{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T12:57:11Z","timestamp":1787921831578,"version":"build-2784847793"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The purpose of this study is to present the multivariate analysis of the size-specific dose estimate (SSDE) and E in pediatric computed tomography (CT) imaging. Pediatric patients scheduled for CT scans of the head, thorax, and abdomen from July 2022 to February 2024 were included in the prospective study. The water-equivalent diameter (\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    ), SSDE, and E were computed for each examination using the dose report of CT console display computed tomography dose index (\n                    <jats:italic toggle=\"yes\">CTD1<\/jats:italic>\n                    <jats:sub>vol<\/jats:sub>\n                    ) and dose length product (DLP). The correlation between SSDE and E on\n                    <jats:italic toggle=\"yes\">CTD1<\/jats:italic>\n                    <jats:sub>vol<\/jats:sub>\n                    ,\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    ,\n                    <jats:italic toggle=\"yes\">Area<\/jats:italic>\n                    <jats:sub>ROI<\/jats:sub>\n                    , body mass index,\n                    <jats:italic toggle=\"yes\">Size\u2044(LAT+AP)<\/jats:italic>\n                    , age,\n                    <jats:italic toggle=\"yes\">fsize<\/jats:italic>\n                    , and\n                    <jats:italic toggle=\"yes\">HU<\/jats:italic>\n                    <jats:sub>mean<\/jats:sub>\n                    in the region of interest was examined using the multivariate statistical analysis with 95% level of significance (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; 0.05). The relationship between\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    and\n                    <jats:italic toggle=\"yes\">Size\u2044(LAT+AP)<\/jats:italic>\n                    ,\n                    <jats:italic toggle=\"yes\">Size\u2044(LAT+AP)<\/jats:italic>\n                    , and\n                    <jats:italic toggle=\"yes\">fsize<\/jats:italic>\n                    versus age was investigated using linear regression analysis. The mean values of SSDE for noncontrast head CT and contrast-enhanced CT were found 71.36\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    and 97.38\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    , respectively. While as, the mean SSDE for contrast-enhanced thorax CT was observed to be 5.82\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    , which is less than the mean SSDE of 6.40\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    for noncontrast thorax CT imaging. The range of the SSDE for contrast-enhanced abdomen CT is 2.05\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    to 22.13\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    with a mean SSDE of around 5.71\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    and for noncontrast abdomen imaging, mean value of SSDE was 5.58\n                    <jats:italic toggle=\"yes\">mGy<\/jats:italic>\n                    . The mean value of \u201cE\u201d for noncontrast thorax CT imaging was observed to be 2.7\n                    <jats:italic toggle=\"yes\">mSv<\/jats:italic>\n                    with minimum and maximum 1.17\n                    <jats:italic toggle=\"yes\">mSv<\/jats:italic>\n                    to 10.10\n                    <jats:italic toggle=\"yes\">mSv<\/jats:italic>\n                    respectively, which less than the mean effective dose is of 3.64\n                    <jats:italic toggle=\"yes\">mSv<\/jats:italic>\n                    observed for contrast enhanced thorax CT imaging. The multivariate analysis suggests that SSDE is significantly correlated with\n                    <jats:italic toggle=\"yes\">CTD1<\/jats:italic>\n                    <jats:sub>vol<\/jats:sub>\n                    ,\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    , and E is found significantly dependent on DLP for both contrast enhanced and noncontrast imaging with\n                    <jats:italic toggle=\"yes\">p<\/jats:italic>\n                    &lt; 0.05. A strong positive correlation was found between\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    and\n                    <jats:italic toggle=\"yes\">Size\u2044(LAT+AP)<\/jats:italic>\n                    , form linear regression analysis. The SSDE is crucial for radiologists evaluating pediatric CT scans and is now an international standard expected to be widely adopted. The strong positive correlation between\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    versus\n                    <jats:italic toggle=\"yes\">Size\u2044(LAT+AP)<\/jats:italic>\n                    , indicates that\n                    <jats:italic toggle=\"yes\">Size\u2044(LAT+AP)<\/jats:italic>\n                    ,can be used as surrogate in estimate SSDE when\n                    <jats:italic toggle=\"yes\">D<\/jats:italic>\n                    <jats:sub>w<\/jats:sub>\n                    calculation is not feasible for pediatric CT imaging.\n                  <\/jats:p>","DOI":"10.4103\/jmp.jmp_55_24","type":"journal-article","created":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T18:01:28Z","timestamp":1742839288000},"page":"173-183","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Size-Specific Dose Estimate and Effective Dose for Pediatric Computed Tomography"],"prefix":"10.4103","volume":"50","author":[{"given":"Rukhsar","family":"Khan","sequence":"first","affiliation":[{"name":"Department of Radiodiagnosis, Faculty of Medicine, J. N Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mudasir Ashraf","family":"Shah","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Faculty of Medicine, J. N Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shagufta","family":"Wahab","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Faculty of Medicine, J. N Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rizwan Ahmad","family":"Khan","sequence":"additional","affiliation":[{"name":"Paediatric Surgery, Faculty of Medicine, J. N Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,3,24]]},"reference":[{"key":"R1-20250324","doi-asserted-by":"crossref","first-page":"E575","DOI":"10.1503\/cmaj.221303","article-title":"Risks of leukemia, intracranial tumours and lymphomas in childhood and early adulthood after pediatric radiation exposure from computed tomography","volume":"195","author":"Wang","year":"2023","journal-title":"CMAJ"},{"key":"R2-20250324","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1007\/s00247-011-2110-7","article-title":"CT scans in young people in Northern England:Trends and patterns 1993-2002","volume":"41","author":"Pearce","year":"2011","journal-title":"Pediatr Radiol"},{"key":"R3-20250324","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1097\/JCMA.0000000000000199","article-title":"Trends in computed tomography scan uses in Taiwan from 2000 to 2013","volume":"82","author":"Hsueh","year":"2019","journal-title":"J Chin Med Assoc"},{"key":"R4-20250324","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1001\/jama.2019.11456","article-title":"Trends in use of medical imaging in US health care systems and in Ontario, Canada, 2000-2016","volume":"322","author":"Smith-Bindman","year":"2019","journal-title":"JAMA"},{"key":"R5-20250324","doi-asserted-by":"crossref","first-page":"4973","DOI":"10.1073\/pnas.1031538100","article-title":"Low-dose radiation:Thresholds, bystander effects, and adaptive responses","volume":"100","author":"Bonner","year":"2003","journal-title":"Proc Natl Acad Sci U S A"},{"key":"R6-20250324","doi-asserted-by":"crossref","first-page":"100235","DOI":"10.1016\/j.lansea.2023.100235","article-title":"An assessment of childhood cancer care services in India \u2013Gaps, challenges and the way forward","volume":"16","author":"Nath","year":"2023","journal-title":"Lancet Reg Health Southeast Asia"},{"key":"R7-20250324","first-page":"100833","article-title":"Review of paediatric sedation and anaesthesia for radiological diagnostic and therapeutic procedure","volume":"17","author":"Mohammad","year":"2020","journal-title":"J Radiat Res Appl Sci"},{"key":"R8-20250324","doi-asserted-by":"crossref","first-page":"e1018","DOI":"10.1259\/bjr\/28871143","article-title":"Sedation\/anaesthesia in paediatric radiology","volume":"85","author":"Arlachov","year":"2012","journal-title":"Br J Radiol"},{"key":"R9-20250324","doi-asserted-by":"crossref","first-page":"887","DOI":"10.2214\/AJR.08.1351","article-title":"Cumulative radiation exposure and cancer risk estimates in emergency department patients undergoing repeat or multiple CT","volume":"192","author":"Griffey","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"R10-20250324","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1667\/RR0763.1","article-title":"Solid cancer incidence in atomic bomb survivors:1958-1998","volume":"168","author":"Preston","year":"2007","journal-title":"Radiat Res"},{"key":"R11-20250324","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1001\/jamapediatrics.2013.311","article-title":"The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk","volume":"167","author":"Miglioretti","year":"2013","journal-title":"JAMA Pediatr"},{"key":"R12-20250324","first-page":"138","article-title":"National trends in pediatric CT scans in South Korea:A nationwide cohort study","volume":"83","author":"Kim","year":"2022","journal-title":"Taehan Yongsang Uihakhoe Chi"},{"key":"R13-20250324","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours:A retrospective cohort study","volume":"380","author":"Pearce","year":"2012","journal-title":"Lancet"},{"key":"R14-20250324","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00411-014-0580-3","article-title":"Risk of cancer incidence before the age of 15 years after exposure to ionising radiation from computed tomography:Results from a German cohort study","volume":"54","author":"Krille","year":"2015","journal-title":"Radiat Environ Biophys"},{"key":"R15-20250324","doi-asserted-by":"crossref","first-page":"2354","DOI":"10.1038\/bjc.2014.103","article-title":"Paediatric head CT scan and subsequent risk of malignancy and benign brain tumour:A nation-wide population-based cohort study","volume":"110","author":"Huang","year":"2014","journal-title":"Br J Cancer"},{"key":"R16-20250324","doi-asserted-by":"crossref","first-page":"f2360","DOI":"10.1136\/bmj.f2360","article-title":"Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence:Data linkage study of 11 million Australians","volume":"346","author":"Mathews","year":"2013","journal-title":"BMJ"},{"key":"R17-20250324","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1093\/jnci\/djy104","article-title":"Radiation exposure from pediatric CT scans and subsequent cancer risk in the Netherlands","volume":"111","author":"Meulepas","year":"2019","journal-title":"J Natl Cancer Inst"},{"key":"R18-20250324","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography \u2013An increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N Engl J Med"},{"key":"R19-20250324","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1542\/peds.112.4.951","article-title":"Computed tomography and radiation risks:What pediatric health care providers should know","volume":"112","author":"Frush","year":"2003","journal-title":"Pediatrics"},{"key":"R20-20250324","doi-asserted-by":"crossref","first-page":"R129","DOI":"10.1088\/0031-9155\/59\/3\/R129","article-title":"Dose in X-ray computed tomography","volume":"59","author":"Kalender","year":"2014","journal-title":"Phys Med Biol"},{"key":"R23-20250324","first-page":"1","article-title":"Managing patient dose in multi-detector computed tomography(MDCT)","volume":"37","author":"Valentin","year":"2007","journal-title":"ICRP Publication 102. Ann ICRP"},{"key":"R24-20250324","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.radmp.2021.02.001","article-title":"A multi-provincial survey and analysis of radiation doses from paediatric CT","volume":"2","author":"Kang","year":"2021","journal-title":"Radiat Med Prot"},{"key":"R30-20250324","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.ejmp.2020.05.001","article-title":"Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice","volume":"74","author":"Abuhaimed","year":"2020","journal-title":"Phys Med"},{"key":"R33-20250324","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1259\/bjr\/93277434","article-title":"National survey of doses from CT in the UK:2003","volume":"79","author":"Shrimpton","year":"2006","journal-title":"Br J Radiol"},{"key":"R34-20250324","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1186\/s43055-024-01368-y","article-title":"Radiation dose in cardiac CT for preoperative diagnosis of children with congenital heart disease","volume":"55","author":"Shahid","year":"2024","journal-title":"Egypt J Radiol Nucl Med"},{"key":"R35-20250324","doi-asserted-by":"crossref","first-page":"589","DOI":"10.3390\/ijerph13060589","article-title":"BMI, waist circumference reference values for Chinese school-aged children and adolescents","volume":"13","author":"Song","year":"2016","journal-title":"Int J Environ Res Public Health"},{"key":"R37-20250324","doi-asserted-by":"crossref","first-page":"243","DOI":"10.5152\/dir.2018.17450","article-title":"Size-specific dose estimates in chest, abdomen, and pelvis CT examinations of pediatric patients","volume":"24","author":"\u00d6zsoykal","year":"2018","journal-title":"Diagn Interv Radiol"},{"key":"R38-20250324","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.ejmp.2022.09.004","article-title":"Patient size as a parameter for determining diagnostic reference levels for paediatric Computed Tomography (CT) procedures","volume":"102","author":"Satharasinghe","year":"2022","journal-title":"Phys Med"},{"key":"R39-20250324","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1093\/rpd\/ncae104","article-title":"Size specific dose estimation in pediatric CT:Preliminary study and conversion factors","volume":"200","author":"Zhang","year":"2024","journal-title":"Radiat Prot Dosimetry"},{"key":"R40-20250324","doi-asserted-by":"crossref","first-page":"7848","DOI":"10.3390\/app14177848","article-title":"An age-based size-specific dose estimate for pediatric computed tomography head examinations performed at songklanagarind hospital, Thailand, from 2017 to 2019","volume":"14","author":"Poosiri","year":"2024","journal-title":"Appl Sci"},{"key":"R41-20250324","first-page":"118","article-title":"Radiation dose in paediatric computed tomography:Risks and benefits","volume":"8","author":"Ogbole","year":"2010","journal-title":"Ann Ib Postgrad Med"},{"key":"R42-20250324","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1118\/1.597564","article-title":"Energy imparted in computed tomography","volume":"22","author":"Huda","year":"1995","journal-title":"Med Phys"},{"key":"R43-20250324","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0969-8043(98)00021-9","article-title":"Balancing patient dose and image quality","volume":"50","author":"Martin","year":"1999","journal-title":"Appl Radiat Isot"},{"key":"R44-20250324","doi-asserted-by":"crossref","first-page":"266","DOI":"10.4103\/jmp.JMP_91_17","article-title":"A Study to Determine Whether the Volume-Weighted Computed Tomography Dose Index Gives Reasonable Estimates of Organ Doses for Thai Patients Undergoing Abdomen and Pelvis Computed Tomography Examinations","volume":"42","author":"Sookpeng","year":"2017","journal-title":"J Med Phys"},{"key":"R46-20250324","doi-asserted-by":"crossref","first-page":"210","DOI":"10.4103\/jmp.jmp_102_22","article-title":"Multivariate analysis of effective dose and size-specific dose estimates for thorax and abdominal computed tomography","volume":"48","author":"Shah","year":"2023","journal-title":"J Med Phys"},{"key":"R47-20250324","doi-asserted-by":"crossref","first-page":"3111","DOI":"10.1038\/s41591-023-02620-0","article-title":"Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults","volume":"29","author":"Bosch de Basea Gomez","year":"2023","journal-title":"Nat Med"},{"key":"R48-20250324","first-page":"2","article-title":"Size Specific Dose Estimate in Abdominal Computed Tomography by AAPM TG Report- 204 and AAPM TG- 220","volume":"6","author":"Shah","year":"2023","journal-title":"Radiol Med Diagnost Imaging"},{"key":"R50-20250324","doi-asserted-by":"crossref","first-page":"4249","DOI":"10.1118\/1.3460797","article-title":"A method to evaluate the dose increase in CT with iodinated contrast medium","volume":"37","author":"Amato","year":"2010","journal-title":"Med Phys"},{"key":"R51-20250324","first-page":"1","article-title":"Decreasing the radiation dose for contrast-enhanced abdominal spectral CT with a half contrast dose:a matched-pair comparison with a 120 kVp protocol","volume":"2","author":"Sakabe","year":"2020","journal-title":"British Journal of Radiology\/Open"},{"key":"R52-20250324","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1093\/rpd\/ncad133","article-title":"Size-specific dose estimates in pediatric brain CT in relation to age and weight","volume":"199","author":"Fujii","year":"2023","journal-title":"Radiat Prot Dosimetry"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_55_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:55:44Z","timestamp":1786647344000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_55_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_55_24","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2024-03-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}