{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:46:13Z","timestamp":1787071573141,"version":"build-2736575974"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Cone-beam computed tomography (CBCT) is widely used in imaging-guided radiotherapy for precise treatment planning and patient positioning. However, the ionizing radiation used in CBCT poses inherent risks to patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>This study evaluated the feasibility of radiophotoluminescent. glass dosimeter system GD-352M for measuring radiation dose in kilovoltage CBCT (kV-CBCT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The GD-352M demonstrated good uniformity, linearity, accuracy, reproducibility, and low-energy dependence. Moreover, the FDG-1000 automatic reader system exhibited consistent readout values that were not influenced by the magazine\u2019s position. The GD-352M demonstrated good uniformity, linearity, and accuracy, with a combined measurement uncertainty of 4.56%, confirming its suitability for kV-CBCT dosimetry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>These findings indicate the suitability of the GD-352M dosimeter for measuring dose range in kV-CBCT and improve patient safety in kV-CBCT dosimetry.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_184_24","type":"journal-article","created":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T12:00:11Z","timestamp":1759147211000},"page":"560-564","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility of Radiophotoluminescent Glass Dosimeter for Measuring Radiation Dose in Kilovoltage Cone-beam Computed Tomography"],"prefix":"10.4103","volume":"50","author":[{"given":"Kantida","family":"Jittrakool","sequence":"first","affiliation":[{"name":"Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sakda","family":"Kingkaew","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nichakan","family":"Chatchumnan","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Puntiwa","family":"Oonsiri","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sornjarod","family":"Oonsiri","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mananchaya","family":"Vimolnoch","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,9,29]]},"reference":[{"key":"R2-20260420","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.zemedi.2023.03.002","article-title":"Imaging doses for different CBCT protocols on the Halcyon 3.0 linear accelerator \u2013 TLD measurements in an anthropomorphic phantom","volume":"34","author":"Altergot","year":"2024","journal-title":"Z Med Phys"},{"key":"R3-20260420","doi-asserted-by":"crossref","first-page":"255","DOI":"10.5516\/NET.08.2012.080","article-title":"Effective dose measurement for cone beam computed tomography using glass dosimeter","volume":"46","author":"Moon","year":"2014","journal-title":"Nucl Eng Technol"},{"key":"R4-20260420","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1093\/rpd\/nci510","article-title":"Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters","volume":"119","author":"Hsu","year":"2006","journal-title":"Radiat Prot Dosimetry"},{"key":"R5-20260420","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.radmeas.2008.10.010","article-title":"A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter","volume":"44","author":"Rah","year":"2009","journal-title":"Radiat Meas"},{"key":"R6-20260420","first-page":"837","article-title":"Radiation exposure in cone beam CT measured using a MOSFET and RPLGD dosimeter and Monte Carlo simulation in phantom","volume":"31","author":"Kweon","year":"2023","journal-title":"J Xray Sci Technol"},{"key":"R7-20260420","doi-asserted-by":"crossref","first-page":"1980","DOI":"10.1118\/1.1758351","article-title":"Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and cyber-knife","volume":"31","author":"Arakia","year":"2004","journal-title":"Med Phys"},{"key":"R8-20260420","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.radonc.2007.10.024","article-title":"Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams","volume":"86","author":"Mizuno","year":"2008","journal-title":"Radiother Oncol"},{"key":"R9-20260420","doi-asserted-by":"crossref","first-page":"1980","DOI":"10.1016\/j.apradiso.2008.06.041","article-title":"Application of a glass rod detector for the output factor measurement in the CyberKnife","volume":"66","author":"Rah","year":"2008","journal-title":"Appl Radiat Isot"},{"key":"R10-20260420","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.apradiso.2008.09.018","article-title":"Feasibility study of radiophotoluminescent glass rod dosimeter postal dose intercomparison for high energy photon beam","volume":"67","author":"Rah","year":"2009","journal-title":"Appl Radiat Isot"},{"key":"R15-20260420","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/S0969-8043(99)00124-4","article-title":"Dosimetric characterisation of a new production of MgB4O7:Dy,Na thermoluminescent material","volume":"52","author":"Furetta","year":"2000","journal-title":"Appl Radiat Isot"},{"key":"R16-20260420","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.net.2021.08.016","article-title":"Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity","volume":"54","author":"Kim","year":"2022","journal-title":"Nucl Eng Technol"},{"key":"R17-20260420","first-page":"65","article-title":"Investigation of the dosimetric characteristics of radiophotoluminescent glass dosimeter for high-energy photon beams","volume":"12","author":"Oonsiri","year":"2019","journal-title":"J Radiat Res Appl Sci"},{"key":"R18-20260420","article-title":"Dosimetry with Radiophotoluminescent Glass Dosimeters for Dosimetry Audit in MV X-Ray Radiotherapy","year":"2019","journal-title":"SS\/ISO 22127"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_184_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:48:36Z","timestamp":1787068116000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_184_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_184_24","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"2024-10-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}