{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:41:12Z","timestamp":1786650072354,"version":"build-2736575974"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>During chest CT examinations, the breasts are exposed to a significant amount of radiation, increasing the risk of radiation-induced cancers. The objective of this study is to develop and evaluate a novel silicon rubber-barium sulfate (BaSO4) composite breast shield for reducing radiation dose in chest computed tomography (CT) examinations while minimizing impact on image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Four breast shields were fabricated: one with 10% bismuth and three with 10%, 15%, and 20% BaSO4. Dose reduction was assessed using a thorax phantom and ionization chamber. Image quality effects were evaluated in the thorax phantom by measuring noise and CT number changes. The 10% barium shield was further tested on 22 patients undergoing chest CT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The 10%, 15%, and 20% barium shields reduced breast dose by 36.8%, 38.6%, and 45.6%, respectively, while the 10% bismuth shield achieved a 63.1% reduction. However, the 10% barium shield had minimal impact on image quality, increasing lung noise by only 0.3 Hounsfield units (HU) and shifting CT numbers by 4.7 HU. In patient studies, 81.8% of scans showed no artifacts, with 18.2% showing slight artifacts.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The 10% BaSO4 shield effectively reduced breast dose while maintaining image quality, presenting a viable alternative to bismuth shielding for radiation protection in chest CT examinations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmss.jmss_61_24","type":"journal-article","created":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T10:00:10Z","timestamp":1752228010000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Balancing Radiation Dose Reduction and Image Quality in Chest Computed Tomography using Silicon Rubber-barium Sulfate Composite Shield"],"prefix":"10.4103","volume":"15","author":[{"given":"Mohammad","family":"Keshtkar","sequence":"first","affiliation":[{"name":"Department of Medical Physics and Radiology, Infectious Diseases Research Centre, Faculty of Medicine, Gonabad University of Medical Sciences, Gonabad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saeedeh","family":"Yazdanifar","sequence":"additional","affiliation":[{"name":"Student Research Committee, Gonabad University of Medical Sciences, Gonabad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7]]},"reference":[{"key":"R2-20250711","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1007\/s11547-019-01034-8","article-title":"Protecting sensitive patient groups from imaging using ionizing radiation: Effects during pregnancy, in fetal life and childhood","volume":"124","author":"Tom\u00e0","year":"2019","journal-title":"Radiol Med"},{"key":"R3-20250711","doi-asserted-by":"crossref","first-page":"110452","DOI":"10.1016\/j.apradiso.2022.110452","article-title":"Assessment of breast dose and cancer risk for young females during CT chest and abdomen examinations","volume":"190","author":"Tamam","year":"2022","journal-title":"Appl Radiat Isot"},{"key":"R4-20250711","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1093\/rpd\/ncx283","article-title":"Estimation of female radiation doses and breast cancer risk from chest CT examinations","volume":"179","author":"Lahham","year":"2018","journal-title":"Radiat Prot Dosimetry"},{"key":"R5-20250711","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.ejrad.2018.11.002","article-title":"Vendor free basics of radiation dose reduction techniques for CT","volume":"110","author":"Kubo","year":"2019","journal-title":"Eur J Radiol"},{"key":"R6-20250711","first-page":"341","article-title":"Application of different methods for reducing radiation dose to breast during MDCT","volume":"8","author":"Keshtkar","year":"2018","journal-title":"J Biomed Phys Eng"},{"key":"R7-20250711","doi-asserted-by":"crossref","first-page":"041503","DOI":"10.1088\/1361-6498\/acffd4","article-title":"Assessment of the effectiveness of Saba shielding with the composition of Cu\u2013Bi in neck CT imaging: A phantom and patient study","volume":"43","author":"Keshtkar","year":"2023","journal-title":"J Radiol Prot"},{"key":"R8-20250711","doi-asserted-by":"crossref","first-page":"109425","DOI":"10.1016\/j.radphyschem.2021.109425","article-title":"Feasibility of polymer-based composite materials as radiation shield","volume":"183","author":"Almurayshid","year":"2021","journal-title":"Radiat Phys Chem"},{"key":"R9-20250711","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1007\/s00411-020-00865-8","article-title":"Shielding characteristics of nanocomposites for protection against X- and gamma rays in medical applications: Effect of particle size, photon energy and nano-particle concentration","volume":"59","author":"Mansouri","year":"2020","journal-title":"Radiat Environ Biophys"},{"key":"R10-20250711","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s41365-018-0459-0","article-title":"Preparation and characterization of iron-ore-imbedded silicone rubber materials for radiation protection","volume":"29","author":"Buyuk","year":"2018","journal-title":"Nucl Sci Tech"},{"key":"R11-20250711","doi-asserted-by":"crossref","first-page":"e96002","DOI":"10.5812\/iranjradiol.96002","article-title":"Assessment of the effect of nano-composite shield on radiation risk prevention to Breast during computed tomography","volume":"17","author":"Mehnati","year":"2020","journal-title":"Iran J Radiol"},{"key":"R12-20250711","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1080\/10420150.2020.1849213","article-title":"Evaluation of radiation dose reduction by barium composite shielding in an angiography system","volume":"176","author":"Lee","year":"2021","journal-title":"Radiat Eff Defects Solids"},{"key":"R13-20250711","doi-asserted-by":"crossref","first-page":"e84158","DOI":"10.5812\/ijcm.84158","article-title":"The Effect of Contrast-enhanced Computed Tomography (CT) Scans on the Calculated Dose of Radiotherapy in a Thorax Phantom","volume":"14","author":"Ehtiati","year":"2021","journal-title":"Int J Cancer Manag"},{"key":"R14-20250711","doi-asserted-by":"crossref","first-page":"025006","DOI":"10.1088\/2057-1976\/acb551","article-title":"Evaluation of silicone rubber-lead shield's effectiveness in protecting the breast during thoracic CT","volume":"9","author":"Lestari","year":"2023","journal-title":"Biomed Phys Eng Express"},{"key":"R15-20250711","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.ejmp.2019.05.013","article-title":"Targeted radiation energy modulation using Saba shielding reduces breast dose without degrading image quality during thoracic CT examinations","volume":"65","author":"Saba","year":"2019","journal-title":"Phys Med"},{"key":"R16-20250711","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1080\/10420150.2020.1768391","article-title":"Assessment of dose reduction and image quality by barium composite shielding in head and chest CT","volume":"175","author":"Lee","year":"2020","journal-title":"Radiat Eff Defects Solids"},{"key":"R17-20250711","doi-asserted-by":"crossref","first-page":"e26277","DOI":"10.1097\/MD.0000000000026277","article-title":"Bismuth breast-shield use in chest computed tomography for efficient dose reduction and sufficient image quality","volume":"100","author":"Ko","year":"2021","journal-title":"Medicine (Baltimore)"},{"key":"R18-20250711","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.radi.2020.04.011","article-title":"Organ-based tube current modulation in chest CT. A comparison of three vendors","volume":"27","author":"Mussmann","year":"2021","journal-title":"Radiography (Lond)"},{"key":"R19-20250711","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1093\/rpd\/ncy242","article-title":"Comparison of organ-based tube current modulation and bismuth shielding in chest CT: Effect on the image quality and the patient dose","volume":"185","author":"Kotiaho","year":"2019","journal-title":"Radiat Prot Dosimetry"}],"container-title":["Journal of Medical Signals &amp; Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmss.jmss_61_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:01:45Z","timestamp":1786647705000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmss.jmss_61_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":18,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/jmss.jmss_61_24","relation":{},"ISSN":["2228-7477"],"issn-type":[{"value":"2228-7477","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"2024-09-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}