{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:35:28Z","timestamp":1786649728365,"version":"build-2736575974"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:p>Gafchromic LD-V1 (LD-V1) is a highly sensitive radiochromic film used as a radiation measurement technique that can be applied to the surface of an object because of its flexibility. However, if radiation is incident on the film from an angle other than perpendicular, the film\u2019s sensitivity may change depending on the angle of incidence. In this study, we investigated the directional dependence of LD-V1 on the surface of an acrylic phantom. The relative sensitivity at the angle of perpendicular incidence of X-rays on the film was 54.5%, while the relative sensitivity at other angles exceeded 90%. The LD-V1 can perform measurements at angles other than perpendicular X-ray incidence.<\/jats:p>","DOI":"10.4103\/jmp.jmp_154_24","type":"journal-article","created":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T04:01:19Z","timestamp":1751515279000},"page":"419-425","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Directional Dependence of Gafchromic LD-V1"],"prefix":"10.4103","volume":"50","author":[{"given":"Shinnosuke","family":"Nishihara","sequence":"first","affiliation":[{"name":"Health Science and Technology, Graduate School of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuhiro","family":"Gotanda","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Sciences and Technology, Kawasaki University of Medical Welfare, Okayama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoyuki","family":"Hasuo","sequence":"additional","affiliation":[{"name":"Health Science and Technology, Graduate School of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama, Japan"},{"name":"Osaka Center for Cancer and Cardiovascular Disease Prevention, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinya","family":"Imai","sequence":"additional","affiliation":[{"name":"Department of Radiological Science, Faculty of Health Science, Morinomiya University of Medical Sciences, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuyuki","family":"Kawaji","sequence":"additional","affiliation":[{"name":"Department of Radiological Science, Faculty of Health Science, Junshin Gakuen University, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidetoshi","family":"Yatake","sequence":"additional","affiliation":[{"name":"Department of Breast Cancer Center, Kaizuka City Hospital, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Akagawa","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Tokushima Red Cross Hospital, Tokushima, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rumi","family":"Gotanda","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Sciences and Technology, Kawasaki University of Medical Welfare, Okayama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyoshi","family":"Tanki","sequence":"additional","affiliation":[{"name":"Brain Activity Imaging Center, ATR-Promotions Inc., Kyoto, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshizo","family":"Katsuda","sequence":"additional","affiliation":[{"name":"Medical Radiation Technology, Shizuoka College of Medical Care Science, Hamamatsu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,3]]},"reference":[{"key":"R1-20250703","doi-asserted-by":"crossref","first-page":"5986","DOI":"10.1002\/mp.14497","article-title":"Report of AAPM task group 235 radiochromic film dosimetry: An update to TG-55","volume":"47","author":"Niroomand-Rad","year":"2020","journal-title":"Med Phys"},{"key":"R2-20250703","doi-asserted-by":"crossref","first-page":"2391","DOI":"10.1093\/rpd\/ncad237","article-title":"Comparison of sensitivity characteristics between GAFCHROMIC LD-V1 and GAFCHROMIC XR-QA2 in mammographic dosimetry","volume":"199","author":"Gotanda","year":"2023","journal-title":"Radiat Prot Dosimetry"},{"key":"R3-20250703","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1118\/1.3271584","article-title":"Computed tomography dose measurements with radiochromic films and a flatbed scanner","volume":"37","author":"Rampado","year":"2010","journal-title":"Med Phys"},{"key":"R4-20250703","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1093\/rpd\/ncab153","article-title":"Three-dimensional dosimetry of mammography using a block cube breast phantom and radiochromic film","volume":"196","author":"Gotanda","year":"2021","journal-title":"Radiat Prot Dosimetry"},{"key":"R5-20250703","first-page":"61","article-title":"Use of ultraviolet ray pre-irradiation to improve the accuracy of low-dose measurements of the Ct using a gafchromic rtqa2 film","volume":"195","author":"Katsuda","year":"2021","journal-title":"Radiat Prot Dosimetry"},{"key":"R6-20250703","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1093\/rpd\/ncab033","article-title":"The concept of X-ray CT dose evaluation method using radiochromic film and film-folding phantom","volume":"193","author":"Tanki","year":"2021","journal-title":"Radiat Prot Dosimetry"},{"key":"R7-20250703","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s13246-011-0068-2","article-title":"Evaluation of effective energy using radiochromic film and a step-shaped aluminum filter","volume":"34","author":"Gotanda","year":"2011","journal-title":"Australas Phys Eng Sci Med"},{"key":"R8-20250703","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1007\/BF03178604","article-title":"Dose distribution in pediatric CT head examination using a new phantom with radiochromic film","volume":"31","author":"Gotanda","year":"2008","journal-title":"Australas Phys Eng Sci Med"},{"key":"R9-20250703","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1007\/BF03178426","article-title":"Computed tomography phantom for radiochromic film dosimetry","volume":"30","author":"Gotanda","year":"2007","journal-title":"Australas Phys Eng Sci Med"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_154_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:57:42Z","timestamp":1786647462000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_154_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":9,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_154_24","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-09-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}