{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:41:21Z","timestamp":1786650081768,"version":"build-2736575974"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Organ motion can significantly affect the accurate delivery of radiation doses to the tumor, particularly for sites such as the breast, lung, abdomen, and pelvis. Managing this motion during treatment is crucial. One strategy employed to manage motion induced from respiration is breath-hold (BH), which enhances the geometric precision of dose delivery. Our institute is transitioning to using the ExacTrac Dynamic system to facilitate patient BH using surface-guided cameras. Only 20% of our linacs are equipped with surface guidance capabilities, and due to a high patient stereotactic throughput, the ability to perform in-bunker coaching for BH patients within the bunker is limited. To address this challenge, a time-of-flight camera (ToF) was developed to coach radiotherapy patients undergoing BH procedures, allowing them to gain confidence in the process outside of the bunker and before treatment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The camera underwent testing for absolute and relative accuracy, responsiveness under various environmental conditions, and comparison with the Elekta Active Breathing Coordinator (ABC) to establish correlation and testing on volunteers independently to assess usability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The results showed that the absolute distance measured by the camera was nonlinear due to square light modulation, which was retrospectively corrected. Relative accuracy was tested with a QUASAR motion phantom, with results agreeing to within \u00b1 2 mm. The camera response was found to be unaffected by changes in lighting or temperature, though it overresponded under extreme temperatures. The comparison with the Elekta ABC system yielded comparable results between lung volume and changes in surface distance during BH. All volunteers successfully followed instructions and maintained BH within \u00b1 1 mm tolerance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>This study demonstrates the feasibility of using a cost-effective ToF camera to coach patients before imaging\/treatment, saving valuable LINAC linac and imaging system time.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_101_24","type":"journal-article","created":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T04:00:57Z","timestamp":1734580857000},"page":"502-509","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Cost-effective Breath-hold Coaching Camera System for Patients Undergoing External Beam Radiotherapy"],"prefix":"10.4103","volume":"49","author":[{"given":"Akash","family":"Mehta","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emma","family":"Horgan","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prabhakar","family":"Ramachandran","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Noble","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,12,18]]},"reference":[{"key":"R2-20260424","doi-asserted-by":"crossref","first-page":"785.","DOI":"10.3332\/ecancer.2017.785","article-title":"Recent advances in radiation oncology","volume":"11","author":"Garibaldi","year":"2017","journal-title":"Ecancermedicalscience"},{"key":"R3-20260424","first-page":"555761.","article-title":"Guidelines for using the ABC system on the elekta for respiratory gating treatment","volume":"9","author":"Debra","year":"2018","journal-title":"Canc Therapy Oncol Int J"},{"key":"R5-20260424","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.ejmp.2011.02.002","article-title":"Automatic verification of SSD and generation of respiratory signal with lasers in radiotherapy: A preliminary study","volume":"28","author":"Prabhakar","year":"2012","journal-title":"Phys Med"},{"key":"R10-20260424","doi-asserted-by":"crossref","first-page":"398","DOI":"10.4103\/jmp.jmp_67_22","article-title":"A framework for exactrac dynamic commissioning for stereotactic radiosurgery and stereotactic ablative radiotherapy","volume":"47","author":"Perrett","year":"2022","journal-title":"J Med Phys"},{"key":"R11-20260424","doi-asserted-by":"crossref","first-page":"2595","DOI":"10.1002\/mp.12227","article-title":"Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology","volume":"44","author":"Brandner","year":"2017","journal-title":"Med Phys"},{"key":"R12-20260424","doi-asserted-by":"crossref","first-page":"125.","DOI":"10.1186\/s13014-019-1329-6","article-title":"Evaluation of a 3D surface imaging system for deep inspiration breath-hold patient positioning and intra-fraction monitoring","volume":"14","author":"Hamming","year":"2019","journal-title":"Radiat Oncol"},{"key":"R13-20260424","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/S0360-3016(02)02803-1","article-title":"Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy","volume":"53","author":"Seppenwoolde","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R14-20260424","first-page":"3128","article-title":"Structured-light 3D surface imaging: A tutorial","author":"Geng","year":"2011","journal-title":"Adv Optics Photonics"},{"key":"R15-20260424","author":"Hansard","year":"2013","journal-title":"Time-of-Flight Cameras, London, London Springer"},{"key":"R17-20260424","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.prro.2023.11.013","article-title":"A couch mounted smartphone-based motion monitoring system for radiation therapy","volume":"14","author":"Capaldi","year":"2024","journal-title":"Pract Radiat Oncol"},{"key":"R18-20260424","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1007\/s10877-021-00708-x","article-title":"Accuracy of noncontact surface imaging for tidal volume and respiratory rate measurements in the ICU","volume":"36","author":"L\u2019Her","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R19-20260424","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1111\/crj.13581","article-title":"The use of time-of-flight camera to assess respiratory rates and thoracoabdominal depths in patients with chronic respiratory disease","volume":"17","author":"Van Hove","year":"2023","journal-title":"Clin Respir J"},{"key":"R20-20260424","doi-asserted-by":"crossref","first-page":"10913.","DOI":"10.3390\/app112210913","article-title":"Contactless vital sign monitoring system for heart and respiratory rate measurements with motion compensation using a near-infrared time-of-flight camera","volume":"11","author":"Guo","year":"2021","journal-title":"Appl Sci"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_101_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:01:53Z","timestamp":1786647713000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_101_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_101_24","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"2024-06-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}