{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:35:22Z","timestamp":1786649722546,"version":"build-2736575974"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Context:<\/jats:title>\n                    <jats:p>The minimum segment width (MSW) is a critical element in designing optimal apertures and creating segments of various sizes and shapes in radiation treatment planning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>This study utilized dose-volume histogram analysis to evaluate the effect of MSW on dose distribution in patients undergoing volumetric modulated arc therapy (VMAT) for prostate cancer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>VMAT plans were generated for 13 prostate cancer patients using 6MV photons in the Monaco treatment planning system. The plans were designed with three different MSW: 0.5 cm, 1.0 cm, and 1.5 cm while keeping all remaining factors constant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Subjects and Methods:<\/jats:title>\n                    <jats:p>The plans for each MSW group were compared based on several criteria: conformity index, homogeneity index, dose to organs at risk, control points, monitor units (MUs), plan execution time, and gamma passing rates (GPRs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Comparing the plans with different MSWs revealed that treatment plans using MSWs of 0.5 cm and 1.0 cm were of higher standard compared to those with an MSW of 1.5 cm. Specifically, planning target volume coverage (V95) significantly decreased with the increase to a 1.5 cm MSW. It was also noted that with an increase in MSW, the overall MUs decreased and the GPR improved.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The 0.5 cm and 1.0 cm MSW sets demonstrated superior VMAT plan merit compared to the 1.5 cm MSW set. VMAT plans with a 1.0 cm MSW can be considered the optimal choice, ensuring both high-plan quality and efficient treatment for prostate cases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmp.jmp_9_25","type":"journal-article","created":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T04:01:23Z","timestamp":1751515283000},"page":"312-319","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Enhancing Treatment Efficiency: Investigating the Optimal Segment Width in Volumetric Modulated Arc Therapy for Prostate Cancer Management"],"prefix":"10.4103","volume":"50","author":[{"given":"Gleetus","family":"Thimothy","sequence":"first","affiliation":[{"name":"Department of Physics, Institute of Applied Sciences and Humanities, GLA University, Mathura, Uttar Pradesh, India"},{"name":"Department of Radiation Oncology, Apex Hospital Pvt Ltd., Jaipur, Rajasthan, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary","family":"Joan","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Christian Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anuj","family":"Vijay","sequence":"additional","affiliation":[{"name":"Department of Physics, Institute of Applied Sciences and Humanities, GLA University, Mathura, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,3]]},"reference":[{"key":"R1-20250703","first-page":"146","article-title":"Radiation therapy for prostate cancer","volume":"115","author":"Gay","year":"2018","journal-title":"Mo Med"},{"key":"R2-20250703","first-page":"57","article-title":"Recent advances in radiotherapy modalities for prostate cancer","volume":"61","author":"Murgi\u0107","year":"2022","journal-title":"Acta Clin Croat"},{"key":"R3-20250703","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.hoc.2019.08.005","article-title":"Modern radiation therapy planning and delivery","volume":"33","author":"Gardner","year":"2019","journal-title":"Hematol Oncol Clin North Am"},{"key":"R4-20250703","doi-asserted-by":"crossref","first-page":"158","DOI":"10.4103\/0019-509X.180820","article-title":"Influence of Monte Carlo variance with fluence smoothing in VMAT treatment planning with Monaco TPS","volume":"53","author":"Sarkar","year":"2016","journal-title":"Indian J Cancer"},{"key":"R5-20250703","doi-asserted-by":"crossref","first-page":"89","DOI":"10.3892\/mco.2021.2251","article-title":"VMAT for prostate cancer with 6-MV and 10-MV photons: Impact of beam energy on treatment plan quality and model-based secondary cancer risk estimates","volume":"14","author":"Mazonakis","year":"2021","journal-title":"Mol Clin Oncol"},{"key":"R6-20250703","doi-asserted-by":"crossref","first-page":"355","DOI":"10.12669\/pjms.37.2.2647","article-title":"Volumetric modulated arc therapy (VMAT): A modern radiotherapy technique \u2013 A single institutional experience","volume":"37","author":"Rashid","year":"2021","journal-title":"Pak J Med Sci"},{"key":"R7-20250703","doi-asserted-by":"crossref","first-page":"84","DOI":"10.5505\/tjo.2023.4137","article-title":"Investigating the influence of minimum segment width in volumetric-modulated arc planning of prostate cancer","volume":"39","author":"Jain","year":"2024","journal-title":"Turk J Oncol"},{"key":"R8-20250703","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.rpor.2014.03.003","article-title":"Influence of segment width on plan quality for volumetric modulated arc based stereotactic body radiotherapy","volume":"19","author":"Nithiyanantham","year":"2014","journal-title":"Rep Pract Oncol Radiother"},{"key":"R9-20250703","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1002\/acm2.12422","article-title":"A study of minimum segment width parameter on VMAT plan quality, delivery accuracy, and efficiency for cervical cancer using Monaco TPS","volume":"19","author":"Wang","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"R10-20250703","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/acm2.13417","article-title":"Investigation of optimum minimum segment width on VMAT plan quality and deliverability: A comprehensive dosimetric and clinical evaluation using DVH analysis","volume":"22","author":"Yoosuf","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"R11-20250703","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.meddos.2018.02.005","article-title":"Monaco treatment planning system tools and optimization processes","volume":"43","author":"Clements","year":"2018","journal-title":"Med Dosim"},{"key":"R12-20250703","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/1748-717X-4-3","article-title":"Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions","volume":"4","author":"Wu","year":"2009","journal-title":"Radiat Oncol"},{"issue":"Suppl 3","key":"R13-20250703","first-page":"219","article-title":"A simple scoring ratio to index the conformity of radiosurgical treatment plans","volume":"93","author":"Paddick","year":"2000","journal-title":"Technical note. J Neurosurg"},{"key":"R14-20250703","doi-asserted-by":"crossref","first-page":"5851","DOI":"10.1118\/1.3013556","article-title":"Evaluation of a commercial biologically based IMRT treatment planning system","volume":"35","author":"Semenenko","year":"2008","journal-title":"Med Phys"},{"key":"R15-20250703","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1118\/1.598248","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med Phys"},{"key":"R16-20250703","doi-asserted-by":"crossref","first-page":"5359","DOI":"10.1118\/1.3238104","article-title":"IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM task group 119","volume":"36","author":"Ezzell","year":"2009","journal-title":"Med Phys"},{"key":"R17-20250703","doi-asserted-by":"crossref","first-page":"724","DOI":"10.3938\/jkps.74.724","article-title":"Effect of minimum segment width on gamma passing rate considering MLC position error for volumetric modulated arc therapy","volume":"74","author":"Moon","year":"2019","journal-title":"J Korean Phys Soc"},{"key":"R18-20250703","doi-asserted-by":"crossref","first-page":"9913","DOI":"10.2147\/IJGM.S336269","article-title":"Optimization of minimum segment width parameter in the intensity-modulated radiotherapy plan for esophageal cancer","volume":"14","author":"Hong","year":"2021","journal-title":"Int J Gen Med"},{"key":"R19-20250703","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.radonc.2005.02.007","article-title":"Intensity modulated radiation therapy with multileaf collimators of different leaf widths: A comparison of achievable dose distributions","volume":"75","author":"Nill","year":"2005","journal-title":"Radiother Oncol"},{"key":"R21-20250703","doi-asserted-by":"crossref","first-page":"292","DOI":"10.17511\/ijmrr.2018.i06.01","article-title":"Effect of fluence smoothening in intensity modulated radiotherapy planning and delivery","volume":"6","author":"Reddy","year":"2018","journal-title":"Int J Med Res Rev"},{"key":"R22-20250703","first-page":"148","article-title":"Measurement of radiation doses adjacent to the treated volume in radiotherapy for carcinoma cervix and evaluation of lifetime attributable risk","volume":"4","author":"Joan","year":"2019","journal-title":"Int J Innov Sci Res Tech"}],"container-title":["Journal of Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_9_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:57:37Z","timestamp":1786647457000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmp.jmp_9_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jmp.jmp_9_25","relation":{},"ISSN":["0971-6203","1998-3913"],"issn-type":[{"value":"0971-6203","type":"print"},{"value":"1998-3913","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2025-01-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}