub>\n                      ), and a combination of Ag-Sn with PVS and PMMA with BaSO\n                      <jats:sub>4<\/jats:sub>\n                      which was exposed to radiation. The radiation dose measurements were recorded and the radiation attenuation properties of the shielding materials were evaluated. Among all of the shielding materials the most efficient material under consideration is determined.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>\n                      One-way ANOVA followed by\n                      <jats:italic toggle=\"yes\">post hoc<\/jats:italic>\n                      test was used to compare the means of all four groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A statistically significant difference between groups was found by a one-way ANOVA with a\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001. In the\n                      <jats:italic toggle=\"yes\">post hoc<\/jats:italic>\n                      test, statistically significant findings were obtained with a\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.05 when comparing the variation values of 3mm and 5mm thickness between each group and other groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      The shielding materials results in significant reductions in radiation dosage. It was concluded that the combinations of Ag-Sn alloy with PVS, and PMMA with BaSO\n                      <jats:sub>4<\/jats:sub>\n                      of thickness 5 mm had a good shielding effect.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jips.jips_570_23","type":"journal-article","created":{"date-parts":[[2024,10,15]],"date-time":"2024-10-15T03:00:28Z","timestamp":1728961228000},"page":"381-386","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Assessment of different shielding materials for radiation therapy of maxillofacial tumors \u2013 An in vitro study"],"prefix":"10.4103","volume":"24","author":[{"given":"K Kasim","family":"Mohamed","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K Satish","family":"Srinivas","sequence":"additional","affiliation":[{"name":"Department of Radiatian Oncology, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madhankumar","family":"Seenivasan","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annapoorani","family":"Babu","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,10,15]]},"reference":[{"key":"R1-20260427","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1902\/jop.1965.36.6.478","article-title":"Radiation therapy of oral carcinoma. I. Effects on oral tissues and management of the periodontium","volume":"36","author":"Silverman","year":"1965","journal-title":"J Periodontol"},{"key":"R2-20260427","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1002\/jso.2930300109","article-title":"Clinical uses of prosthetic devices in brachiotherapy for oral cavity tumors","volume":"30","author":"Sela","year":"1985","journal-title":"J Surg Oncol"},{"key":"R3-20260427","first-page":"1358","article-title":"Clinical demonstration of various radiation stents- An overview","volume":"8","author":"Jain","year":"2016","journal-title":"J Pharm Sci Res"},{"key":"R4-20260427","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/0360-3016(82)90076-1","article-title":"The use of acrylic resin oral prosthesis in radiation therapy of oral cavity and paranasal sinus cancer","volume":"8","author":"Cheng","year":"1982","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R5-20260427","doi-asserted-by":"crossref","first-page":"160","DOI":"10.4103\/0975-5950.183870","article-title":"Radiation-induced dental caries, prevention and treatment \u2013 A systematic review","volume":"6","author":"Gupta","year":"2015","journal-title":"Natl J Maxillofac Surg"},{"key":"R6-20260427","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1016\/0022-3913(83)90314-1","article-title":"Complications of head and neck radiation therapy and their management","volume":"49","author":"Engelmeier","year":"1983","journal-title":"J Prosthet Dent"},{"key":"R7-20260427","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1111\/j.1532-849X.1994.tb00155.x","article-title":"A convenient method for guarding against localized mucositis during radiation therapy","volume":"3","author":"Wang","year":"1994","journal-title":"J Prosthodont"},{"key":"R8-20260427","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1177\/154411130301400305","article-title":"Oral sequelae of head and neck radiotherapy","volume":"14","author":"Vissink","year":"2003","journal-title":"Crit Rev Oral Biol Med"},{"key":"R9-20260427","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/0360-3016(92)90023-B","article-title":"Devices valuable in head and neck radiotherapy","volume":"23","author":"Kaanders","year":"1992","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R10-20260427","doi-asserted-by":"crossref","first-page":"39","DOI":"10.4103\/0019-509X.98917","article-title":"Scope of prosthodontic services for patients with head and neck cancer","volume":"49","author":"Mantri","year":"2012","journal-title":"Indian J Cancer"},{"key":"R11-20260427","first-page":"38","article-title":"Prosthodontic stents - A bulwark against radiation","volume":"4","author":"Jabeen","year":"2018","journal-title":"IP Ann Prosthodont Restor Dent"},{"key":"R12-20260427","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1118\/1.596724","article-title":"Metal-polysiloxane shields for radiation therapy of maxillo-facial tumors","volume":"18","author":"Farahani","year":"1991","journal-title":"Med Phys"},{"key":"R13-20260427","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.4103\/0973-1482.144688","article-title":"Cerrobend shielding stents for buccal carcinoma patients","volume":"12","author":"Yangchen","year":"2016","journal-title":"J Cancer Res Ther"},{"key":"R14-20260427","doi-asserted-by":"crossref","first-page":"151","DOI":"10.4103\/0972-0464.176157","article-title":"Attenuation of 60 Co gamma rays by barium acrylic resin composite shields","volume":"38","author":"Abdulla","year":"2015","journal-title":"Radiat Prot Environ"},{"key":"R15-20260427","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1089\/ars.2013.5489","article-title":"Effects of ionizing radiation on biological molecules \u2013 Mechanisms of damage and emerging methods of detection","volume":"21","author":"Reisz","year":"2014","journal-title":"Antioxid Redox Signal"},{"key":"R16-20260427","doi-asserted-by":"crossref","first-page":"2057","DOI":"10.1007\/s10311-021-01189-9","article-title":"Polymeric composite materials for radiation shielding: A review","volume":"19","author":"More","year":"2021","journal-title":"Environ Chem Lett"},{"key":"R17-20260427","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1118\/1.596724","article-title":"Metal-polysiloxane shields for radiation therapy of maxillo-facial tumors","volume":"18","author":"Farahani","year":"1989","journal-title":"Med Phys"},{"key":"R18-20260427","doi-asserted-by":"crossref","first-page":"110","DOI":"10.4103\/2228-7477.157617","article-title":"Designing and dosimetry of a shield for photon fields of radiation therapy in oral cavity cancer","volume":"5","author":"Jabbari","year":"2015","journal-title":"J Med Signals Sens"},{"key":"R19-20260427","doi-asserted-by":"crossref","first-page":"E213","DOI":"10.1002\/hed.23028","article-title":"Impact of intraoral stent on the side effects of radiotherapy for oral cancer","volume":"35","author":"Verrone","year":"2013","journal-title":"Head Neck"},{"key":"R20-20260427","first-page":"1","article-title":"Materials selection for constructing an intraoral stent used in radiotherapy: Analysis of density and structure","volume":"16","author":"Martins","year":"2016","journal-title":"J Adv Med Med Res"}],"container-title":["The Journal of Indian Prosthodontic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_570_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:54:22Z","timestamp":1786647262000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_570_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jips.jips_570_23","relation":{},"ISSN":["0972-4052","1998-4057"],"issn-type":[{"value":"0972-4052","type":"print"},{"value":"1998-4057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"2023-12-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}