{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T09:58:51Z","timestamp":1790330331087,"version":"4.1.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>\n                      CyberKnife\n                      <jats:sup>\u00ae<\/jats:sup>\n                      stereotactic radiosurgery enables frameless, image-guided treatment of multiple brain metastases. Collimator type (Fixed vs. Iris) and planning strategy (Simultaneous vs. Separate) may influence low-dose normal brain exposure, plan quality, and treatment delivery efficiency.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The objective of the study was to compare the dosimetric performance of different collimator types and planning strategies in patients with three or four brain metastases under standardized planning conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Twenty patients were retrospectively replanned using four treatment configurations: Fixed Separate, Fixed Simultaneous, Iris Separate, and Iris Simultaneous. All plans were generated using identical prescription doses and planning objectives. Dosimetric evaluation included normal brain V8, V10, V12 (volumes receiving \u22658 Gy, \u226510 Gy, and \u226512 Gy), mean brain dose (Vmean), Paddick conformity index (PCI), and gradient index (GI). Comparisons were performed using Friedman and Wilcoxon signed-rank tests. Estimated treatment time was recorded for all plans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Significant differences were observed for V8 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.039), Vmean (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.019), and PCI (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), whereas V10 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.180), V12 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.103), and GI (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.420) showed no significant differences among the planning approaches. Median dosimetric values tended to favor Iris Simultaneous planning for reducing low-dose normal brain exposure. The significant PCI difference was primarily attributable to lower conformity in the Iris Separate plans. Total planning target volume demonstrated a near-significant positive association with V12 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.057). Iris-based plans were associated with shorter estimated treatment times.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Under standardized planning conditions, Iris Simultaneous planning demonstrated favorable trends in reducing low-dose normal brain exposure while improving treatment delivery efficiency. Although conformity differed significantly among planning approaches, mainly because of lower PCI values in the Iris Separate plans, dose gradient characteristics remained comparable. These findings suggest that planning strategy may influence conformity more than dose fall-off in CyberKnife treatment of multiple brain metastases. Nevertheless, given the limited sample size, these results should be interpreted cautiously and validated in larger prospective studies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_11_26","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T13:02:15Z","timestamp":1790168535000},"page":"628-636","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Dosimetric Impact of Simultaneous and Separate Planning with Fixed\/Iris Collimators on Brain Doses in Multiple Brain Metastases"],"prefix":"10.4103","volume":"51","author":[{"given":"Hatice","family":"Tataroglu","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, Samsun Training and Research Hospital, Samsun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ela Delikg\u00f6z","family":"Soykut","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Samsun Training and Research Hospital, Samsun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustafa","family":"\u00d6zer","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Samsun Training and Research Hospital, Samsun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seher","family":"Pirzirenli","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Ondokuz Mayis University, Samsun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"key":"R1-20260925","doi-asserted-by":"crossref","first-page":"2698","DOI":"10.1002\/cncr.10541","article-title":"Incidence of brain metastases in a cohort of patients with carcinoma of the breast, colon, kidney, and lung and melanoma","volume":"94","author":"Schouten","year":"2002","journal-title":"Cancer"},{"key":"R2-20260925","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1001\/jama.2016.9839","article-title":"Effect of radiosurgery alone versus radiosurgery with whole brain radiation therapy on cognitive function in patients with 1 to 3 brain metastases: A randomized clinical trial","volume":"316","author":"Brown","year":"2016","journal-title":"JAMA"},{"key":"R3-20260925","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.ijrobp.2014.10.024","article-title":"Phase 3 trials of stereotactic radiosurgery with or without whole-brain radiation therapy for 1 to 4 brain metastases: Individual patient data meta-analysis","volume":"91","author":"Sahgal","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R4-20260925","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.prro.2022.02.003","article-title":"Radiation therapy for brain metastases: An ASTRO clinical practice guideline","volume":"12","author":"Gondi","year":"2022","journal-title":"Pract Radiat Oncol"},{"key":"R5-20260925","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.ijrobp.2020.08.013","article-title":"Single- and Multifraction Stereotactic Radiosurgery Dose\/Volume Tolerances of the Brain","volume":"110","author":"Milano","year":"2021","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R6-20260925","first-page":"1299","article-title":"Image-guided robotic radiosurgery","volume":"44","author":"Adler","year":"1999","journal-title":"Neurosurgery"},{"key":"R7-20260925","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1177\/153303461000900502","article-title":"The CyberKnife robotic radiosurgery system in 2010","volume":"9","author":"Kilby","year":"2010","journal-title":"Technol Cancer Res Treat"},{"key":"R9-20260925","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1200\/JCO.21.02314","article-title":"Treatment for brain metastases: ASCO-SNO-ASTRO guideline","volume":"40","author":"Vogelbaum","year":"2022","journal-title":"J Clin Oncol"},{"key":"R10-20260925","doi-asserted-by":"crossref","first-page":"797250","DOI":"10.3389\/fonc.2022.797250","article-title":"Comparison of Two Cyberknife Planning Approaches for Multiple Brain Metastases","volume":"12","author":"Ji","year":"2022","journal-title":"Front Oncol"},{"key":"R11-20260925","doi-asserted-by":"crossref","first-page":"120","DOI":"10.4103\/jmp.jmp_82_22","article-title":"Multiple brain metastases radiosurgery with CyberKnife device: Dosimetric comparison between fixed\/iris and multileaf collimator plans","volume":"48","author":"Ianiro","year":"2023","journal-title":"J Med Phys"},{"key":"R12-20260925","doi-asserted-by":"crossref","first-page":"780","DOI":"10.3390\/cancers15030780","article-title":"Dosimetric Impact of Lesion Number, Size, and Volume on Mean Brain Dose with Stereotactic Radiosurgery for Multiple Brain Metastases","volume":"15","author":"La Rosa","year":"2023","journal-title":"Cancers (Basel)"},{"key":"R13-20260925","doi-asserted-by":"crossref","first-page":"e174","DOI":"10.1016\/j.wneu.2019.11.089","article-title":"Stereotactic radiosurgery to more than 10 brain metastases: Evidence to support the role of radiosurgery for ideal hippocampal sparing in the treatment of multiple brain metastases","volume":"135","author":"Susko","year":"2020","journal-title":"World Neurosurg"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_11_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T09:00:46Z","timestamp":1790326846000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_11_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_11_26","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2026-01-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}