{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:32:04Z","timestamp":1787776324325,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>\n                      The aim of this study is to estimate delivered radiation doses inside planning tumor volume (PTV) using the\n                      <jats:italic toggle=\"yes\">in vivo<\/jats:italic>\n                      (mid-plane dose) measurement and transit measurement methods in gynecological malignancy patients undergoing three-dimensional conformal radiotherapy (3DCRT) using calibrated ionization chambers.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Six patients with histopathologically proven carcinoma of the cervix or endometrium were planned with four-field 3DCRT to the pelvic site. Isocenter was at the geometric mid-plane of PTV with a dose prescription of 50 Gy in 25 fractions. Clinical mid-plane dose (D\n                      <jats:italic toggle=\"yes\">iso,\n                                    Transit)<\/jats:italic>\n                      estimates were done in one method (transit) using the FC-65 positioned at electronic portal imaging device level. In another method, a repeat computerized tomography scan was performed (at the 11\n                      <jats:sup>th<\/jats:sup>\n                      fraction) using CC-13 having a protective cap in the vaginal cavity for\n                      <jats:italic toggle=\"yes\">in vivo<\/jats:italic>\n                      measurements (D\n                      <jats:italic toggle=\"yes\">in vivo<\/jats:italic>\n                      ). Simultaneous measurements were performed with the two chambers from the 11\n                      <jats:sup>th<\/jats:sup>\n                      fraction onward at least 3\u20134 times during the remaining course of treatment.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The agreement of mean doses from these two described methods and treatment planning system reference doses was in the range of \u22124.4 \u00b1 1.1% (minimum) to \u22120.3 \u00b1 2.0% (maximum) and \u22124.0 \u00b1 1.7% (minimum) to 1.9 \u00b1 2.4% for D\n                      <jats:italic toggle=\"yes\">in\n                                    vivo and<\/jats:italic>\n                      D\n                      <jats:italic toggle=\"yes\">iso,\n                                    Transit<\/jats:italic>\n                      , respectively, which are an acceptable range of daily radiation dose delivery.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The fundamental importance of this study lies in simultaneous validation of delivered dose in real time with two methods. A study in this small number of patients has given the confidence to apply transit measurements for quality assurance on a routine basis as an accepted clinical dosimetry for the selected patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_3_20","type":"journal-article","created":{"date-parts":[[2020,7,20]],"date-time":"2020-07-20T07:38:15Z","timestamp":1595230695000},"page":"123-129","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Simultaneous Measurement of In vivo and Transit Mid-Plane Doses with Ionization Chambers in Gynecological Malignancy Patients Undergoing Three-Dimensional Conformal Radiotherapy"],"prefix":"10.4103","volume":"45","author":[{"given":"Putha Suman","family":"Kumar","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Challapalli","family":"Srinivas","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B. M.","family":"Vadhiraja","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Manipal Hospitals, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sourjya","family":"Banerjee","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Shreyas","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"PU","family":"Prakash Saxena","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramamoorthy","family":"Ravichandran","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dilson","family":"Lobo","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Kasturba Medical College (A constituent institution of Manipal Academy of Higher Education, Manipal), Mangalore, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,7,20]]},"reference":[{"key":"R1-20260306","first-page":"1","article-title":"Development of procedures for in vivo dosimetry in radiotherapy","volume":"8","author":"Human","year":"2013","journal-title":"IAEA Human Health Reports"},{"key":"R2-20260306","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.radonc.2007.03.003","article-title":"Routine individualised patient dosimetry using electronic portal imaging devices","volume":"83","author":"Nijsten","year":"2007","journal-title":"Radiother Oncol"},{"key":"R3-20260306","doi-asserted-by":"crossref","first-page":"224","DOI":"10.4103\/0971-6203.195186","article-title":"On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator","volume":"41","author":"Putha","year":"2016","journal-title":"J Med Phys"},{"key":"R4-20260306","doi-asserted-by":"crossref","first-page":"47","DOI":"10.4103\/0971-6203.49950","article-title":"In vivo dosimetric study of carcinoma of uterine cervix with FBX solution in external beam therapy","volume":"24","author":"Srinivas","year":"1999","journal-title":"J Med Phys"},{"key":"R5-20260306","doi-asserted-by":"crossref","first-page":"2638","DOI":"10.1118\/1.3397807","article-title":"Catching errors with in vivo EPID dosimetry","volume":"37","author":"Mans","year":"2010","journal-title":"Med Phys"},{"key":"R6-20260306","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1016\/j.ijrobp.2003.12.008","article-title":"Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine","volume":"58","author":"Galvin","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R7-20260306","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1093\/rpd\/ncn231","article-title":"State of the art of in vivo dosimetry","volume":"131","author":"Mijnheer","year":"2008","journal-title":"Radiat Prot Dosimetry"},{"key":"R8-20260306","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1118\/1.3514120","article-title":"Dosimetry tools and techniques for IMRT","volume":"38","author":"Low","year":"2011","journal-title":"Med Phys"},{"key":"R9-20260306","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/S0360-3016(03)00197-4","article-title":"Patient-specific point dose measurement for IMRT monitor unit verification","volume":"56","author":"Dong","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R10-20260306","first-page":"177","article-title":"In vivo dosimetry: Confirmation of dose delivery through transit dose measurements in carcinoma of uterine cervix patients undergoing teletherapy","volume":"29","author":"Srinivas","year":"2004","journal-title":"J Med Phys"},{"key":"R11-20260306","article-title":"Guidelines for the Verification of IMRT, ESTRO Booklet 9, Brussels: ESTRO","author":"Mijnheer","year":"2008"},{"key":"R12-20260306","article-title":"\u201cIntensity modulated radiation therapy,\u201d The Modern Technology of Radiation Oncology: A Compendium for Medical Physicists and Radiation Oncologists","author":"Xia","year":"2005"},{"key":"R13-20260306","doi-asserted-by":"crossref","first-page":"518","DOI":"10.2214\/ajr.105.3.518","article-title":"Dosimetric considerations in cobalt 60 rotational therapy for esophageal lesions. A comparison of transit and intraluminal dose measurement","volume":"105","author":"Goldenberg","year":"1969","journal-title":"Am J Roentgenol Radium Ther Nucl Med"},{"key":"R14-20260306","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.ijrobp.2006.09.008","article-title":"Image-guided in vivo dosimetry for quality assurance of IMRT treatment for prostate cancer","volume":"67","author":"Wertz","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R15-20260306","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.radonc.2007.10.014","article-title":"Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs kV portal images vs cone-beam CT","volume":"85","author":"Walter","year":"2007","journal-title":"Radiother Oncol"},{"key":"R16-20260306","doi-asserted-by":"crossref","first-page":"247","DOI":"10.4103\/0971-6203.144492","article-title":"Dose verification in carcinoma of uterine cervix patients undergoing 3D conformal radiotherapy with Farmer type ion chamber","volume":"39","author":"Srinivas","year":"2014","journal-title":"J Med Phys"},{"key":"R17-20260306","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S1120-1797(05)80003-1","article-title":"In-vivo portal dosimetry by an ionization chamber","volume":"21","author":"Piermattei","year":"2005","journal-title":"Phys Med"},{"key":"R18-20260306","doi-asserted-by":"crossref","first-page":"4414","DOI":"10.1118\/1.2360014","article-title":"In vivo dosimetry by an aSi-based EPID","volume":"33","author":"Piermattei","year":"2006","journal-title":"Med Phys"},{"key":"R19-20260306","doi-asserted-by":"crossref","first-page":"5101","DOI":"10.1088\/0031-9155\/52\/16\/026","article-title":"Application of a practical method for the isocenter point in vivo dosimetry by a transit signal","volume":"52","author":"Piermattei","year":"2007","journal-title":"Phys Med Biol"},{"key":"R20-20260306","doi-asserted-by":"crossref","first-page":"300","DOI":"10.4103\/jcrt.JCRT_278_17","article-title":"In vivo dose estimations through transit signal measured with thimble chamber positioned along the central axis at electronic portal imaging device level in medical linear accelerator in carcinoma of the middle-third esophagus patients undergoing three-dimensional conformal radiotherapy","volume":"14","author":"Kumar","year":"2018","journal-title":"J Cancer Res Ther"},{"key":"R22-20260306","first-page":"37","article-title":"Clinical application of in vivo dosimetry system in radiotherapy of pelvis","volume":"27","author":"Kim","year":"2002","journal-title":"J Radiat Prot Res"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.JMP_3_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:07:08Z","timestamp":1787774828000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.JMP_3_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_3_20","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4]]},"assertion":[{"value":"2020-01-14","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}