{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:22:02Z","timestamp":1787761322607,"version":"build-2784847793"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>Assess the interfraction dose variations of the organs at risk (OARs) in carcinoma cervix high dose rate (HDR) computed tomography (CT)-guided intra cavitary brachytherapy (ICBT). 120 CT scans of 40 patients who had undergone three fractions of ICBT (7 Gy\/fr) were analyzed. Dose to Point A and the minimum doses to the volumes of 2, 1, and 0.1cc of bladder, rectum and sigmoid colon were recorded. Revised plans were generated in 20 patients. Paired t-test was used to compare the difference in the means. Point \u201cA\u201d mean dose difference was statistically significant between the treated and revised plans. For bladder, the difference in means of dosage to all volumes, whilst for the rectum and sigmoid colon, the low volume dosage (0.1cc) was statistically significant. Absence of individualized planning would have resulted in underdosage of tumor and increased dosage of up to 30% to OARs. CT-guided ICBT should be implemented for each HDR fraction treatment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_91_22","type":"journal-article","created":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T02:42:19Z","timestamp":1673318539000},"page":"394-397","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Reporting of Inter Fraction Dose Variations of Organs at Risk in Computed Tomography-Guided High Dose Rate Intracavitary Brachytherapy in Carcinoma Cervix"],"prefix":"10.4103","volume":"47","author":[{"given":"Moujhuri","family":"Nandi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neelima","family":"Pokala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vaishnavi","family":"Perumareddy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujata","family":"Sarkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudeep","family":"Chanda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-12-20240906","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1200\/GO.20.00122","article-title":"Cancer statistics, 2020: Report from National Cancer Registry Programme, India","volume":"6","author":"Mathur","year":"2020","journal-title":"JCO Glob Oncol"},{"key":"R2-12-20240906","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1056\/NEJM199904153401502","article-title":"Concurrent cisplatin-based radiotherapy and chemotherapy for locally advanced cervical cancer","volume":"340","author":"Rose","year":"1999","journal-title":"N Engl J Med"},{"key":"R3-12-20240906","doi-asserted-by":"crossref","first-page":"1606","DOI":"10.1200\/JCO.2000.18.8.1606","article-title":"Concurrent chemotherapy and pelvic radiation therapy compared with pelvic radiation therapy alone as adjuvant therapy after radical surgery in high-risk early-stage cancer of the cervix","volume":"18","author":"Peters","year":"2000","journal-title":"J Clin Oncol"},{"key":"R4-12-20240906","first-page":"1","article-title":"National cancer grid of India consensus guidelines on the management of cervical cancer","volume":"4","author":"Chopra","year":"2018","journal-title":"J Glob Oncol"},{"key":"R5-12-20240906","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/0360-3016(91)90143-R","article-title":"Tumor and treatment factors improving outcome in stage III-B cervix cancer","volume":"20","author":"Lanciano","year":"1991","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R6-12-20240906","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/0360-3016(91)90142-Q","article-title":"Patterns and sites of failure in cervix cancer treated in the U.S.A. in 1978","volume":"20","author":"Montana","year":"1991","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R7-12-20240906","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1002\/1097-0142(19830301)51:5<959::AID-CNCR2820510533>3.0.CO;2-K","article-title":"Patterns of care outcome studies. Results of the national practice in cancer of the cervix","volume":"51","author":"Hanks","year":"1983","journal-title":"Cancer"},{"key":"R9-12-20240906","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.ygyno.2014.12.038","article-title":"High versus low-dose rate brachytherapy for cervical cancer","volume":"136","author":"Patankar","year":"2015","journal-title":"Gynecol Oncol"},{"key":"R10-12-20240906","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/0360-3016(96)00187-3","article-title":"Major geometric variations between intracavitary applications in carcinoma of the cervix: High dose rate versus low dose rate","volume":"35","author":"Kim","year":"1996","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R12-12-20240906","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1002\/ijgo.12611","article-title":"Cancer of the cervix uteri","volume":"143","author":"Bhatla","year":"2018","journal-title":"Int J Gynaecol Obstet"},{"key":"R13-12-20240906","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/j.ijrobp.2004.04.032","article-title":"Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: Report from Image-Guided Brachytherapy Working Group","volume":"60","author":"Nag","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R14-12-20240906","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.brachy.2011.07.003","article-title":"American Brachytherapy Society consensus guidelines for locally advanced carcinoma of the cervix. Part I: General principles","volume":"11","author":"Viswanathan","year":"2012","journal-title":"Brachytherapy"},{"key":"R15-12-20240906","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.radonc.2004.12.015","article-title":"Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): Concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV","volume":"74","author":"Haie-Meder","year":"2005","journal-title":"Radiother Oncol"},{"key":"R16-12-20240906","first-page":"687365","article-title":"Magnitude and implications of interfraction variations in organ doses during high dose rate brachytherapy of cervix cancer: A CT based planning study","volume":"2014","author":"Chakraborty","year":"2014","journal-title":"ISRN Oncol"},{"key":"R17-12-20240906","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.brachy.2004.07.001","article-title":"Is simulation necessary for each high-dose-rate tandem and ovoid insertion in carcinoma of the cervix?","volume":"3","author":"Jones","year":"2004","journal-title":"Brachytherapy"},{"key":"R18-12-20240906","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.brachy.2007.12.003","article-title":"Image-guided cervix high-dose-rate brachytherapy treatment planning: Does custom computed tomography planning for each insertion provide better conformal avoidance of organs at risk?","volume":"7","author":"Davidson","year":"2008","journal-title":"Brachytherapy"},{"key":"R19-12-20240906","doi-asserted-by":"crossref","first-page":"136","DOI":"10.4103\/jmp.JMP_136_17","article-title":"Interfraction dose variations in organs at risk during CT-based high-dose-rate brachytherapy in locally advanced carcinoma cervix: An early experience of a tertiary care center","volume":"43","author":"Sharma","year":"2018","journal-title":"J Med Phys"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_91_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:32:18Z","timestamp":1787758338000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_91_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_91_22","relation":{},"ISSN":["0971-6203"],"issn-type":[{"value":"0971-6203","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10]]}}}