{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,4]],"date-time":"2024-08-04T13:15:09Z","timestamp":1722777309141},"reference-count":7,"publisher":"Scientific Scholar","issue":"01","license":[{"start":{"date-parts":[[2020,2,19]],"date-time":"2020-02-19T00:00:00Z","timestamp":1582070400000},"content-version":"vor","delay-in-days":779,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Lab Physicians"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          BACKGROUND: Erycard 2.0 is a \u201cpoint-of-care\u201d device that is primarily being used for patient blood grouping before transfusion.<\/jats:p><jats:p>\n          MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff.<\/jats:p><jats:p>\n          RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique.<\/jats:p><jats:p>\n          CONCLUSION: Erycard 2.0 can be used as \u201cpoint-of-care\u201d device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.<\/jats:p>","DOI":"10.4103\/jlp.jlp_71_17","type":"journal-article","created":{"date-parts":[[2018,1,3]],"date-time":"2018-01-03T08:43:08Z","timestamp":1514968988000},"page":"080-084","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of new indigenous \u201cpoint\u2011of\u2011care\u201d ABO and Rh grouping device"],"prefix":"10.25259","volume":"10","author":[{"given":"Aseem Kumar","family":"Tiwari","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Divya","family":"Setya","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geet","family":"Aggarwal","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dinesh","family":"Arora","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ravi C.","family":"Dara","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Manipal Hospitals, Jaipur, Rajasthan, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ankita","family":"Ratan","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gunjan","family":"Bhardwaj","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Devi Prasad","family":"Acharya","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2020,2,19]]},"reference":[{"key":"key-10.4103\/0974-2727.222168-1","unstructured":"Prasad JP. Guidance Manual on \u201cABO and Rh Blood Grouping\u201d. Document ID No. NIB\/BRL\/GM\/02. National Institute of Biologicals (Ministry of Health & Family Welfare) Government of India; 2013. p. 10-2."},{"key":"key-10.4103\/0974-2727.222168-2","first-page":"51","volume-title":"Blood group typing: From classical strategies to the application of synthetic antibodies generated by molecular imprinting","author":"Mujahid","year":"2015","journal-title":"Sensors"},{"key":"key-10.4103\/0974-2727.222168-3","first-page":"1443","volume-title":"Recent and future trends in blood group typing","author":"Malomgr\u00e9","year":"2009","journal-title":"Anal Bioanal Chem"},{"key":"key-10.4103\/0974-2727.222168-4","first-page":"79","volume-title":"Automated point-of-care testing for ABO agglutination test: Proof of concept and validation","author":"El","year":"2015","journal-title":"Vox Sang"},{"key":"key-10.4103\/0974-2727.222168-5","unstructured":"Dhruva G, Agravat A, Bhankhodia V. Comparison of conventional Tube agglutination method versus Erycard 2.0 for the ABO blood grouping system \u2013 A pilot study. Int J Res Med 2015;4;59-61."},{"key":"key-10.4103\/0974-2727.222168-6","first-page":"474","volume-title":"Determining the accuracy of a rapid point-of-care test for determining Rh(D) phenotype","author":"Herold","year":"2005","journal-title":"Acad Emerg Med"},{"key":"key-10.4103\/0974-2727.222168-7","first-page":"1075","volume-title":"Stability of user-friendly blood typing kits stored under typical military field conditions","author":"Bienek","year":"2009","journal-title":"Mil Med"}],"container-title":["Journal of Laboratory Physicians"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.4103\/JLP.JLP_71_17.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,24]],"date-time":"2023-12-24T08:15:06Z","timestamp":1703405706000},"score":1,"resource":{"primary":{"URL":"https:\/\/jlabphy.org\/evaluation-of-new-indigenous-point-of-care-abo-and-rh-grouping-device\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":7,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2020,2,19]]},"published-print":{"date-parts":[[2018,1]]}},"URL":"https:\/\/doi.org\/10.4103\/jlp.jlp_71_17","relation":{},"ISSN":["0974-2727","0974-7826"],"issn-type":[{"value":"0974-2727","type":"print"},{"value":"0974-7826","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}