{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:35:41Z","timestamp":1786649741456,"version":"build-2736575974"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study aims to evaluate radiation doses to the skin, pelvis, and skull during routine radiographic imaging procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Entrance skin dose (ESD) was assessed using both direct and indirect methods. Direct measurements were conducted with thermoluminescent dosimeter (TLD)-100H TLDs placed on an Alderson RANDO female anthropomorphic phantom. Indirect measurements were obtained using the calibrated output of the X-ray tube. Organ dose estimations were also derived through thermoluminescence dosimetry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Direct measurements yielded ESD values of 0.27 mGy for chest, 2.36 mGy for pelvis, and 2.54 mGy for skull radiography. Corresponding values from the indirect method were 0.26 mGy, 2.29 mGy, and 2.43 mGy, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The radiation dose levels obtained are consistent with the national diagnostic reference levels in Iran. These findings support the ongoing optimization of radiographic practices in alignment with the as low as reasonably achievable principle.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_39_25","type":"journal-article","created":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T04:01:38Z","timestamp":1751515298000},"page":"385-390","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Radiation Dose Assessment in Diagnostic Imaging Using Thermoluminescent Dosimeter-100H Dosimeters and a RANDO Phantom: Insights from Chest, Pelvic, and Skull Examinations"],"prefix":"10.4103","volume":"50","author":[{"given":"Sedigheh","family":"Sina","sequence":"first","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"},{"name":"Radiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shima","family":"Alizadeh","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sadegh","family":"Abbasipour","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mozhgan","family":"Dalir","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohaddeseh","family":"Heydarinia","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatemeh","family":"Norouzalizadeh","sequence":"additional","affiliation":[{"name":"Radiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mobarakeh","family":"Nasiri","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad Hossein","family":"Sadeghi","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazem Sadeghi Ebrahim","family":"Mohammadi","sequence":"additional","affiliation":[{"name":"Radiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elnaz","family":"Saeedian","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoo","family":"Shakerian","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahboobeh","family":"Sheiki","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran"},{"name":"Department of Nuclear Medicine, Abu Ali Sina Hospital, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,3]]},"reference":[{"key":"R1-20250703","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1177\/01466453231210646","article-title":"Optimisation of radiological protection in digital radiology techniques for medical imaging","volume":"52","year":"2023","journal-title":"Ann ICRP"},{"key":"R2-20250703","doi-asserted-by":"crossref","first-page":"11","DOI":"10.34172\/ajchor.2","article-title":"Estimation of entrance surface dose and dose area product in most frequently used radiography examinations in Hamadan","volume":"1","author":"Heidari","year":"2023","journal-title":"Avicenna J Care Health Oper Room"},{"key":"R3-20250703","doi-asserted-by":"crossref","first-page":"e0172256","DOI":"10.1371\/journal.pone.0172256","article-title":"Improving early diagnosis of pulmonary infections in patients with febrile neutropenia using low-dose chest computed tomography","volume":"12","author":"Gerritsen","year":"2017","journal-title":"PLoS One"},{"key":"R4-20250703","doi-asserted-by":"crossref","first-page":"212","DOI":"10.4103\/jmp.jmp_23_22","article-title":"Radiation dose management of pregnant patients, pregnant staff and paediatric patients diagnostic and interventional radiology","volume":"47","author":"Srivastava","year":"2022","journal-title":"J Med Phys"},{"key":"R6-20250703","first-page":"269","article-title":"Variation of pediatric doses undergoing digital and computed radiography examination in Addis Ababa, Ethiopia","volume":"30","author":"Teferi","year":"2020","journal-title":"Ethiop J Health Sci"},{"key":"R7-20250703","first-page":"118","article-title":"Evaluation of the entrance skin dose in animals undergoing diagnostic radiology using LiF, Mg, Ti thermoluminescence dosimetry (TLD-100)","volume":"13","author":"Sina","year":"2016","journal-title":"Iran J Med Phys"},{"key":"R8-20250703","first-page":"161","article-title":"Validation and comparison the dose results of simulated head phantom by GATE Monte Carlo code with Thermoluminescent dosimeter responses in PET imaging","volume":"11","author":"Sina","year":"2023","journal-title":"J Radiat Saf Meas"},{"key":"R9-20250703","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1093\/rpd\/ncaa083","article-title":"Measurement of operational dosimetry quantities for nuclear medicine staff","volume":"190","author":"Dehghan","year":"2020","journal-title":"Radiat Prot Dosimetry"},{"key":"R10-20250703","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1093\/rpd\/ncae008","article-title":"Measurement of Hp(10), Hp(3) and Hp(0.07) to medical staff in endoscopic retrograde cholangiopancreatography, using thermoluminescence dosimetry","volume":"200","author":"ZarifSanayei","year":"2024","journal-title":"Radiat Prot Dosimetry"},{"key":"R11-20250703","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1590\/0100-3984.2013.1800","article-title":"Dosimetry of patients submitted to cerebral PET\/CT for the diagnosis of mild cognitive impairment","volume":"47","author":"Santana","year":"2014","journal-title":"Radiol Bras"},{"key":"R12-20250703","doi-asserted-by":"crossref","first-page":"3404","DOI":"10.1118\/1.4718710","article-title":"Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols","volume":"39","author":"Zhang","year":"2012","journal-title":"Med Phys"},{"key":"R13-20250703","doi-asserted-by":"crossref","first-page":"3205","DOI":"10.3390\/cancers14133205","article-title":"Skin surface dose for whole breast radiotherapy using personalized breast holder: Comparison with various radiotherapy techniques and clinical experiences","volume":"14","author":"Chen","year":"2022","journal-title":"Cancers (Basel)"},{"key":"R15-20250703","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1148\/radiol.2016160384","article-title":"Effect of localizer radiography projection on organ dose at chest CT with automatic tube current modulation","volume":"282","author":"Saltybaeva","year":"2017","journal-title":"Radiology"},{"key":"R16-20250703","doi-asserted-by":"crossref","first-page":"23901","DOI":"10.1118\/1.4859315","article-title":"Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus","volume":"41","author":"Zhang","year":"2014","journal-title":"Med Phys"},{"key":"R17-20250703","first-page":"2","article-title":"The 2007 recommendations of the international commission on radiological protection. ICRP publication 103","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"R18-20250703","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.21037\/jtd.2020.02.31","article-title":"Optical imaging versus CT and plain radiography to quantify pectus severity: A systematic review and meta-analysis","volume":"12","author":"Daemen","year":"2020","journal-title":"J Thorac Dis"},{"key":"R19-20250703","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1088\/1361-6498\/aba083","article-title":"Proposed diagnostic reference levels for general radiography and mammography in Japan","volume":"40","author":"Asada","year":"2020","journal-title":"J Radiol Prot"},{"key":"R20-20250703","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1093\/rpd\/ncw300","article-title":"Developing an optimum protocol for thermoluminescence dosimetry with GR-200 chips using Taguchi method","volume":"175","author":"Sadeghi","year":"2017","journal-title":"Radiat Prot Dosimetry"},{"key":"R21-20250703","doi-asserted-by":"crossref","first-page":"569","DOI":"10.31661\/jbpe.v0i0.878","article-title":"Measurement of entrance skin dose and dose received by different organs in panoramic dental imaging","volume":"10","author":"Ahmadi","year":"2020","journal-title":"J Biomed Phys Eng"},{"key":"R23-20250703","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1088\/0031-9155\/48\/12\/310","article-title":"An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms","volume":"48","author":"Omrane","year":"2003","journal-title":"Phys Med Biol"},{"key":"R24-20250703","first-page":"227","article-title":"National diagnostic reference levels (DRLs) for general and interventional radiography, mammography, and CT scan based on the latest surveys in Iran","volume":"41","author":"Sina","year":"2024","journal-title":"Radioprotection"},{"key":"R26-20250703","first-page":"897","article-title":"A study on the diagnostic reference level of skull radiography in digital radiography","volume":"16","author":"Hong","year":"2022","journal-title":"J Korean Soc Radiol"},{"key":"R27-20250703","doi-asserted-by":"crossref","first-page":"2898","DOI":"10.1118\/1.3121505","article-title":"An exposure indicator for digital radiography: AAPM task group 116 (executive summary)","volume":"36","author":"Shepard","year":"2009","journal-title":"Med Phys"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_39_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:57:52Z","timestamp":1786647472000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_39_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_39_25","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2025-02-12","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}