{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T20:10:22Z","timestamp":1791576622078,"version":"4.3.4"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract:<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Dental implants have become a widely accepted solution for the replacement of missing teeth, offering functional and esthetic benefits. The long-term success of dental implants largely depends on the distribution of stresses in the surrounding bone, as excessive stress can lead to bone resorption and implant failure. Finite element analysis (FEA) is a powerful tool that allows for the simulation of mechanical behavior under functional loading, providing insights into stress patterns and implant performance in various anatomical and prosthetic configurations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>The aim of the study was to analyze stress distribution around conventional and basal dental implants placed in the posterior region of the mandible using FEA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>The finite element model simulated a partially edentulous posterior mandibular segment where the mandibular second premolar and first molar were missing. Two dental implants were placed in the posterior mandible to simulate clinical rehabilitation of this region. Three-dimensional models were developed using cone beam computed tomography scans, and FEA was performed with ANSYS Workbench 18.1. Two models were analyzed: Model 1: conventional implant (4.1 mm \u00d7 8 mm) in 10-mm residual bone height and Model 2: basal implant (3.5 mm \u00d7 16 mm) in 8-mm residual bone height. Stress distribution was assessed under masticatory loading conditions to evaluate implant stability and stress accumulation in surrounding bone structures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The study was designed as a comparative FEA evaluating stress distribution between conventional and basal implant systems placed in the posterior mandible under identical loading conditions. Model 2 (basal implant) exhibited greater deflection (13 \u03bcm), which may compromise implant stability. Model 1 (conventional implant) demonstrated higher stress accumulation in the cortical bone (34.71 MPa).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The present FEA demonstrates that although basal implants showed slightly lower crestal bone stress, the increased deformation observed may influence long-term biomechanical stability under functional loading conditions. Hence, Model 1 (conventional implant) is the preferred choice for clinical applications, offering better stability and longevity compared to Model 2.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jisp.jisp_131_25","type":"journal-article","created":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T10:00:51Z","timestamp":1784714451000},"page":"309-313","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Analysis of stress distribution around conventional and basal dental implants in the posterior mandible: A finite element study"],"prefix":"10.4103","volume":"30","author":[{"given":"Gayathri N.","family":"Meikandan","sequence":"first","affiliation":[{"name":"Department of Periodontology, Vinayaka Mission\u2019s Sankarachariyar Dental College, Vinayaka Mission\u2019s Research Foundation (Deemed to be University), Salem, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Jayachandran","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Vinayaka Mission\u2019s Sankarachariyar Dental College, Vinayaka Mission\u2019s Research Foundation (Deemed to be University), Salem, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Jayaprakash","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Sree Sakthi Engineering College, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Saranyan","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Vinayaka Mission\u2019s Sankarachariyar Dental College, Vinayaka Mission\u2019s Research Foundation (Deemed to be University), Salem, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priya","family":"Kesavan","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Vinayaka Mission\u2019s Sankarachariyar Dental College, Vinayaka Mission\u2019s Research Foundation (Deemed to be University), Salem, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V. M.","family":"Deepa","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Vinayaka Mission\u2019s Sankarachariyar Dental College, Vinayaka Mission\u2019s Research Foundation (Deemed to be University), Salem, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,22]]},"reference":[{"key":"R1-20260722","doi-asserted-by":"crossref","first-page":"941","DOI":"10.14219\/jada.2013.48","article-title":"The relationship between various parameters of complete denture quality and patients'satisfaction","volume":"145","author":"Alfadda","year":"2014","journal-title":"J Am Dent Assoc"},{"key":"R2-20260722","doi-asserted-by":"crossref","first-page":"82","DOI":"10.4015\/S1016237203000134","article-title":"Finite element analysis of a dental implant","volume":"25","author":"Huang","year":"2003","journal-title":"Biomed Eng Appl Basis Commun"},{"key":"R3-20260722","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1034\/j.1600-0501.2001.012003207.x","article-title":"The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study","volume":"12","author":"Duyck","year":"2001","journal-title":"Clin Oral Implants Res"},{"key":"R4-20260722","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.prosdent.2004.10.001","article-title":"Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor","volume":"93","author":"Koca","year":"2005","journal-title":"J Prosthet Dent"},{"key":"R5-20260722","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/S0022-3913(09)60079-2","article-title":"The dynamic nature of implant loading","volume":"101","author":"Wang","year":"2009","journal-title":"J Prosthetic Dent"},{"key":"R6-20260722","first-page":"1","article-title":"Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period","volume":"16","author":"Br\u00e5nemark","year":"1977","journal-title":"Scand J Plast Reconstr Surg Suppl"},{"key":"R7-20260722","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1563\/1548-1336(2000)026<0077:TROTFE>2.3.CO;2","article-title":"Role of the finite element model in dental implants","volume":"26","author":"DeTolla","year":"2000","journal-title":"J Oral Implantol"},{"key":"R8-20260722","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/0003-9969(93)90185-O","article-title":"A three-dimensional, finite element analysis of bone around dental implants in an edentulous human mandible","volume":"38","author":"Heijer","year":"1993","journal-title":"Arch Oral Biol"},{"key":"R9-20260722","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s007840050054","article-title":"Failure of oral implants: Aetiology, symptoms and influencing factors","volume":"2","author":"Duyck","year":"1998","journal-title":"Clin Oral Investig"},{"key":"R10-20260722","first-page":"536","article-title":"Oral implant surfaces: Part 1-review focusing on topographic and chemical properties of different surfaces and in vivo responses to them","volume":"17","author":"Albrektsson","year":"2004","journal-title":"Int J Prosthodont"},{"key":"R11-20260722","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/S0022-3913(98)70009-5","article-title":"Biologic determinants of bone formation for osseointegration: Clues for future clinical improvements","volume":"80","author":"Cooper","year":"1998","journal-title":"J Prosthet Dent"},{"key":"R12-20260722","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1002\/jbm.820250708","article-title":"Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs","volume":"25","author":"Buser","year":"1991","journal-title":"J Biomed Mater Res"},{"key":"R13-20260722","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1046\/j.0909-8836..t01-2-.x","article-title":"Biological factors contributing","volume":"106","author":"Esposito","year":"1998","journal-title":"Euro J Oral Sci"},{"key":"R14-20260722","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1615\/IntJMultCompEng.2022043707","article-title":"Biomechanical evaluation of marginal bone loss in the surrounding bone under different loading: 3D finite element analysis study","volume":"20","author":"Ouldyerou","year":"2022","journal-title":"Int J Multiscale Comput Eng"},{"key":"R15-20260722","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/0022-3913(92)90293-J","article-title":"Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible","volume":"68","author":"Meijer","year":"1992","journal-title":"J Prosthet Dent"},{"key":"R16-20260722","first-page":"130","article-title":"Comparison of short and standard implants in the posterior mandible: A 3D analysis using finite element method","volume":"15","author":"Geramy","year":"2018","journal-title":"J Dent (Tehran)"},{"key":"R17-20260722","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/00029330-200602020-00007","article-title":"Three-dimensional finite element analysis of weakened roots restored with different cements in combination with titanium alloy posts","volume":"119","author":"Li","year":"2006","journal-title":"Chin Med J (Engl)"},{"key":"R18-20260722","first-page":"983103","article-title":"Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: A three-dimensional finite element analysis","author":"Ma","year":"2014","journal-title":"Biomed Res Int 2014"},{"key":"R19-20260722","doi-asserted-by":"crossref","first-page":"1985","DOI":"10.4028\/www.scientific.net\/AMR.941-944.1985","article-title":"Machinability assessment of titanium alloy Ti-6Al-4V for biomedical applications","volume":"941","author":"Polishetty","year":"2014","journal-title":"Adv Mater Res"},{"key":"R20-20260722","first-page":"2785863","article-title":"Mechanical characterisation and biomechanical and biological behaviours of Ti-Zr binary-alloy dental implants","author":"Brizuela-Velasco","year":"2017","journal-title":"Biomed Res Int 2017"},{"key":"R21-20260722","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.matpr.2020.05.543","article-title":"Mechanical properties and corrosion resistance of cobalt-chrome alloy fabricated using additive manufacturing","volume":"29","author":"Hong","year":"2020","journal-title":"Mater Today Proc"},{"key":"R22-20260722","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1177\/00220345920710050101","article-title":"Strengthening of feldspathic porcelain by ion exchange and tempering","volume":"71","author":"Anusavice","year":"1992","journal-title":"J Dent Res"},{"key":"R23-20260722","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/0003-9969(93)90185-O","article-title":"A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible","volume":"38","author":"Meijer","year":"1993","journal-title":"Arch Oral Biol"},{"key":"R24-20260722","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1067\/mpr.2001.115251","article-title":"Application of finite element analysis in implant dentistry: A review of the literature","volume":"85","author":"Geng","year":"2001","journal-title":"J Prosthet Dent"},{"key":"R25-20260722","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1034\/j.1600-0501.2003.140306.x","article-title":"A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysis","volume":"14","author":"Hansson","year":"2003","journal-title":"Clin Oral Implants Res"},{"key":"R26-20260722","doi-asserted-by":"crossref","first-page":"590","DOI":"10.4103\/jisp.jisp_585_22","article-title":"Evaluation and comparison of three-dimensional finite element analysis of stress distribution in immediately placed and loaded conventional and customized three-dimensional printed dental implants","volume":"27","author":"Saini","year":"2023","journal-title":"J Indian Soc Periodontol"},{"key":"R27-20260722","doi-asserted-by":"crossref","first-page":"78","DOI":"10.4103\/ams.ams_250_18","article-title":"Immediate functional loading: Results for the concept of the strategic implant(\u00ae)","volume":"9","author":"Lazarov","year":"2019","journal-title":"Ann Maxillofac Surg"},{"key":"R28-20260722","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/prd.12532","article-title":"Emerging factors affecting peri-implant bone metabolism","volume":"94","author":"Insua","year":"2024","journal-title":"Periodontol 2000"},{"key":"R29-20260722","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1111\/jopr.13005","article-title":"The effect of ceramic type and background color on shade reproducibility of all-ceramic restorations","volume":"29","author":"Al Hamad","year":"2020","journal-title":"J Prosthodont"}],"container-title":["Journal of Indian Society of Periodontology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.4103\/jisp.jisp_131_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T10:00:55Z","timestamp":1784714455000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.4103\/jisp.jisp_131_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jisp.jisp_131_25","relation":{},"ISSN":["0972-124X","0975-1580"],"issn-type":[{"value":"0972-124X","type":"print"},{"value":"0975-1580","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]},"assertion":[{"value":"2025-04-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-02","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}