{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T20:39:46Z","timestamp":1786653586783,"version":"build-2736575974"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design\/computer-aided manufacturing (CAD\/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>\n                      The study employed an\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone. The dies were divided into two groups: Group-A (PEEK) copings and Group-B (zirconia) copings. All copings were fabricated using a CAD\/CAM system. Vertical marginal accuracy was assessed with a stereomicroscope and image analysis software at \u00d720 magnification. The marginal ga\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      values were subjected to a student (independent)\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test for statistical analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>\n                      The statistical analysis involved a student (independent)\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test to compare the marginal ga\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      values between Group A (PEEK) and Group B (zirconia).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean marginal discrepancy for Group A (PEEK) and Group B (zirconia) was 92.84 \u03bcm \u00b1 3.48 \u03bcm and 63.12 \u03bcm \u00b1 31.47 \u03bcm, respectively. A statistically significant variation (\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      = 3.635,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001) between the groups was observed, indicating better marginal accuracy with zirconia copings compared to PEEK copings.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      Both PEEK and zirconia copings demonstrated vertical marginal discrepancies within the clinically acceptable limit of &lt;120 \u03bcm. However, zirconia copings exhibited superior marginal accuracy in this\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      study.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jips.jips_8_24","type":"journal-article","created":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T09:04:48Z","timestamp":1735895088000},"page":"95-101","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design\/computer-aided manufacturing technique: An in vitro study"],"prefix":"10.4103","volume":"25","author":[{"given":"Manish","family":"Jangade","sequence":"first","affiliation":[{"name":"Department of Prosthodontics (Unit of Dentistry), Smt. Indira Gandhi Memorial Government Medical College, Kanker, Chhattishgarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranu","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Rungta College of Dental Sciences and Research, Bhilai, Chhattishgarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nishanth A.","family":"Sudharson","sequence":"additional","affiliation":[{"name":"Division of Prosthodontics, Christian Dental College, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj","family":"Jain","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Chhattisgarh Dental College and Hospital, Rajnandgaon, Chhattishgarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shailendra Kumar","family":"Sahu","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Chhattisgarh Dental College and Hospital, Rajnandgaon, Chhattishgarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anurag","family":"Dani","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Chhattisgarh Dental College and Hospital, Rajnandgaon, Chhattishgarh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,1,3]]},"reference":[{"key":"R1-20250714","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jpor.2014.07.003","article-title":"Ceramic dental biomaterials and CAD\/CAM technology: State of the art","volume":"58","author":"Li","year":"2014","journal-title":"J Prosthodont Res"},{"key":"R2-20250714","first-page":"482","article-title":"Panorama of dental CAD\/CAM restorative systems","volume":"29","author":"Liu","year":"2008","journal-title":"Compend Contin Educ Dent"},{"key":"R3-20250714","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jpor.2013.09.001","article-title":"Current status of zirconia restoration","volume":"57","author":"Miyazaki","year":"2013","journal-title":"J Prosthodont Res"},{"key":"R4-20250714","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1111\/jopr.12001","article-title":"Implant-supported fixed dental prostheses with CAD\/CAM-fabricated porcelain crown and zirconia-based framework","volume":"22","author":"Takaba","year":"2013","journal-title":"J Prosthodont"},{"key":"R5-20250714","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1111\/jopr.12006","article-title":"Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: A literature review","volume":"22","author":"Nawafleh","year":"2013","journal-title":"J Prosthodont"},{"key":"R6-20250714","first-page":"75","volume":"65","author":"Bader","year":"1991","journal-title":"Effect of crown margins on periodontal conditions in regularly attending patients"},{"key":"R7-20250714","doi-asserted-by":"crossref","first-page":"15","DOI":"10.3390\/jfb13010015","article-title":"Fixed prosthetic restorations and periodontal health: A narrative review","volume":"13","author":"Srimaneepong","year":"2022","journal-title":"J Funct Biomater"},{"key":"R8-20250714","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/S0022-3913(13)60020-7","article-title":"Accuracy of ceramic restorations made with two CAD\/CAM systems","volume":"109","author":"Hamza","year":"2013","journal-title":"J Prosthet Dent"},{"key":"R9-20250714","doi-asserted-by":"crossref","first-page":"e91","DOI":"10.1016\/j.dental.2013.04.007","article-title":"An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system","volume":"29","author":"Kim","year":"2013","journal-title":"Dent Mater"},{"key":"R10-20250714","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.dental.2011.12.008","article-title":"Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: A three-dimensional analysis of accuracy and reproducibility","volume":"28","author":"Schaefer","year":"2012","journal-title":"Dent Mater"},{"key":"R11-20250714","doi-asserted-by":"crossref","first-page":"1425","DOI":"10.1016\/j.prosdent.2014.05.012","article-title":"A 3-dimensional accuracy analysis of chairside CAD\/CAM milling processes","volume":"112","author":"Bosch","year":"2014","journal-title":"J Prosthet Dent"},{"key":"R12-20250714","doi-asserted-by":"crossref","first-page":"S1199","DOI":"10.4103\/jpbs.jpbs_328_21","article-title":"Comparison of marginal fit and internal adaptation of copings fabricated with polyetheretherketone and zirconia\u2013an in vitro study","volume":"13","author":"Amalorpavam","year":"2021","journal-title":"J Pharm Bioallied Sci"},{"key":"R13-20250714","doi-asserted-by":"crossref","first-page":"701","DOI":"10.4103\/njcp.njcp_701_22","article-title":"In vitro evaluation of marginal adaptation of polyether ether ketone and zirconia copings","volume":"26","author":"Chouksey","year":"2023","journal-title":"Niger J Clin Pract"},{"key":"R14-20250714","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1016\/j.dental.2011.09.006","article-title":"Three-dimensional fit of CAD\/CAM-made zirconia copings","volume":"27","author":"Moldovan","year":"2011","journal-title":"Dent Mater"},{"key":"R15-20250714","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.dental.2008.01.008","article-title":"Computer aided analysis of digitized dental stone replicas by dental CAD\/CAM technology","volume":"24","author":"Persson","year":"2008","journal-title":"Dent Mater"},{"key":"R16-20250714","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.compbiomed.2006.05.006","article-title":"Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD\/CAM technology","volume":"37","author":"Rudolph","year":"2007","journal-title":"Comput Biol Med"},{"key":"R17-20250714","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.dental.2013.04.018","article-title":"Effect of CNC-milling on the marginal and internal fit of dental ceramics: A pilot study","volume":"29","author":"Schaefer","year":"2013","journal-title":"Dent Mater"},{"key":"R18-20250714","doi-asserted-by":"crossref","first-page":"555","DOI":"10.4097\/kjae.2016.69.6.555","article-title":"Alternatives to P value: Confidence interval and effect size","volume":"69","author":"Lee","year":"2016","journal-title":"Korean J Anesthesiol"},{"key":"R19-20250714","doi-asserted-by":"crossref","first-page":"820","DOI":"10.4012\/dmj.26.820","article-title":"Effect of sintering on the marginal and internal fit of CAD\/CAM-fabricated zirconia frameworks","volume":"26","author":"Kunii","year":"2007","journal-title":"Dent Mater J"},{"key":"R20-20250714","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0022-3913(07)60124-3","article-title":"Current ceramic materials and systems with clinical recommendations: A systematic review","volume":"98","author":"Conrad","year":"2007","journal-title":"J Prosthet Dent"},{"key":"R21-20250714","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.21608\/edj.2019.72636","article-title":"Marginal fit of polyetheretherketone single crown copings obtained using different fabrication techniques","volume":"65","author":"Attia","year":"2019","journal-title":"Egypt Dent J"},{"key":"R22-20250714","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1177\/20501684221132976","article-title":"CAD\/CAM technology for fabrication of reduction guide for RPD parallel guiding planes preparation: A dental technique","volume":"11","author":"Carvalho","year":"2022","journal-title":"Prim Dent J"},{"key":"R23-20250714","first-page":"343","article-title":"Understanding dental CAD\/CAM for restorations \u2013 Accuracy from a mechanical engineering viewpoint","volume":"18","author":"Tapie","year":"2015","journal-title":"Int J Comput Dent"},{"key":"R24-20250714","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.prosdent.2024.02.021","article-title":"Influence of CAD-CAM milling strategies on the outcome of indirect restorations: A scoping review","volume":"131","author":"Pilecco","year":"2024","journal-title":"J Prosthet Dent"},{"key":"R25-20250714","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1016\/j.jds.2021.04.005","article-title":"Tooth preparation, digital design and milling process considerations for CAD\/CAM crowns: Understanding the transition from analog to digital workflow","volume":"16","author":"Turkyilmaz","year":"2021","journal-title":"J Dent Sci"},{"key":"R26-20250714","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1186\/s12903-023-03247-w","article-title":"Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering","volume":"23","author":"Emam","year":"2023","journal-title":"BMC Oral Health"},{"key":"R27-20250714","doi-asserted-by":"crossref","first-page":"361","DOI":"10.11607\/ijp.6157","article-title":"Comparison of marginal adaptation of different implant-supported metal-free frameworks before and after cementation","volume":"32","author":"Zeighami","year":"2019","journal-title":"Int J Prosthodont"}],"container-title":["The Journal of Indian Prosthodontic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_8_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:39:38Z","timestamp":1786649978000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jips.jips_8_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jips.jips_8_24","relation":{},"ISSN":["0972-4052","1998-4057"],"issn-type":[{"value":"0972-4052","type":"print"},{"value":"1998-4057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2024-01-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}